Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Cancer Imaging ; 24(1): 90, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38982546

RESUMO

BACKGROUND: Exploring the value of baseline and early 18F-FDG PET/CT evaluations in prediction PFS in ER+/HER2- metastatic breast cancer patients treated with a cyclin-dependent kinase inhibitor in combination with an endocrine therapy. METHODS: Sixty-six consecutive breast cancer patients who underwent a pre-therapeutic 18F-FDG PET/CT and a second PET/CT within the first 6 months of treatment were retrospectively included. Metabolic tumour volume (MTV) and total lesion glycolysis (TLG) and Dmax, which represents tumour dissemination and is defined as the distance between the two most distant lesions, were computed. The variation in these parameters between baseline and early evaluation PET as well as therapeutic evaluation using PERCIST were assessed as prognosticators of PFS at 18 months. RESULTS: The median follow-up was equal to 22.5 months. Thirty progressions occurred (45.4%). The average time to event was 17.8 ± 10.4 months. At baseline, Dmax was the only predictive metabolic parameter. Patients with a baseline Dmax ≤ 18.10 cm had a significantly better 18 m-PFS survival than the others: 69.2% (7.7%) versus 36.7% (8.8%), p = 0.017. There was no association between PERCIST evaluation and 18 m-PFS status (p = 0.149) and there was no difference in 18 m-PFS status between patients classified as complete, partial metabolic responders or having stable metabolic disease. CONCLUSION: Disease spread at baseline PET, as assessed by Dmax, is predictive of an event occurring within 18 months. In the absence of early metabolic progression, which occurs in 15% of patients, treatment should be continued regardless of the quality of the initial response to treatment.


Assuntos
Neoplasias da Mama , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Humanos , Feminino , Neoplasias da Mama/patologia , Neoplasias da Mama/mortalidade , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/terapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Adulto , Intervalo Livre de Progressão , Inibidores de Proteínas Quinases/uso terapêutico , Quinases Ciclina-Dependentes/antagonistas & inibidores , Metástase Neoplásica , Prognóstico
2.
Artigo em Inglês | MEDLINE | ID: mdl-38900416

RESUMO

Importance: Whether F18-choline (FCH) positron emission tomographic (PET)/computed tomographic (CT) scan can replace Tc99m-sestaMIBI (MIBI) single-photon emission (SPE)CT/CT as a first-line imaging technique for preoperative localization of parathyroid adenomas (PTA) in patients with primary hyperparathyroidism (PHPT) is unclear. Objective: To compare first-line FCH PET/CT vs MIBI SPECT/CT for optimal care in patients with PHPT needing parathyroidectomy and to compare the proportions of patients in whom the first-line imaging method resulted in successful minimally invasive parathyroidectomy (MIP) and normalization of calcemia 1 month after surgery. Design, Setting, and Participants: A French multicenter randomized open diagnostic intervention phase 3 trial was conducted. Patients were enrolled from November 2019 to May 2022 and participated up to 6 months after surgery. The study included adults with PHPT and an indication for surgical treatment. Patients with previous parathyroid surgery or multiple endocrine neoplasia type 1 (MEN1) were ineligible. Interventions: Patients were assigned in a 1:1 ratio to receive first-line FCH PET/CT (FCH1) or MIBI SPECT/CT (MIBI1). In the event of negative or inconclusive first-line imaging, they received second-line FCH PET/CT (FCH2) after MIBI1 or MIBI SPECT/CT (MIBI2) after FCH1. All patients underwent surgery under general anesthesia within 12 weeks following the last imaging. Clinical and biologic (serum calcemia and parathyroid hormone levels) assessments were performed 1 and 6 months after surgery. Main Outcomes and Measures: The primary outcome was a true-positive first-line imaging-guided MIP combined with uncorrected serum calcium levels of 2.55 mmol/l or less 1 month after surgery, corresponding to the local upper limit of normality. Results: Overall, 57 patients received FCH1 (n = 29) or MIBI1 (n = 28). The mean (SD) age of patients was 62.8 (12.5) years with 15 male (26%) and 42 female (74%) patients. Baseline patient characteristics were similar between groups. Normocalcemia at 1 month after positive first-line imaging-guided MIP was observed in 23 of 27 patients (85%) in the FCH1 group and 14 of 25 patients (56%) in the MIBI1 group. Sensitivity was 82% (95% CI, 62%-93%) and 63% (95% CI, 42%-80%) for FCH1 and MIBI1, respectively. Follow-up at 6 months with biochemical measures was available in 43 patients, confirming that all patients with normocalcemia at 1 month after surgery still had it at 6 months. No adverse events related to imaging and 4 adverse events related to surgery were reported. Conclusions: This randomized clinical trial found that first-line FCH PET/CT is a suitable and safe replacement for MIBI SPECT/CT. FCH PET/CT leads more patients with PHPT to correct imaging-guided MIP and normocalcemia than MIBI SPECT/CT thanks to its superior sensitivity. Trial Registration: ClinicalTrials.gov Identifier: NCT04040946.

