Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Crit Care ; 83: 154843, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38875914

RESUMO

PURPOSE: Mortality is often assessed during ICU stay and early after, but rarely at later stage. We aimed to compare the long-term mortality between TBI and ICH patients. MATERIALS AND METHODS: From an observational cohort, we studied 580 TBI patients and 435 ICH patients, admitted from January 2013 to February 2021 in 3 ICUs and alive at 7-days post-ICU discharge. We performed a Lasso-penalized Cox survival analysis. RESULTS: We estimated 7-year survival rates at 72.8% (95%CI from 67.3% to 78.7%) for ICH patients and at 84.9% (95%CI from 80.9% to 89.1%) for TBI patients: ICH patients presenting a higher mortality risk than TBI patients. Additionally, we identified variables associated with higher mortality risk (age, ICU length of stay, tracheostomy, low GCS, absence of intracranial pressure monitoring). We also observed anisocoria related with the mortality risk in the early stage after ICU stay. CONCLUSIONS: In this ICU survivor population with a prolonged follow-up, we highlight an acute risk of death after ICU stay, which seems to last longer in ICH patients. Several variables characteristic of disease severity appeared associated with long-term mortality, raising the hypothesis that the most severe patients deserve closer follow-up after ICU stay.

2.
Clin Microbiol Infect ; 26(10): 1415.e1-1415.e4, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32437956

RESUMO

OBJECTIVES: To assess the meningeal penetration of cefazolin and cloxacillin in individuals treated for methicillin-susceptible staphylococcal meningitis. METHODS: We retrospectively identified individuals treated for Staphylococcus meningitis with measurements of cefazolin or cloxacillin concentrations in cerebrospinal fluid (CSF) using a validated assay of liquid chromatography coupled with mass spectrometry at the Nantes University Hospital between January 2009 and October 2019. Staphylococcus meningitis was defined by a compatible clinical presentation and a microbiological confirmation (positive CSF culture or positive specific PCR). Medical charts were retrospectively reviewed to collect microbiological and clinical data, and to assess therapeutic success. RESULTS: Among the 17 included individuals, eight (47%) were treated with cefazolin and nine (53%) with cloxacillin. Median daily dosages of cefazolin and cloxacillin were 8 g (range 6-12 g) and 12 g (range 10-13 g), respectively. Cefazolin and cloxacillin were mainly administered by continuous infusion. Eleven individuals (65%) were men, median (interquartile range (IQR)) age was 54 years (50; 70), 14 (82%) had postoperative meningitis and 3 (18%) had haematogenous meningitis. Median (IQR) antibiotic CSF concentrations were 2.8 mg/L (2.1; 5.2) and 0.66 mg/L (0.5; 0.9) for cefazolin and cloxacillin groups, respectively. Cloxacillin was discontinued in two individuals for therapeutic failure. CONCLUSIONS: Patients with staphylococcal meningitis treated with high-dose continuous intravenous infusion of cefazolin achieved therapeutic concentrations in CSF. Cefazolin appears to be a therapeutic candidate that should be properly evaluated in this indication.


Assuntos
Antibacterianos/líquido cefalorraquidiano , Cefazolina/líquido cefalorraquidiano , Cloxacilina/líquido cefalorraquidiano , Meningites Bacterianas/tratamento farmacológico , Infecções Estafilocócicas/tratamento farmacológico , Idoso , Antibacterianos/uso terapêutico , Cefazolina/uso terapêutico , Cromatografia Líquida , Cloxacilina/uso terapêutico , Feminino , Humanos , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Estudos Retrospectivos , Staphylococcus aureus/efeitos dos fármacos
3.
Br J Anaesth ; 118(3): 355-362, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28186263

