1.
Ann Biol Clin (Paris) ; 82(2): 225-236, 2024 06 05.
Artigo em Francês | MEDLINE | ID: mdl-38702892

RESUMO

Although two clusters have been identified in France, constitutional factor XI deficiency is a rare disorder. Acquired factor XI deficiency is extremely rare. The management of factor XI deficiency is not staightforward because of the unpredictable bleeding tendency that does not clearly relate to the factor XI level. Other haemostastis parameters have to be taken into account to evaluate the bleeding tendency. We report the cases of a congenital factor XI deficiency, an acquired factor XI deficiency and a von Willebrand disease associated to a factor XI deficiency. On the other hand, some interferences can lead to underestimation of factor XI and we report the case of an interference by lupus anticoagulant. The objective of this review is to better understand how to manage a reduced factor XI level.


Assuntos
Deficiência do Fator XI , Humanos , Deficiência do Fator XI/diagnóstico , Deficiência do Fator XI/complicações , Deficiência do Fator XI/sangue , Feminino , Masculino , Fator XI/análise , Doenças de von Willebrand/diagnóstico , Doenças de von Willebrand/complicações , França/epidemiologia , Pessoa de Meia-Idade , Adulto
2.
Crit Care Med ; 45(7): e715-e717, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28410347

RESUMO

OBJECTIVES: To compare accuracy of a continuous noninvasive cutaneous temperature using zero-heat-flux method to esophageal temperature and arterial temperature. DESIGN: Prospective study. SETTING: ICU and NeuroICU, University Hospital. PATIENTS: Fifty-two ICU patients over a 4-month period who required continuous temperature monitoring were included in the study, after informed consent. INTERVENTIONS: All patients had esophageal temperature probe and a noninvasive cutaneous device to monitor their core temperature continuously. In seven patients who required cardiac output monitoring, continuous iliac arterial temperature was collected. Simultaneous core temperatures were recorded from 1 to 5 days. Comparison to the esophageal temperature, considered as the reference in this study, used the Bland and Altman method with adjustment for multiple measurements per patient. MEASUREMENTS AND MAIN RESULTS: The esophageal temperature ranged from 33°C to 39.7°C, 61,298 pairs of temperature using zero-heat-flux and esophageal temperature were collected and 1,850 triple of temperature using zero-heat-flux, esophageal temperature, and arterial temperature. Bias and limits of agreement for temperature using zero-heat-flux were 0.19°C ± 0.53°C compared with esophageal temperature with an absolute difference of temperature pairs equal to or lower than 0.5°C of 92.6% (95% CI, 91.9-93.4%) of cases and equal to or lower than 1°C for 99.9% (95% CI, 99.7-100.0%) of cases. Compared with arterial temperature, bias and limits of agreement were -0.00°C ± 0.36°C with an absolute difference of temperature pairs equal to or lower than 0.5°C of 99.8% (95% CI, 95.3-100%) of cases. All absolute difference of temperature pairs between temperature using zero-heat-flux and arterial temperature and between arterial temperature and esophageal temperature were equal to or lower than 1°C. No local or systemic serious complication was observed. CONCLUSIONS: These results suggest a comparable reliability of the cutaneous sensor using the zero-heat-flux method compared with esophageal or iliac arterial temperatures measurements.


Assuntos
Temperatura Corporal/fisiologia , Unidades de Terapia Intensiva , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Termômetros , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Temperatura Cutânea/fisiologia