3.
EJNMMI Phys ; 10(1): 61, 2023 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-37804338

RESUMO

BACKGROUND: Small-animal PET imaging is an important tool in preclinical oncology. This study evaluated the ability of a clinical SiPM-PET camera to image several rats simultaneously and to perform quantification data analysis. METHODS: Intrinsic spatial resolution was measured using 18F line sources, and image quality was assessed using a NEMA NU 4-2018 phantom. Quantification was evaluated using a fillable micro-hollow sphere phantom containing 4 spheres of different sizes (ranging from 3.95 to 7.86 mm). Recovery coefficients were computed for the maximum (Amax) and the mean (A50) pixel values measured on a 50% isocontour drawn on each sphere. Measurements were performed first with the phantom placed in the centre of the field of view and then in the off-centre position with the presence of three scattering sources to simulate the acquisition of four animals simultaneously. Quantification accuracy was finally validated using four 3D-printed phantoms mimicking rats with four subcutaneous tumours each. All experiments were performed for both 18F and 68Ga radionuclides. RESULTS: Radial spatial resolutions measured using the PSF reconstruction algorithm were 1.80 mm and 1.78 mm for centred and off-centred acquisitions, respectively. Spill-overs in air and water and uniformity computed with the NEMA phantom centred in the FOV were 0.05, 0.1 and 5.55% for 18F and 0.08, 0.12 and 2.81% for 68Ga, respectively. Recovery coefficients calculated with the 18F-filled micro-hollow sphere phantom for each sphere varied from 0.51 to 1.43 for Amax and from 0.40 to 1.01 for A50. These values decreased from 0.28 to 0.92 for Amax and from 0.22 to 0.66 for A50 for 68 Ga acquisition. The results were not significantly different when imaging phantoms in the off-centre position with 3 scattering sources. Measurements performed with the four 3D-printed phantoms showed a good correlation between theoretical and measured activity in simulated tumours, with r2 values of 0.99 and 0.97 obtained for 18F and 68Ga, respectively. CONCLUSION: We found that the clinical SiPM-based PET system was close to that obtained with a dedicated small-animal PET device. This study showed the ability of such a system to image four rats simultaneously and to perform quantification analysis for radionuclides commonly used in oncology.

4.
Diagnostics (Basel) ; 13(9)2023 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-37175017

RESUMO

Given the constant pressure to increase patient throughput while respecting radiation protection, global body PET image quality (IQ) is not satisfactory in all patients. We first studied the association between IQ and other variables, in particular body habitus, on a digital PET/CT. Second, to improve and homogenize IQ, we evaluated a deep learning PET denoising solution (Subtle PETTM) using convolutional neural networks. We analysed retrospectively in 113 patients visual IQ (by a 5-point Likert score in two readers) and semi-quantitative IQ (by the coefficient of variation in the liver, CVliv) as well as lesion detection and quantification in native and denoised PET. In native PET, visual and semi-quantitative IQ were lower in patients with larger body habitus (p < 0.0001 for both) and in men vs. women (p ≤ 0.03 for CVliv). After PET denoising, visual IQ scores increased and became more homogeneous between patients (4.8 ± 0.3 in denoised vs. 3.6 ± 0.6 in native PET; p < 0.0001). CVliv were lower in denoised PET than in native PET, 6.9 ± 0.9% vs. 12.2 ± 1.6%; p < 0.0001. The slope calculated by linear regression of CVliv according to weight was significantly lower in denoised than in native PET (p = 0.0002), demonstrating more uniform CVliv. Lesion concordance rate between both PET series was 369/371 (99.5%), with two lesions exclusively detected in native PET. SUVmax and SUVpeak of up to the five most intense native PET lesions per patient were lower in denoised PET (p < 0.001), with an average relative bias of -7.7% and -2.8%, respectively. DL-based PET denoising by Subtle PETTM allowed [18F]FDG PET global image quality to be improved and homogenized, while maintaining satisfactory lesion detection and quantification. DL-based denoising may render body habitus adaptive PET protocols unnecessary, and pave the way for the improvement and homogenization of PET modalities.

