1.
Phys Med Biol ; 51(22): 5809-24, 2006 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-17068366

RESUMO

Nonlinear propagation has been demonstrated to have a significant impact on ultrasound imaging. An efficient computational algorithm is presented to simulate nonlinear ultrasound propagation through layered liquid and tissue-equivalent media. Results are compared with hydrophone measurements. This study was undertaken to investigate the role of nonlinear propagation in high frequency ultrasound micro-imaging. The acoustic field of a focused transducer (20 MHz centre frequency, f-number 2.5) was simulated for layered media consisting of water and tissue-mimicking phantom, for several wide-bandwidth source pulses. The simulation model accounted for the effects of diffraction, attenuation and nonlinearity, with transmission and refraction at layer boundaries. The parameter of nonlinearity, B/A, of the water and tissue-mimicking phantom were assumed to be 5.2 and 7.4, respectively. The experimentally measured phantom B/A value found using a finite-amplitude insert-substitution method was shown to be 7.4 +/- 0.6. Relative amounts of measured second and third harmonic pressures as a function of the fundamental pressures at the focus were in good agreement with simulations. Agreement within 3% was found between measurements and simulations of the beam widths of the fundamental and second harmonic signals following propagation through the tissue phantom. The results demonstrate significant nonlinear propagation effects for high frequency imaging beams.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Modelos Biológicos , Radiometria/métodos , Ultrassom , Ultrassonografia/métodos , Simulação por Computador , Imagens de Fantasmas , Doses de Radiação , Espalhamento de Radiação
2.
NMR Biomed ; 18(5): 277-84, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15948233

RESUMO

Changes in the magnetic resonance (MR) parameters of demyelinated neural tissue were measured in vitro using an experimental animal model. A tellurium (Te) diet was applied to weanling rats to induce the demyelination process in the sciatic nerve. The quantitative MR parameters, such as T(1), T(2) relaxation time constants and magnetization transfer (MT) were measured each day after applying the Te diet (up to 7 days) and were found to be substantially different from those of normal nerves. An increase in the average T(1) and T(2) was observed along with a decrease in the MT ratio (MTR) and the quantitative MT parameter M(0B), which describes the semisolid pool of protons. Most of the MR parameters correlated very well with the myelin fraction of neural tissue evaluated by quantitative histopathology. The T(2) relaxation spectrum provided the most efficient quantitative assessment of changes in neural tissue microstructure and its analysis resulted in a powerful tool to distinguish the processes of demyelination and inflammation. In comparison, the MT measurements were less successful.


Assuntos
Doenças Desmielinizantes/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Nervo Isquiático/patologia , Neuropatia Ciática/patologia , Animais , Doenças Desmielinizantes/induzido quimicamente , Modelos Animais de Doenças , Técnicas In Vitro , Ratos , Ratos Endogâmicos Lew , Reprodutibilidade dos Testes , Nervo Isquiático/efeitos dos fármacos , Neuropatia Ciática/induzido quimicamente , Sensibilidade e Especificidade , Telúrio
3.
J Peripher Nerv Syst ; 10(1): 38-46, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15703017

RESUMO

Ingestion of tellurium (Te), a toxic element, produces paralysis of the hind limbs in weanling rats that is due to temporary, segmental demyelination of the sciatic nerves bilaterally. Weanling rats were fed a 1.1% elemental Te diet and sacrificed at various time points for histological and magnetic resonance (MR) analysis of the sciatic nerves. No controls exhibited impairments of the hind limbs, whereas Te-treated animals became progressively impaired with increased Te exposure. Toluidine blue-stained nerve sections of Te-treated animals showed widened endoneurial spaces, disrupted myelin sheaths, swollen Schwann cells, and a few instances of axonal degeneration. Te decreased healthy myelin by 68% and increased percent extracellular matrix by 45% on day 7. MR experiments showed a decrease in the area of the short T2 component, an increase in average T1, and an increase in the position of the intermediate T2 component in Te-treated nerves. The correlation coefficient for healthy myelin and average T1 was 0.88 and that for healthy myelin and the area underneath the short T2 component was 0.77. The area of the short T2 component has been postulated as the best measure of the process of demyelination.


Assuntos
Doenças Desmielinizantes/diagnóstico por imagem , Doenças do Sistema Nervoso Periférico/diagnóstico por imagem , Doenças do Sistema Nervoso Periférico/patologia , Nervo Isquiático/patologia , Telúrio/toxicidade , Animais , Doenças Desmielinizantes/induzido quimicamente , Doenças Desmielinizantes/patologia , Modelos Animais de Doenças , Imageamento por Ressonância Magnética , Doenças do Sistema Nervoso Periférico/induzido quimicamente , Radiografia , Ratos , Ratos Endogâmicos Lew , Nervo Isquiático/diagnóstico por imagem , Nervo Isquiático/efeitos dos fármacos