Acta Cir Bras ; 29(2): 132-44, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24604318

RESUMO

PURPOSE: To propose a simulation-based ultrasound-guided central venous cannulation skills' training program, during residency. METHODS: This study describes the strategies for learning the ultrasound-guided central venous cannulation on low-fidelity bench models. The preparation of bench models, educational goals, processes of skill acquisition, feedback and evaluation methods were also outlined. The training program was based on key references to the subject. RESULTS: It was formulated a simulation-based ultrasound-guided central venous cannulation teaching program on low-fidelity bench models. CONCLUSION: A simulation-based inexpensive, low-stress, no-risk learning program on low-fidelity bench models was proposed to facilitate acquisition of ultrasound-guided central venous cannulation skills by residents-in-training before exposure to the living patient.


Assuntos
Cateterismo Venoso Central/métodos , Internato e Residência/métodos , Ultrassonografia de Intervenção/métodos , Competência Clínica , Avaliação Educacional , Humanos , Ilustração Médica , Avaliação de Programas e Projetos de Saúde , Reprodutibilidade dos Testes , Materiais de Ensino , Fatores de Tempo , Ultrassonografia de Intervenção/instrumentação
2.
Acta cir. bras ; Acta cir. bras;29(2): 132-144, 02/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-702528

RESUMO

To propose a simulation-based ultrasound-guided central venous cannulation skills' training program, during residency. METHODS: This study describes the strategies for learning the ultrasound-guided central venous cannulation on low-fidelity bench models. The preparation of bench models, educational goals, processes of skill acquisition, feedback and evaluation methods were also outlined. The training program was based on key references to the subject. RESULTS: It was formulated a simulation-based ultrasound-guided central venous cannulation teaching program on low-fidelity bench models. CONCLUSION: A simulation-based inexpensive, low-stress, no-risk learning program on low-fidelity bench models was proposed to facilitate acquisition of ultrasound-guided central venous cannulation skills by residents-in-training before exposure to the living patient.


Assuntos
Animais , Cirurgia Geral/métodos , Educação , Ultrassom/métodos , Métodos de Estudo da Matéria Médica
3.
Acta cir. bras. ; 29(2): 132-144, 02/2014. tab, graf
Artigo em Inglês | VETINDEX | ID: vti-10203

RESUMO

To propose a simulation-based ultrasound-guided central venous cannulation skills' training program, during residency. METHODS: This study describes the strategies for learning the ultrasound-guided central venous cannulation on low-fidelity bench models. The preparation of bench models, educational goals, processes of skill acquisition, feedback and evaluation methods were also outlined. The training program was based on key references to the subject. RESULTS: It was formulated a simulation-based ultrasound-guided central venous cannulation teaching program on low-fidelity bench models. CONCLUSION: A simulation-based inexpensive, low-stress, no-risk learning program on low-fidelity bench models was proposed to facilitate acquisition of ultrasound-guided central venous cannulation skills by residents-in-training before exposure to the living patient.(AU)


Assuntos
Animais , Educação , Cirurgia Geral/métodos , Ultrassom/métodos , Métodos de Estudo da Matéria Médica