Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
R Soc Open Sci ; 10(5): 221557, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37234499

RESUMO

We have used a continuous-wave bi-static lidar system based on the Scheimpflug principle in measurements on flying insects above, and in the vicinity of, a small lake located in a forested area in Southern Sweden. The system, which operates on triangulation principles, has a high spatial resolution at close distance, followed by a subsequent decline in resolution further from the sensor, related to the compact system design with a separation of transmitter and receiver by only 0.81 m. Our study showed a strong increase in insect abundance especially at dusk, but also at dawn. Insect numbers decreased over water compared to over land, and larger insects were over-represented over water. Further, the average size of the insects increased at night compared to day time.

2.
Appl Spectrosc ; 76(2): 207-215, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34981992

RESUMO

Hydrogen chloride (HCl) monitoring during combustion/gasification of biomass fuels and municipal solid waste, such as polyvinyl chloride (PVC) and food residues, is demanded to avoid the adverse effect of HCl to furnace operation and to improve the quality of the gas products. Infrared tunable diode laser absorption spectroscopy (IR-TDLAS) is a feasible nonintrusive in-situ method for HCl measurements in harsh environments. In the present work, the measurement was performed using the R(3) line of the ν2 vibrational band of HCl at 5739.25 cm-1 (1742.4 nm). Water vapor is ubiquitous in combustion/gasification environments, and its spectral interference is one of the most common challenges for IR-TDLAS. Spectral analysis based on the current well-known databases was found to be insufficient to achieve an accurate measurement. The lack of accurate temperature-dependent water spectra can introduce thousands parts per million (ppm) HCl overestimation. For the first time, accurate spectroscopic data of temperature-dependent water spectra near 5739.3 cm-1 were obtained based on a systematic experimental investigation of the hot water lines in a well-controlled, hot flue gas with a temperature varying from 1100 to 1950 K. With the accurate knowledge of hot water interference, the HCl TDLAS system can achieve a detection limit of about 100 ppm⋅m at around 1500 K, and simultaneously the gas temperature can be derived. The technique was applied to measure the temporally resolved HCl release and local temperature over burning PVC particles in hot flue gas at 1790 K.

3.
Antibiotics (Basel) ; 10(6)2021 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-34201188

RESUMO

Hospital sewage constitutes an important point source for antibiotics and antibiotic-resistant bacteria due to the high antibiotic use. Antibiotic resistance can develop and cause problems in sewage systems within hospitals and municipal wastewater treatment plants, thus, interventions to treat hospital sewage on-site are important. Ozonation has proven effective in treating relatively clean wastewater, but the effect on untreated wastewater is unclear. Therefore, we piloted implementation of ozonation to treat wastewater in a tertiary hospital in Uppsala, Sweden. We measured active pharmaceutical ingredients (APIs) using liquid chromatography-mass spectrometry and antibiotic-resistant Enterobacteriaceae using selective culturing pre- and post-ozonation. Comparing low (1 m3/h) and high (2 m3/h) flow, we obtained a 'dose-dependent' effect of API reduction (significant reduction of 12/29 APIs using low and 2/29 APIs using high flow, and a mean reduction of antibiotics of 41% using low vs. 6% using high flow, 25% vs. 6% for all APIs). There was no significant difference in the amount of antibiotic-resistant Enterobacteiaceae pre- and post-ozonation. Our results demonstrate that ozonation of untreated wastewater can reduce API content. However, due to the moderate API decrease and numerous practical challenges in the on-site setting, this specific ozonation system is not suitable to implement at full scale in our hospital.

4.
Opt Express ; 29(5): 7232-7246, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33726229

RESUMO

Stray light is a known strong interference in spectroscopic measurements. Photons from high-intensity signals that are scattered inside the spectrometer, or photons that enter the detector through unintended ways, will be added to the spectrum as an interference signal. A general experimental solution to this problem is presented here by introducing a customized fiber for signal collection. The fiber-mount to the spectrometer consists of a periodically arranged fiber array that, combined with lock-in analysis of the data, is capable of suppressing stray light for improved spectroscopy. The method, which is referred to as fiber-based periodic shadowing, was applied to Raman spectroscopy in combustion. The fiber-based stray-light suppression method is implemented in an experimental setup with a high-power high-repetition-rate laser system used for Raman measurements in different room-temperature gas mixtures and a premixed flame. It is shown that the stray-light level is reduced by up to a factor of 80. Weak spectral lines can be distinguished, and therefore better molecular species identification, as well as concentration and temperature evaluation, were performed. The results show that the method is feasible and efficient in practical use and that it can be employed as a general tool for improving spectroscopic accuracy.