RESUMO

Background: During fluid challenge, volume expansion (VE)-induced increase in cardiac output (Δ VE CO) is seldom measured. Methods: In patients with shock undergoing strictly controlled mechanical ventilation and receiving VE, we assessed minimally invasive surrogates for Δ VE CO (by transthoracic echocardiography): fluid-induced increases in end-tidal carbon dioxide (Δ VE E'CO2 ); pulse (Δ VE PP), systolic (Δ VE SBP), and mean systemic blood pressure (Δ VE MBP); and femoral artery Doppler flow (Δ VE FemFlow). In the absence of arrhythmia, fluid-induced decrease in heart rate (Δ VE HR) and in pulse pressure respiratory variation (Δ VE PPV) were also evaluated. Areas under the receiver operating characteristic curves (AUC ROC s) reflect the ability to identify a response to VE (Δ VE CO ≥15%). Results: In 86 patients, Δ VE E'CO2 had an AUC ROC =0.82 [interquartile range 0.73-0.90], significantly higher than the AUC ROC for Δ VE PP, Δ VE SBP, Δ VE MBP, and Δ VE FemFlow (AUC ROC =0.61-0.65, all P <0.05). A value of Δ VE E'CO2 >1 mm Hg (>0.13 kPa) had good positive (5.0 [2.6-9.8]) and fair negative (0.29 [0.2-0.5]) likelihood ratios. The 16 patients with arrhythmia had similar relationships between Δ VE E'CO2 and Δ VE CO to patients with regular rhythm ( r 2 =0.23 in both subgroups). In 60 patients with no arrhythmia, Δ VE E'CO2 (AUC ROC =0.84 [0.72-0.92]) outperformed Δ VE HR (AUC ROC =0.52 [0.39-0.66], P <0.05) and tended to outperform Δ VE PPV (AUC ROC =0.73 [0.60-0.84], P =0.21). In the 45 patients with no arrhythmia and receiving ventilation with tidal volume <8 ml kg -1 , Δ VE E'CO2 performed better than Δ VE PPV, with AUC ROC =0.86 [0.72-0.95] vs 0.66 [0.49-0.80], P =0.02. Conclusions: Δ VE E'CO2 outperformed Δ VE PP, Δ VE SBP, Δ VE MBP, Δ VE FemFlow, and Δ VE HR and, during protective ventilation, arrhythmia, or both, it also outperformed Δ VE PPV. A value of Δ VE E'CO2 >1 mm Hg (>0.13 kPa) indicated a likely response to VE.


Assuntos
Dióxido de Carbono/metabolismo , Baixo Débito Cardíaco/diagnóstico , Baixo Débito Cardíaco/metabolismo , Ecocardiografia/métodos , Hidratação , Idoso , Baixo Débito Cardíaco/fisiopatologia , Cuidados Críticos/métodos , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Respiração Artificial , Volume de Ventilação Pulmonar
5.
Vox Sang ; 111(2): 151-60, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27240119

RESUMO

BACKGROUND: This study hypothesized that the relationship between early coagulopathy and massive transfusion (MT) in trauma was highly dependent on the presence of surgical bleeding. METHODS: Consecutive severe trauma patients admitted to our institution over a 4-year period were included in this retrospective study. Surgical bleeding was defined as an injury requiring an invasive endovascular or surgical haemostatic procedure. The ability of prothrombin time ratio (PTr) and activated partial thromboplastin time ratio (aPTTr) to predict MT (≥10 units of packed red blood cells during the first 24 h) was determined by ROC curves. The strength of association and interaction between PTr, surgical bleeding and MT was assessed using a logistic regression analysis. RESULTS: Among the 704 patients included (ISS 21·0 ± 16·2), MT rate was higher in patients with surgical bleeding than in those with no surgical bleeding (47% vs. 5%; P < 0·001). The global performance of PTr and aPTTr to predict MT was only fair in our study population (AUCs 0·83 and 0·81). MT rate was widely higher in the surgical bleeding group whatever the severity of coagulopathy (P < 0·001). PTr was found to be significantly associated with TM [PTr ≥ 1·5, OR 23·6 (95% CI 13·4-41·7); PTr 1·2-1·5, OR 3·0 (95% CI 1·7-5·3)]. Corresponding ORs were reduced after adjusting for the surgical bleeding: 12·1 (95% CI 6·5-22·5) and 2·1 (95% CI 1·2-4·0), respectively. However, no significant interaction was found regression models. CONCLUSION: The strength of association between MT and coagulation status on admission was found strongly influenced by surgical bleeding. The admission coagulopathy monitoring in trauma patients without considering the surgical bleeding does not allow a reliable determination of MT probability.


