Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 67(5): 736-40, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19246204

RESUMO

A low-level gamma-ray spectrometry system, based on an HPGe-detector with 92% relative efficiency recently installed in the underground laboratory Felsenkeller at 110 m water equivalent (w.e.) depth, is described. The integral background count rate normalised to the Ge-crystal mass in the energy range from 40 keV until 2.7 MeV of 0.034 s(-1)kg(-1) has been achieved by careful material selection of the detector construction material, a graded shielding construction and effective radon suppression. The detector is highly suitable for the effective surveillance of water for human consumption with decision thresholds for (226)Ra and (228)Ra in the order of some mBq L(-1).


Assuntos
Radônio/análise , Espectrometria gama/instrumentação , Poluentes Radioativos da Água/análise , Humanos , Laboratórios , Espectrometria gama/métodos , Água/análise
2.
J Synchrotron Radiat ; 13(Pt 4): 314-20, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16799222

RESUMO

A Ge pixel array detector with 100 segments was applied to fluorescence X-ray absorption spectroscopy, probing the local structure of high-temperature superconducting thin-film single crystals (100 nm in thickness). Independent monitoring of pixel signals allows real-time inspection of artifacts owing to substrate diffractions. By optimizing the grazing-incidence angle theta and adjusting the azimuthal angle phi, smooth extended X-ray absorption fine structure (EXAFS) oscillations were obtained for strained (La,Sr)2CuO4 thin-film single crystals grown by molecular beam epitaxy. The results of EXAFS data analysis show that the local structure (CuO6 octahedron) in (La,Sr)2CuO4 thin films grown on LaSrAlO4 and SrTiO3 substrates is uniaxially distorted changing the tetragonality by approximately 5 x 10(-3) in accordance with the crystallographic lattice mismatch. It is demonstrated that the local structure of thin-film single crystals can be probed with high accuracy at low temperature without interference from substrates.


Assuntos
Algoritmos , Cristalografia/métodos , Germânio/efeitos da radiação , Cristais Líquidos/análise , Cristais Líquidos/química , Membranas Artificiais , Processamento de Sinais Assistido por Computador/instrumentação , Espectrometria por Raios X/instrumentação , Espectrometria por Raios X/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Conformação Molecular , Temperatura , Raios X
3.
J Synchrotron Radiat ; 12(Pt 1): 57-69, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15616366

RESUMO

This paper accounts for selected detector developments carried out over the past 15 years within the ESRF X-ray Absorption Spectroscopy group. This includes various types of photodiodes used as integrated current detectors. Special emphasis is put on the long-standing development of a Si drift-diode array suitable for energy-dispersive detection of X-ray fluorescence. This detector, which is now operational, was used to record high-quality XMCD/XAFS spectra on [Fe70Pt30] nanoparticles highly dispersed on a Si wafer. Using numerically deconvoluted spectra, energy resolution was decreased to 82 eV for the Si Kalphabeta line, 126 eV for the Fe Kalpha line and 176 eV for the Pt Lalpha line. A high-vacuum-compatible high-energy-resolution crystal analyzer was also installed on ID12, making it possible to record X-ray fluorescence excitation spectra in the photon-in/photon-out mode over a wide spectral range. Prospects of adapting these methods in order to investigate biological samples are briefly discussed.


Assuntos
Espectrometria de Fluorescência/instrumentação , Análise Espectral/instrumentação , Desenho de Equipamento , Fótons , Raios X
4.
J Synchrotron Radiat ; 5(Pt 3): 863-5, 1998 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-15263678

RESUMO

The performance of silicon-drift-detector (SDD) arrays and digital electronics designed for X-ray absorption spectroscopy in the fluorescence excitation mode is reported. Different detectors have been manufactured and tested: two single-channel SDDs with different active areas (10 mm(2) and 1 cm(2)) and a monolithic 2 cm(2) SDD with eight readout anodes. The energy resolution varies between 160 and 170 eV FWHM. A new digital multichannel shaping amplifier has been produced. Its performance is presented in comparison with that of a standard commercial shaper.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...