5.
Pediatr Res ; 89(4): 823-829, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32534453

RESUMO

BACKGROUND: Using an optical method based on tunable diode laser absorption spectroscopy, we previously assessed oxygen (O2) and water vapor (H2O) content in a tissue phantom of the preterm infant lung. Here we applied this method on newborn piglets with induced lung complications. METHODS: Five mechanically ventilated piglets were subjected to stepwise increased and decreased fraction of inspired oxygen (FiO2), to atelectasis using a balloon catheter in the right bronchus, and to pneumothorax by injecting air in the pleural cavity. Two diode lasers (764 nm for O2 gas absorption and 820 nm for H2O absorption) were combined in a probe delivering light either externally, on the skin, or internally, through the esophagus. The detector probe was placed dermally. RESULTS: Calculated O2 concentrations increased from 20% (IQR 17-23%) when ventilated with room air to 97% (88-108%) at FiO2 1.0. H2O was only detectable with the internal light source. Specific light absorption and transmission patterns were identified in response to atelectasis and pneumothorax, respectively. CONCLUSIONS: The optical method detected FiO2 variations and discriminated the two induced lung pathologies, providing a rationale for further development into a minimally invasive device for real-time monitoring gas changes in the lungs of sick newborn infants. IMPACT: Optical spectroscopy can detect pulmonary complications in an animal model. Oxygen concentrations can be evaluated in the lungs. Presents a novel minimally invasive method to detect lung oxygenation and complications. Potential to be developed into a lung monitoring method in newborn infants. Potential for bed-side detection of pulmonary complications in newborn infants.


Assuntos
Lasers , Oxigênio/metabolismo , Análise Espectral/métodos , Animais , Animais Recém-Nascidos , Gasometria , Esôfago , Fluoroscopia , Pulmão , Oxigênio/química , Imagens de Fantasmas , Respiração Artificial , Pele/patologia , Espectrofotometria , Suínos , Água
6.
Opt Express ; 27(12): 17348-17358, 2019 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-31252945

RESUMO

A molecular laser-radar system, based on the Scheimpflug principle, has been constructed and demonstrated for remote sensing of atmospheric CO2 concentrations using Differential Absorption Lidar (DIAL) in the (30012←00001) absorption band. The laser source is a Continues Wave (CW) Distributed-FeedBack (DFB) diode laser seeding an Erbium-doped fiber amplifier, emitting narrowband (3 MHz) tunable radiation with an output power of 1.3 W at 1.57 µm. The laser beam is expanded and transmitted to the atmosphere. The atmospheric backscattered signal is collected with a Newtonian telescope and detected with a linear InGaAs array detector satisfying the Scheimpflug condition. We present range-resolved measurements of atmospheric CO2 concentration from a test range of 2 km located in the city of Lund, Sweden. We discuss and provide scalable results for CO2 profiling with the Scheimpflug-lidar method.

7.
Opt Express ; 27(7): 10304-10310, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-31045174

RESUMO

We present an efficient fiber source designed for continuous-wave differential absorption light detection and ranging (CW DIAL) of atmospheric CO2-concentration. It has a linewidth of 3 MHz, a tuning range of 2 nm over the CO2 absorption peaks at 1.572 µm, and an output power of 1.3 W limited by available pump power. Results from the initial CW DIAL testing are also presented and discussed.

8.
J Biophotonics ; 12(8): e201800350, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30993871

RESUMO

Oxygen and water vapor content, in the lungs of a 3D-printed phantom model based on CT-images of a preterm infant, is evaluated using Tunable Diode Laser Absorption Spectroscopy (TDLAS) in Gas in Scattering Media Absorption Spectroscopy (GASMAS), that is, the TDLAS-GASMAS technique. Oxygen gas is detected through an absorption line near 764 nm and water vapor through an absorption line near 820 nm. A model with a lung containing interior structure is compared to a model with a hollow lung. Compared to the model with the hollow lung, both the mean absorption path length and the transmitted intensity are found to be lower for the model with the structured lung. A new approach, where laser light is delivered internally into the model through an optical fiber, is compared to dermal light administration, that is, illumination onto the skin, for the model with structure inside the lung. The internal light administration generally resulted in larger gas absorption, and higher signal-to-noise ratios, compared to the dermal light administration. The results from the phantom measurements show great promise for the internal illumination approach and a natural next step would be to investigate it further in clinical studies.


Assuntos
Absorção Fisico-Química , Luz , Pulmão/metabolismo , Pulmão/efeitos da radiação , Imagens de Fantasmas , Pele , Análise Espectral , Humanos , Fibras Ópticas , Oxigênio/metabolismo , Impressão Tridimensional
9.
J Biophotonics ; 11(11): e201800023, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29978572

RESUMO

Further improvements in the clinical care of our most vulnerable patients-preterm infants-are needed. Novel diagnostic and surveillance tools facilitate such advances. The GASMAS technique has shown potential to become a tool to, noninvasively, monitor gas in the lungs of preterm infants, by placing a laser source and a detector on the chest wall skin. It is believed that this technology will become a valuable clinical diagnostic tool for monitoring the lung function of these patients. Today, the technology is, for this application, in an early stage and further investigations are needed. In the present study, a three-dimensional computer model of the thorax of an infant is constructed, from a set of CT images. Light transport simulations are performed to provide information about the position dependence of the laser- and detector probe on the thorax of the infant. The result of the simulations, based on the study method and the specified model used in this work, indicates that measurement geometries in front and on the side of the lung are favorable in order to obtain a good gas absorption signal.