Assuntos
Transtornos da Coagulação Sanguínea/etiologia , Perda Sanguínea Cirúrgica , Ferimentos e Lesões/patologia , Adolescente , Adulto , Área Sob a Curva , Transfusão de Sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Tempo de Tromboplastina Parcial , Curva ROC , Estudos Retrospectivos , Risco , Adulto Jovem
6.
Br J Anaesth ; 115(4): 540-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26385663

RESUMO

BACKGROUND: Since arrhythmia induces irregular pulse waves, it is widely considered to cause flawed oscillometric brachial cuff measurements of blood pressure (BP). However, strong data are lacking. We assessed whether the agreement of oscillometric measurements with intra-arterial measurements is worse during arrhythmia than during regular rhythm. METHODS: Among patients of three intensive care units (ICUs), a prospective comparison of three pairs of intra-arterial and oscillometric BP readings was performed among patients with arrhythmia and an arterial line already present. After each inclusion in the arrhythmia group, one patient with regular rhythm was included as a control. International Organization for Standardization (ISO) standard validation required a mean bias <5 (sd 8) mm Hg. RESULTS: In 135 patients with arrhythmia, the agreement between oscillometric and intra-arterial measurements of systolic, diastolic and mean BP was similar to that observed in 136 patients with regular rhythm: for mean BP, similar mean bias [-0.1 (sd 5.2) and 1.9 (sd 5.9) mm Hg]. In both groups, the ISO standard was satisfied for mean and diastolic BP, but not for systolic BP (sd >10 mm Hg) in our ICU population. The ability of oscillometry to detect hypotension (systolic BP <90 mm Hg or mean BP <65 mm Hg), response to therapy (>10% increase in mean BP after cardiovascular intervention) and hypertension (systolic BP >140 mm Hg) was good and similar during arrhythmia and regular rhythm (respective areas under the receiver operating characteristic curves ranging from 0.89 to 0.96, arrhythmia vs regular rhythm between-group comparisons all associated with P>0.3). CONCLUSIONS: Contrary to widespread belief, arrhythmia did not cause flawed automated brachial cuff measurements.


Assuntos
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Monitores de Pressão Arterial , Pressão Sanguínea/fisiologia , Idoso , Determinação da Pressão Arterial/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Estudos Prospectivos
7.
Injury ; 45(1): 88-94, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22769979

RESUMO

BACKGROUND: We hypothesised that in blunt trauma patients with haemodynamic instability and haemoperitoneum on hospital admission, the haemorrhagic source may not be confined to the peritoneum. The purpose of this study was to describe the incidence and location of bleeding source in this population. METHODS: The charts of trauma patients admitted consecutively between January 2005 and January 2010 to our level I Regional Trauma Centre were reviewed retrospectively. All hypotensive patients presenting a haemoperitoneum on admission were included. Hypotension was defined by a systolic blood pressure ≤ 90 mmHg. The haemoperitoneum was quantified on CT images or from operative reports as moderate (Federle score<3 or between 200 and 500 ml) or large (Federle score ≥ 3 or >500 ml). Active bleeding (AB) was defined as injury requiring a surgical or radiologic haemostatic procedure, regardless of origin (peritoneal (PAB) or extraperitoneal (EPAB)). RESULTS: Of 1079 patients admitted for severe trauma, 110 patients met the inclusion criteria. Seventy-eight (71%) were male, mean age 35.3 (SD 19) years and mean ISS 36.5 (SD 20.5). Among the 91 patients who had AB, 37 patients (41%) had PAB, 34 (37%) had EPAB and 20 had both (22%). Forty-eight (53%) of them had moderate haemoperitoneum and 43 (47%) had large haemoperitoneum. A large haemoperitoneum had positive predictive value for PAB of 88% (95% CI 75-95%) and negative predictive value of 65% (95% CI 49-79%). The corresponding values in the subgroup of patients with EPAB were 65% (95% CI 38-86%) and 76% (95% CI 59-88%). CONCLUSION: Haemoperitoneum was associated with PAB in only 52% of hypotensive blunt trauma patients and 63% of bleeding patients. In contrast, 59% of bleeding patients had at least one EPAB. The screening of a haemoperitoneum as a marker of active haemorrhagic source may be confusing and lead to misdiagnosis and inappropriate strategy. Clinician should exclude carefully the presence of any EPAB explaining haemorrhagic shock, before to decide haemostatic treatment.


