Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Emerg Med ; 17(1): 12, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38287263

RESUMO

BACKGROUND: Endotracheal intubation is an essential resuscitative procedure in the emergency setting. Airway assessment parameters such as the Mallampati classification are difficult to perform in an emergency setting. As point-of-care ultrasound (POCUS) assessment of airway parameters does not require patients to perform any mandatory action, ultrasound may become the potential first-line noninvasive airway assessment tool in the emergency department (ED). The use of POCUS in the ED has not been sufficiently studied. Using POCUS in airway assessment for predicting difficult intubation may be the next step in successful airway management. METHODOLOGY: The study was an observational study conducted at the ED of the All India Institute of Medical Sciences (Rishikesh). The treating emergency physician recorded the patient history and systemic examination along with an indication for intubation. The POCUS assessment of airway parameters pre-epiglottis to epiglottic vocal cord ratio (Pre-E/E-VC), tongue thickness, hyomental distance, and distance from skin to the hyoid bone was performed by the study investigator. During laryngoscopy, Cormack-Lehane (CL) grading was assessed. The data was entered and analyzed. RESULTS: Seventy patients who required intubation in the ED were enrolled in the study. Among the study population, 48.6%, 28.6%, 14.3%, 1.4%, and 7.1% were classified with the following CL grading: 1, 2a, 2b, 3a, and 3b, respectively. At a cutoff of ≥ 1.86, Pre-E/E-VC predicts difficult laryngoscopy (AUC 0.835) with a sensitivity of 83% and a specificity of 94%. At a cutoff of ≥ 5.98 cm, tongue thickness predicts difficult laryngoscopy (AUC 0.78) with a sensitivity of 83% and a specificity of 88%. At a cutoff of hyomental distance ≤ 6 cm, it predicts difficult laryngoscopy with a sensitivity of 83% and a specificity of 88%. All parameters can act as a promising tool for predicting difficult laryngoscopy, with the single best parameter being Pre-E/E-VC. CONCLUSION: Assessment of the airway with POCUS may be helpful to the emergency physician when the clinical airway assessment parameters fail to predict difficult laryngoscopy as most patients requiring intubation are uncooperative. Assessment of the parameters in our study Pre-E/E-VC, tongue thickness, and hyomental distance can act as a promising tool for predicting difficult laryngoscopy in the emergency scenario.

2.
BMC Emerg Med ; 23(1): 111, 2023 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-37735359

RESUMO

BACKGROUND: One significant cause of morbidity and mortality in patients undergoing endotracheal intubation is the aspiration of gastric contents. Its prevalence is more in the emergency than in elective settings. Point-of-care gastric ultrasound (GUS) is a non-invasive bedside ultrasonogram that provides both qualitative and quantitative information about the stomach contents. The diagnostic accuracy of GUS in terms of gastric parameters (measured antral diameters, antral cross-sectional area, and calculated gastric volume) to predict aspiration is yet unknown. We aim to determine this in the patients undergoing urgent emergency intubation (UEI) in the emergency department. METHODOLOGY: A prospective observational study was conducted at the emergency department of a tertiary healthcare center in India. Patients requiring UEI were identified and a bedside gastric ultrasound was done in the right lateral decubitus position using low frequency curved array probe. The qualitative data and the antral diameters (anteroposterior and craniocaudal) were assessed. The patient's clinical parameters and history regarding the last meal were noted. The cross-sectional area of gastric antrum was calculated using CSA = (AP × CC) π/4. The gastric volume is estimated using Perla's formula: GV = 27.0 + 14.6(RLD CSA) -1.28(age). RESULTS: A hundred patients requiring urgent endotracheal intubation were enrolled in the study. Visible aspiration was more in participants with a distended gastric status (χ2 = 16.880, p = < 0.001). The median gastric volume in the patients who aspirated was 146.37 mL, and it ranged from 111.59 mL-201.01 mL. Using ROC analysis, a cut-off of CC diameter ≥ 2.35 cm (sensitivity 88%, specificity 91%) and AP diameter ≥ 5.15 cm (sensitivity 88%, specificity 87%) predicts aspiration. A calculated USG CSA cut-off ≥ 9.27cm2 (sensitivity 100%, specificity 87%) and an USG gastric volume ≥ 111.594 mL (sensitivity 100%, a specificity 92%) predicts aspiration. CONCLUSION: Point-of-care gastric ultrasound is an useful non-invasive bedside tool for risk stratification for aspiration in busy emergency rooms. We present threshold gastric antral parameters that can be used to predict aspiration along with its diagnostic accuracy. This can help the treating ED physician take adequate precautions, decide on intubation techniques and treatment modifications to aid in better patient management.


Assuntos
Medicina de Emergência , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Intubação Intratraqueal , Confiabilidade dos Dados , Serviço Hospitalar de Emergência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...