Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Opt Express ; 3(7): 1609-19, 2012 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-22808432

RESUMO

This paper demonstrates spatially selective sampling of the plasma membrane by the implementation of time-multiplexed holographic optical tweezers for Smart Droplet Microtools (SDMs). High speed (>1000fps) dynamical hologram generation was computed on the graphics processing unit of a standard display card and controlled by a user friendly LabView interface. Time multiplexed binary holograms were displayed in real time and mirrored to a ferroelectric Spatial Light Modulator. SDMs were manufactured with both liquid cores (as previously described) and solid cores, which confer significant advantages in terms of stability, polydispersity and ease of use. These were coated with a number of detergents, the most successful based upon lipids doped with transfection reagents. In order to validate these, trapped SDMs were maneuvered up to the plasma membrane of giant vesicles containing Nile Red and human biliary epithelial (BE) colon cancer cells with green fluorescent labeled protein (GFP)-labeled CAAX (a motif belonging to the Ras protein). Bright field and fluorescence images showed that successful trapping and manipulation of multiple SDMs in x, y, z was achieved with success rates of 30-50% and that subsequent membrane-SDM interactions led to the uptake of Nile Red or GFP-CAAX into the SDM.

2.
Opt Express ; 15(20): 12548-61, 2007 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-19550524

RESUMO

We report a multifocal multiphoton time-correlated single photon counting (TCSPC) fluorescence lifetime imaging (FLIM) microscope system that uses a 16 channel multi-anode PMT detector. Multiphoton excitation minimizes out-of-focus photobleaching, multifocal excitation reduces non-linear in-plane photobleaching effects and TCSPC electronics provide photon-efficient detection of the fluorescence decay profile. TCSPC detection is less prone to bleaching- and movement-induced artefacts compared to wide-field time-gated or frequency-domain FLIM. This microscope is therefore capable of acquiring 3-D FLIM images at significantly increased speeds compared to single beam multiphoton microscopy and we demonstrate this with live cells expressing a GFP tagged protein. We also apply this system to time-lapse FLIM of NAD(P)H autofluorescence in single live cells and report measurements on the change in the fluorescence decay profile following the application of a known metabolic inhibitor.

3.
Opt Express ; 15(24): 15656-73, 2007 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-19550853

RESUMO

We present a time domain optically sectioned fluorescence lifetime imaging (FLIM) microscope developed for high-speed live cell imaging. This single photon excited system combines wide field parallel pixel detection with confocal sectioning utilizing spinning Nipkow disc microscopy. It can acquire fluorescence lifetime images of live cells at up to 10 frames per second (fps), permitting high-speed FLIM of cell dynamics and protein interactions with potential for high throughput cell imaging and screening applications. We demonstrate the application of this FLIM microscope to real-time monitoring of changes in lipid order in cell membranes following cholesterol depletion using cyclodextrin and to the activation of the small GTP-ase Ras in live cells using FRET.

5.
J Microsc ; 217(Pt 1): 36-43, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15655060

RESUMO

Fluorescence imaging of green fluorescent protein (GFP) may be used to locate proteins in live cells and fluorescence lifetime imaging (FLIM) may be employed to probe the local microenvironment of proteins. Here we apply FLIM to GFP-tagged proteins at the cell surface and at an inhibitory natural killer (NK) cell immunological synapse (IS). We present a novel quantitative analysis of fluorescence lifetime images that we believe is useful to determine whether apparent FLIM heterogeneity is statistically significant. We observe that, although the variation of observed fluorescence lifetime of GFP-tagged proteins at the cell surface is close to the expected statistical range, the lifetime of GFP-tagged proteins in cells is shorter than recombinant GFP in solution. Furthermore the lifetime of GFP-tagged major histocompatibility complex class I protein is shortened at the inhibitory NK cell IS compared with the unconjugated membrane. Following our previous work demonstrating the ability of FLIM to report the local refractive index of GFP in solution, we speculate that these lifetime variations may indicate local refractive index changes. This application of our method for detecting small but significant differences in fluorescence lifetimes shows how FLIM could be broadly useful in imaging discrete membrane environments for a given protein.


Assuntos
Proteínas de Fluorescência Verde/metabolismo , Antígenos de Histocompatibilidade Classe I/metabolismo , Processamento de Imagem Assistida por Computador/métodos , Microscopia de Fluorescência/métodos , Linhagem Celular Transformada , Linhagem Celular Tumoral , Membrana Celular/imunologia , Membrana Celular/metabolismo , Antígenos de Histocompatibilidade Classe I/imunologia , Humanos , Células Matadoras Naturais/imunologia , Células Matadoras Naturais/metabolismo , Microscopia Confocal , Fótons , Receptores Imunológicos/imunologia , Receptores Imunológicos/metabolismo , Receptores KIR
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...