Assuntos
Traumatismos Abdominais/diagnóstico por imagem , Erros de Diagnóstico/prevenção & controle , Hemoperitônio/diagnóstico por imagem , Hemostáticos/administração & dosagem , Hipotensão/etiologia , Peritônio/patologia , Tomografia Computadorizada por Raios X , Ferimentos não Penetrantes/diagnóstico por imagem , Traumatismos Abdominais/complicações , Traumatismos Abdominais/terapia , Adulto , Feminino , Hemoperitônio/etiologia , Hemoperitônio/terapia , Humanos , Escala de Gravidade do Ferimento , Masculino , Guias de Prática Clínica como Assunto , Valor Preditivo dos Testes , Estudos Retrospectivos , Centros de Traumatologia , Ferimentos não Penetrantes/complicações , Ferimentos não Penetrantes/terapia
9.
Ann Fr Anesth Reanim ; 31(5): e67-72, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22464162

RESUMO

OBJECTIVE: The passive leg raising maneuver (PLR) for fluid responsiveness testing relies on cardiac output (CO) measurements or invasive measurements of arterial pressure (AP) whereas the initial hemodynamic management during shock is often based solely on brachial cuff measurements. We assessed PLR-induced changes in noninvasive oscillometric readings to predict fluid responsiveness. STUDY DESIGN: Multicentre interventional study. PATIENTS AND METHODS: In ICU sedated patients with circulatory failure, AP (invasive and noninvasive readings) and CO measurements were performed before, during PLR (trunk supine, not modified) and after 500-mL volume expansion. Areas under the ROC curves (AUC) were determined for fluid responsiveness (>10% volume expansion-induced increase in CO) prediction. RESULTS: In 112 patients (19% with arrhythmia), changes in noninvasive systolic AP during PLR (noninvasiveΔ(PLR)SAP) only predicted fluid responsiveness (cutoff 17%, n=21, positive likelihood ratio [LR] of 26 [18-38]), not unresponsiveness. If PLR-induced change in central venous pressure (CVP) was at least of 2 mm Hg (n=60), suggesting that PLR succeeded in altering cardiac preload, noninvasiveΔ(PLR)SAP performance was good: AUC of 0.94 [0.85-0.98], positive and negative LRs of 5.7 [4.6-6.8] and 0.07 [0.009-0.5], respectively, for a cutoff of 9%. Of note, invasive AP-derived indices did not outperform noninvasiveΔ(PLR)SAP. CONCLUSION: Regardless of CVP (i.e., during "blind PLR"), noninvasiveΔ(PLR)SAP more than 17% reliably identified fluid responders. During "CVP-guided PLR", in case of sufficient change in CVP, noninvasiveΔ(PLR)SAP performed better (cutoff of 9%). These findings, in sedated patients who had already undergone volume expansion and/or catecholamines, have to be verified during the early phase of circulatory failure (before an arterial line and/or a CO measuring device is placed).


Assuntos
Determinação da Pressão Arterial/métodos , Pressão Sanguínea/fisiologia , Hidratação/métodos , Perna (Membro)/fisiologia , Idoso , Área Sob a Curva , Arritmias Cardíacas/complicações , Arritmias Cardíacas/terapia , Débito Cardíaco/fisiologia , Pressão Venosa Central/fisiologia , Cuidados Críticos , Feminino , Hemodinâmica/fisiologia , Humanos , Perna (Membro)/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Postura/fisiologia , Valor Preditivo dos Testes , Curva ROC , Fluxo Sanguíneo Regional/fisiologia , Choque/diagnóstico , Choque/terapia
10.
Br J Anaesth ; 108(1): 100-7, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22021899

RESUMO

BACKGROUND: Volume expansion (VE) in neonates or infants during volatile anaesthesia may lead to fluid overload if inappropriate. Transoesophageal Doppler (TED), a non-invasive cardiac output monitoring technique, can provide a comprehensive estimation of the volaemic status. We evaluated whether intraoperative TED-derived parameters can predict volume responsiveness. METHODS: Neonates and infants under general anaesthesia without myocardial dysfunction were prospectively included when the attending anaesthetist, blinded to TED measurements, decided to provide VE based on clinical appreciation and standard monitoring data. Standard and TED-derived data were recorded before and after VE. After VE, patients were classified as responders and non-responders, if their indexed stroke volume (iSV) increased by more than 15% or not, respectively. The attending anaesthetist assessment of VE responsiveness was recorded at the end of VE. RESULTS: Fifty patients aged 42 (4) post-conceptional weeks were included, among which 26 (52%) were responders. Baseline iSV was the only parameter associated with VE responsiveness. Baseline iSV was fairly correlated with VE-induced changes in iSV (ρ=-0.64) and was associated with an area under the receiver operating characteristic curve of 0.90 (0.80, 0.99). Using a cut-off of 25 ml m(-2), baseline iSV predicted volume responsiveness with a sensitivity of 92% and a specificity of 83%. Attending anaesthetists' assessment of VE effectiveness agreed only moderately with TED measurements of iSV changes. CONCLUSIONS: TED-derived iSV measurement during volatile anaesthesia is useful to predict and follow VE responsiveness in neonates and infants without myocardial dysfunction.