Assuntos
Simulação por Computador , Imageamento Tridimensional , Recém-Nascido Prematuro/metabolismo , Pulmão/diagnóstico por imagem , Pulmão/metabolismo , Oxigênio/metabolismo , Pele , Humanos , Lactente , Modelos Biológicos , Tomografia Computadorizada por Raios X
10.
J Biophotonics ; 11(3)2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28816029

RESUMO

There is a need to further improve the clinical care of our most vulnerable patients-preterm infants. Novel diagnostic and treatment tools facilitate such advances. Here, we evaluate a potential percutaneous optical monitoring tool to assess the oxygen and water vapor content in the lungs of preterm babies. The aim is to prepare for further clinical studies by gaining a detailed understanding of how the measured light intensity and gas absorption signal behave for different possible geometries of light delivery and receiver. Such an experimental evaluation is conducted for the first time utilizing a specially developed 3-dimensional-printed optical phantom based on a geometry model obtained from computer tomography images of the thorax (chest) of a 1700-g premature infant. The measurements yield reliable signals for source-detector distances up to about 50 mm, with stronger gas absorption signals at long separations and positions related to the lower part of the lung, consistent with a larger relative volume of this. The limitations of this study include the omission of scattering tissue within the lungs and that similar optical properties are used for the wavelengths employed for the 2 gases, yielding no indication on the optimal wavelength pair to use.


Assuntos
Recém-Nascido Prematuro/metabolismo , Lasers , Pulmão/diagnóstico por imagem , Oxigênio/metabolismo , Imagens de Fantasmas , Impressão Tridimensional , Tomografia Computadorizada por Raios X/instrumentação , Humanos , Recém-Nascido , Pulmão/metabolismo , Vapor
11.
Infect Ecol Epidemiol ; 8(1): 1553463, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30847040

RESUMO

Introduction: Negative environmental effects of active pharmaceutical ingredients (APIs) are increasingly recognized, especially concerning antibiotics, and hospitals are important point sources. "pCure" is a toilet rim block containing API-degrading enzymes; the producing company claims positive in vitro results but no implementation studies have been performed. Materials and methods: In a university hospital setting, 16 weeks were randomized to installation or no installation of pCure in all 261 toilets connected to the same cesspit where sewage water was sampled daily. Ninety-six samples were analyzed for 102 APIs using liquid chromatography/tandem mass spectrometry. Results and Discussion: Fifty-one APIs were detected with a large variation in levels but no significant differences in the initial statistical analysis. More statistical testing of API level ratios (pCure installed/not installed) yielded some cases of significant decrease. Differences were small and not consistent when comparing means and medians. We cannot exclude a small pCure effect but clearly pCure has no effect of biological importance. Conclusion: pCure is not useful to reduce drug residue discharge in a hospital setting. In a bigger perspective, our study exemplifies that products claiming to reduce an environmental problem need to be tested in on-site implementation studies by independent researchers before reaching the market.

12.
Rev Sci Instrum ; 88(5): 053111, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28571416

RESUMO

The use of diffuse, highly reflective optical components, in particular, a hemispherical BaSO4 diffuser, at the point of light injection into non-transparent or turbid media was evaluated as a means to increase the measurement sensitivity of spectroscopic absorption measurements. By performing the light injection from, e.g., an optical fiber through a component designed to make the light diffuse and to reflect (and thereby re-inject) light scattered from the sample, the total amount of light delivered into the sample is increased. Further, the occurrence of possible interference fringes is strongly reduced.

13.
Appl Opt ; 54(33): 9772-8, 2015 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-26836536

RESUMO

A highly scattering porous ceramic sample is employed as a miniature random-scattering multipass gas cell for monitoring of oxygen content in opaque media, that is, wood materials in the present work. Gas in scattering media absorption spectroscopy is used by employing a 760 nm near-infrared laser diode to probe the absorption of molecular oxygen enclosed in the pores of the ceramic material working as the multipass gas cell, with a porosity of 75%. A path length enhancement of approximately 26 times and a signal-to-noise ratio of about 60 were obtained for the ceramic sample used in this work. The gas sensor was then used in a case study of the gas diffusion in wood materials, namely, oak, spruce, and mahogany samples. Differences depending on whether gas diffusion was studied longitudinal or radial to the tree annual rings are demonstrated, with very little gas diffusing in the radial direction. We can also observe that the gas diffusion for the densest material-oak-had the fastest diffusion time, and mahogany, which had the lowest density, showed the slowest diffusion time.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...