5.
Front Med (Lausanne) ; 10: 1137514, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36993807

RESUMO

Introduction: The yield per elution of a 68Ge/68Ga generator decreases during its lifespan. This affects the number of patients injected per elution or the injected dose per patient, thereby negatively affecting the cost of examinations and the quality of PET images due to increased image noise. We aimed to investigate whether AI-based PET denoising can offset this decrease in image quality parameters. Methods: All patients addressed to our PET unit for a 68Ga-DOTATOC PET/CT from April 2020 to February 2021 were enrolled. Forty-four patients underwent their PET scans according to Protocol_FixedDose (150 MBq) and 32 according to Protocol_WeightDose (1.5 MBq/kg). Protocol_WeightDose examinations were processed using the Subtle PET software (Protocol_WeightDoseAI). Liver and vascular SUV mean were recorded as well as SUVmax, SUVmean and metabolic tumour volume (MTV) of the most intense tumoural lesion and its background SUVmean. Liver and vascular coefficients of variation (CV), tumour-to-background and tumour-to-liver ratios were calculated. Results: The mean injected dose of 2.1 (0.4) MBq/kg per patient was significantly higher in the Protocol_FixedDose group as compared to 1.5 (0.1) MBq/kg for the Protocol_WeightDose group. Protocol_WeightDose led to noisier images than Protocol_FixedDose with higher CVs for liver (15.57% ± 4.32 vs. 13.04% ± 3.51, p = 0.018) and blood-pool (28.67% ± 8.65 vs. 22.25% ± 10.37, p = 0.0003). Protocol_WeightDoseAI led to less noisy images than Protocol_WeightDose with lower liver CVs (11.42% ± 3.05 vs. 15.57% ± 4.32, p < 0.0001) and vascular CVs (16.62% ± 6.40 vs. 28.67% ± 8.65, p < 0.0001). Tumour-to-background and tumour-to-liver ratios were lower for protocol_WeightDoseAI: 6.78 ± 3.49 vs. 7.57 ± 4.73 (p = 0.01) and 5.96 ± 5.43 vs. 6.77 ± 6.19 (p < 0.0001), respectively. MTVs were higher after denoising whereas tumour SUVmax were lower: the mean% differences in MTV and SUVmax were + 11.14% (95% CI = 4.84-17.43) and -3.92% (95% CI = -6.25 to -1.59). Conclusion: The degradation of PET image quality due to a reduction in injected dose at the end of the 68Ge/68Ga generator lifespan can be effectively counterbalanced by using AI-based PET denoising.

6.
Diagnostics (Basel) ; 12(10)2022 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-36292136

RESUMO

This study aimed to investigate if combining clinical characteristics with pre-therapeutic 18 F-fluorodeoxyglucose (18 F-FDG) positron emission tomography (PET) radiomics could predict the presence of molecular alteration(s) in key molecular targets in lung adenocarcinoma. This non-interventional monocentric study included patients with newly diagnosed lung adenocarcinoma referred for baseline PET who had tumour molecular analyses. The data were randomly split into training and test datasets. LASSO regression with 100-fold cross-validation was performed, including sex, age, smoking history, AJCC cancer stage and 31 PET variables. In total, 109 patients were analysed, and it was found that 63 (57.8%) patients had at least one molecular alteration. Using the training dataset (n = 87), the model included 10 variables, namely age, sex, smoking history, AJCC stage, excessKustosis_HISTO, sphericity_SHAPE, variance_GLCM, correlation_GLCM, LZE_GLZLM, and GLNU_GLZLM. The ROC analysis for molecular alteration prediction using this model found an AUC equal to 0.866 (p < 0.0001). A cut-off value set to 0.48 led to a sensitivity of 90.6% and a positive likelihood ratio (LR+) value equal to 2.4. After application of this cut-off value in the unseen test dataset of patients (n = 22), the test presented a sensitivity equal to 90.0% and an LR+ value of 1.35. A clinico-metabolic 18 F-FDG PET phenotype allows the detection of key molecular target alterations with high sensitivity and negative predictive value. Hence, it opens the way to the selection of patients for molecular analysis.

