Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiol Case Rep ; 12(1): 31-33, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28228873

RESUMO

Brachytherapy consists of placing radioactive sources into or adjacent to tumors, to deliver conformal radiation treatment. The technique is used for treatment of primary malignancies and for salvage in recurrent disease. Permanent prostate brachytherapy seeds are small metal implants containing radioactive sources of I-125, Pd-103, or Cs-131 encased in a titanium shell. They can embolize through the venous system to the lungs or heart and subsequently be detected by cardiovascular computed tomography. Cardiovascular imagers should be aware of the appearance of migrated seeds, as their presence in the chest is generally benign, so that unnecessary worry and testing are avoided. We report a case of a patient who underwent brachytherapy for prostate cancer and developed a therapeutic seeds embolus to the right ventricle.

2.
Clin Imaging ; 40(4): 647-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27317209

RESUMO

A case of a tornado victim with a delayed presentation of injury to the aortic isthmus is discussed. Tornado forces resemble the forces of high energy explosions, and the injuries that can occur as a result of these forces can be bizarre. The patient presented with the unique computed tomography (CT) findings of isolated pseudoaneurysm of the thoracic aorta in the absence of other traumatic injury to the thorax. Equivocal results of the initial CT aortogram (CTA) were confirmed with ECG-synchronized CTA (ECG-CTA), demonstrating the superiority of ECG-CTA as compared to standard CTA.


Assuntos
Falso Aneurisma/diagnóstico por imagem , Aorta Torácica/diagnóstico por imagem , Aneurisma Aórtico/diagnóstico por imagem , Aortografia/métodos , Eletrocardiografia/métodos , Tomografia Computadorizada por Raios X/métodos , Tornados , Humanos , Masculino
3.
Int J Angiol ; 24(1): 71-4, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25780332

RESUMO

Appropriate placement of an inferior vena cava (IVC) filter necessitates imaging of the renal veins because when an IVC filter is deployed its tip should be at or below the inferior aspect of the inferiormost renal vein. Traditionally, imaging during placement of IVC filters has been with conventional cavography and fluoroscopy. Recently, intravascular ultrasound has been used for the same purpose but with additional expense. Morbidly obese patients often exceed the weight limit of fluoroscopy tables. In addition, short obese patients are at risk of falling from narrow fluoroscopy tables. For such patients, computed tomography (CT) guidance is a viable alternative to conventional fluoroscopic guidance. IVC placement was performed in the CT suite for two obese patients who exceeded the weight limits of the available fluoroscopy tables. In one case, a Vena-Tech filter (Braun Medical, Melsungen, Germany) was placed using CT fluoroscopy. In the second case, a Recovery (Bard, Murray Hill, NJ) filter was placed using intermittent limited z-axis scanning. In the first case, the filter was placed below the level of the renal veins and above the confluence of the iliac veins, which is acceptable placement. In the second case, with refinement of technique, the filter tip was placed less than 1 cm below the inferiormost renal vein, which is considered optimal placement. CT of the IVC precisely images the renal veins and can characterize their number and their confluence with the IVC. CT guidance is a viable alternative to fluoroscopic guidance for the placement of IVC filters in morbidly obese patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...