RESUMO
PURPOSE: To examine the optimum time at which fluorescein patterns of gas permeable lenses (GPs) should be evaluated. METHODS: Aligned, 0.2mm steep and 0.2mm flat GPs were fitted to 17 patients (aged 20.6 ± 1.1 years, 10 male). Fluorescein was applied to their upper temporal bulbar conjunctiva with a moistened fluorescein strip. Digital slit lamp images (CSO, Italy) at 10× magnification of the fluorescein pattern viewed with blue light through a yellow filter were captured every 15s. Fluorescein intensity in central, mid peripheral and edge regions of the superior, inferior, temporal and nasal quadrants of the lens were graded subjectively using a +2 to -2 scale and using ImageJ software on the simultaneously captured images. RESULTS: Subjectively graded and objectively image analysed fluorescein intensity changed with time (p < 0.001), lens region (centre, mid-periphery and edge: p < 0.05) and there was interaction between lens region with lens fit (p < 0.001). For edge band width, there was a significant effect of time (F = 118.503, p < 0.001) and lens fit (F = 5.1249, p = 0.012). The expected alignment, flat and steep fitting patterns could be seen from approximately after 30 to 180 s subjectively and 15 to 105 s in captured images. CONCLUSION: Although the stability of fluorescein intensity can start to decline in as little as 45 s post fluorescein instillation, the diagnostic pattern of alignment, steep or flat fit is seen in each meridian by subjective observation from about 30s to 3 min indicating this is the most appropriate time window to evaluate GP lenses in clinical practice.