7.
Mol Imaging Biol ; 24(6): 1018-1027, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35835951

RESUMO

PURPOSE: Single-photon emission computed tomography has found an important place in preclinical cancer research. Nevertheless, the cameras dedicated to small animals are not widely available. The present study aimed to assess the feasibility of imaging small animals by a newly released 360° cadmium zinc telluride camera (VERITON, Spectrum Dynamics, Israel) dedicated to human patients. PROCEDURES: A cylindrical phantom containing hot spheres was used to evaluate the intrinsic performance of the camera first without the presence of background activity and then with two contrasts between background and hot spheres (1/4 and 1/10). Acquisitions were repeated with different scan durations (10 and 20 min), two tested radioisotopes (Tc-99 m and I-123), and a set of reconstruction parameters (10 iterations [i] 8 subsets [s], 10i16s, 10i32s). A 3D-printed phantom mimicking a rat with four subcutaneous tumours was then used to test the camera under preclinical conditions. RESULTS: The results obtained from the micro-hollow sphere phantom showed that it was possible to visualize spheres with an inner diameter of 3.95 mm without background activity. Moreover, spheres with diameters of 4.95 mm can be seen in the condition of high contrast between background and spheres (1/10) and 7.86 mm with lower contrast (1/4). The rat-sized phantom acquisitions showed that 10- and 8-mm subcutaneous tumours were visible with a good contrast obtained for the two radioisotopes tested in this study. Both Tc-99 m and I-123 measurements demonstrated that a 10-min acquisition reconstructed with an ordered subset expectation maximization algorithm applying 10i32s was optimal to obtain sufficient image quality in terms of noise, resolution, and contrast. CONCLUSION: Phantom results showed the ability of the system to detect sub-centimetre lesions for various radioisotopes. It seemed feasible to image small animals using a 360° cadmium zinc telluride gamma camera for preclinical cancer research purposes.


Assuntos
Cádmio , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Animais , Ratos , Estudos de Viabilidade , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Imagens de Fantasmas , Zinco
8.
Eur J Nucl Med Mol Imaging ; 49(11): 3750-3760, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35593925

RESUMO

PURPOSE: We investigated whether artificial intelligence (AI)-based denoising halves PET acquisition time in digital PET/CT. METHODS: One hundred ninety-five patients referred for [18F]FDG PET/CT were prospectively included. Body PET acquisitions were performed in list mode. Original "PET90" (90 s/bed position) was compared to reconstructed ½-duration PET (45 s/bed position) with and without AI-denoising, "PET45AI and PET45". Denoising was performed by SubtlePET™ using deep convolutional neural networks. Visual global image quality (IQ) 3-point scores and lesion detectability were evaluated. Lesion maximal and peak standardized uptake values using lean body mass (SULmax and SULpeak), metabolic volumes (MV), and liver SULmean were measured, including both standard and EARL1 (European Association of Nuclear Medicine Research Ltd) compliant SUL. Lesion-to-liver SUL ratios (LLR) and liver coefficients of variation (CVliv) were calculated. RESULTS: PET45 showed mediocre IQ (scored poor in 8% and moderate in 68%) and lesion concordance rate with PET90 (88.7%). In PET45AI, IQ scores were similar to PET90 (P = 0.80), good in 92% and moderate in 8% for both. The lesion concordance rate between PET90 and PET45AI was 836/856 (97.7%), with 7 lesions (0.8%) only detected in PET90 and 13 (1.5%) exclusively in PET45AI. Lesion EARL1 SULpeak was not significantly different between both PET (P = 0.09). Lesion standard SULpeak, standard and EARL1 SULmax, LLR and CVliv were lower in PET45AI than in PET90 (P < 0.0001), while lesion MV and liver SULmean were higher (P < 0.0001). Good to excellent intraclass correlation coefficients (ICC) between PET90 and PET45AI were observed for lesion SUL and MV (ICC ≥ 0.97) and for liver SULmean (ICC ≥ 0.87). CONCLUSION: AI allows [18F]FDG PET duration in digital PET/CT to be halved, while restoring degraded ½-duration PET image quality. Future multicentric studies, including other PET radiopharmaceuticals, are warranted.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Inteligência Artificial , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos
9.
Semin Nucl Med ; 52(3): 286-301, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34823841