Assuntos
Ecocardiografia Transesofagiana , Hidratação/métodos , Substitutos do Plasma/uso terapêutico , Anestesia , Área Sob a Curva , Débito Cardíaco/fisiologia , Interpretação Estatística de Dados , Feminino , Hemodinâmica/efeitos dos fármacos , Hemodinâmica/fisiologia , Humanos , Lactente , Recém-Nascido , Masculino , Monitorização Intraoperatória , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Volume Sistólico/fisiologia , Resultado do Tratamento
11.
Ann Fr Anesth Reanim ; 30(7-8): e1-3, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21680134

RESUMO

Povidone iodine (PI), a skin antiseptic, is sometimes used internally but this procedure exposes to potentially lethal iodine absorption. Indeed, a 41-year-old woman, with no relevant medical history, developed a transient hypotension, anuric renal failure, hemolysis, coagulopathy and uterine infarction after intra-uterine injection of PI as a dye to check the fallopian tube patency (hydrotubation). Iodemia peaked at 6929 µg/dL (normal range 3.4-8.0 µg/dL), and decreased over the 9 days of renal replacement therapy. Extreme caution should be exercised when PI is in contact with a mucosa, the early recognition of iodine toxicity being of utmost importance to rapidly prompt renal replacement therapy. The main purpose of this report is to highlight the clinical features of PI absorption, whatever the route of administration.


Assuntos
Corantes/metabolismo , Corantes/intoxicação , Povidona-Iodo/metabolismo , Povidona-Iodo/intoxicação , Absorção , Adulto , Feminino , Humanos
12.
Int J Clin Pharmacol Ther ; 48(1): 79-83, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20040343

RESUMO

BACKGROUND: Bromazepam intoxication is very common but surprisingly rarely reported. CASE DESCRIPTION: We describe the case of a 73-year-old woman who suffered from a prolonged coma after acute self poisoning with bromazepam (serum concentration of 2,000 ng/ml at admission, 2 - 10 hours after ingestion of up to 180 mg) and zolpidem (900 ng/ml at admission). Only the former lasted at toxic concentrations. Recovery of consciousness allowed extubation on Day 16. Repeat-dose activated charcoal (25 g every 6 h from Day 14 to 16) resulted in minimal effects on bromazepam grossly estimated kinetics. CONCLUSION: Despite its relatively low theoretic half-life, bromazepam may induce a prolonged life-threatening coma, even in the absence of renal or hepatic failure.


Assuntos
Ansiolíticos/intoxicação , Bromazepam/intoxicação , Coma/induzido quimicamente , Idoso , Ansiolíticos/farmacocinética , Antídotos/uso terapêutico , Bromazepam/farmacocinética , Carvão Vegetal/uso terapêutico , Overdose de Drogas , Feminino , Meia-Vida , Humanos , Hipnóticos e Sedativos/farmacocinética , Hipnóticos e Sedativos/intoxicação , Piridinas/farmacocinética , Piridinas/intoxicação , Fatores de Tempo , Zolpidem
13.
Anaesthesia ; 63(8): 876-9, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18518867

RESUMO

Autoimmune thyroxicosis and myasthenia gravis are often associated. In both diseases, clinical features may include neuromuscular weakness, making their distinction challenging. We report a patient with known Graves disease who presented with generalised fatigue, initially attributed solely to thyrotoxicosis, and who experienced severe respiratory failure linked to associated myasthenia gravis that was unmasked by medication used in the perioperative management of his thyroxicosis. Anaesthetists should always consider myasthenia gravis in cases of hyperthyroidism presenting with neuromuscular features.


Assuntos
Doença de Graves/complicações , Miastenia Gravis/complicações , Miastenia Gravis/diagnóstico , Tireotoxicose/complicações , Adulto , Antitireóideos/efeitos adversos , Doenças Autoimunes/diagnóstico , Diagnóstico Diferencial , Glucocorticoides/efeitos adversos , Humanos , Masculino , Debilidade Muscular/diagnóstico , Debilidade Muscular/etiologia , Assistência Perioperatória/efeitos adversos , Insuficiência Respiratória/etiologia , Tireotoxicose/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...