RESUMO

This article reviews the current evolution and future directions in PET/CT technology focusing on three areas: time of flight, image reconstruction, and data-driven gating. Image reconstruction is considered with advances in point spread function modelling, Bayesian penalised likelihood reconstruction, and artificial intelligence approaches. Data-driven gating is examined with reference to respiratory motion, cardiac motion, and head motion. For each of these technological advancements, theory will be briefly discussed, benefits of their use in routine practice will be detailed and potential future developments will be discussed. Representative clinical cases will be presented, demonstrating the huge opportunities given to the PET community by hardware and software advances in PET technology when it comes to lesion detection, disease characterization, accurate quantitation and quicker scans. Through this review, hospitals are encouraged to embrace, evaluate and appropriately implement the wide range of new PET technologies that are available now or in the near future, for the improvement of patient care.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Inteligência Artificial , Teorema de Bayes , Humanos , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos
10.
J Nucl Med ; 63(7): 995-1000, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34675110

RESUMO

Despite the feminization of the medical workforce, women do not have the same career perspectives as men. In nuclear medicine, little information is available on the sex gap regarding prominent author positions in scientific articles. Therefore, the purpose of this study was to evaluate recent trends in the sex distribution of first and last authorship of articles published in nuclear medicine journals. Methods: We conducted a bibliometric analysis of first and last author sex of articles published from 2014 to 2020 in 15 nuclear medicine journals. Manuscript title, article type, journal impact factor, date of publication, and first and last name and country of provenance of first and last authors were noted. The Gender API software was used to determine author sex. All statistics were descriptive. Results: Women represented 32.8% of first authors and 19.6% of last authors. Female authorship increased from 28.2% (428 of 1,518 articles) in 2014 to 35.5% (735 of 2,069 articles; relative increase, 72%) in 2020 (P < 0.001) for first authors and from 15.6% (237 of 1,518 articles) in 2014 to 20.5% (424 of 2,069 articles; relative increase, 79%) in 2020 (P < 0.001) for last authors. Parity was forecast for 2035 for first authors and 2052 for last authors. Female authorship increased in Europe for first authors (P = 0.014) and last authors (P < 0.001), in high-ranking journals for first authors (P = 0.004) and last authors (P < 0.001), and in other journal ranks for last authors (P = 0.01). Female first and last authorship rose for original articles (P = 0.02 and P = 0.01, respectively) and case reports (P < 0.001 and P = 0.002, respectively). Regarding collaborations, the proportion of articles produced by male first and last authors decreased from 62.2% in 2014 to 52.9% in 2020 in favor of female first and last authors (odds ratio, 1.07; P < 0.001), male first and female last authors (odds ratio, 1.05; P < 0.001), and female first and male last authors (odds ratio, 1.03; P < 0.001). Conclusion: Female first and last authorship in nuclear medicine journals increased substantially from 2014 to 2020, in particular in high-ranking journals, in Europe, and for original articles and case reports. Male-to-male collaborations decreased by 10% in favor of all other collaborations. Parity can be foreseen in a few decades.


Assuntos
Medicina Nuclear , Publicações Periódicas como Assunto , Autoria , Feminino , Humanos , Fator de Impacto de Revistas , Masculino , Editoração
11.
Sci Rep ; 11(1): 23812, 2021 12 10.
Artigo em Inglês | MEDLINE | ID: mdl-34893676

RESUMO

At present, 18F-fluorodesoxyglucose (18FDG) positron emission tomography (PET)/computed tomography (CT) cannot be used to omit a bone marrow biopsy (BMB) among initial staging procedures in follicular lymphoma (FL). The additional diagnostic value of skeletal textural features on baseline 18FDG-PET/CT in diffuse large B-cell lymphoma (DLBCL) patients has given promising results. The aim of this study is to evaluate the value of 18FDG-PET/CT radiomics for the diagnosis of bone marrow involvement (BMI) in FL patients. This retrospective bicentric study enrolled newly diagnosed FL patients addressed for baseline 18FDG PET/CT. For visual assessment, examinations were considered positive in cases of obvious bone focal uptakes. For textural analysis, the skeleton volumes of interest (VOIs) were automatically extracted from segmented CT images and analysed using LifeX software. BMB and visual assessment were taken as the gold standard: BMB -/PET - patients were considered as bone-NEGATIVE patients, whereas BMB +/PET -, BMB -/PET + and BMB +/PET + patients were considered bone-POSITIVE patients. A LASSO regression algorithm was used to select features of interest and to build a prediction model. Sixty-six consecutive patients were included: 36 bone-NEGATIVE (54.5%) and 30 bone-POSITIVE (45.5%). The LASSO regression found variance_GLCM, correlation_GLCM, joint entropy_GLCM and busyness_NGLDM to have nonzero regression coefficients. Based on ROC analysis, a cut-off equal to - 0.190 was found to be optimal for the diagnosis of BMI using PET pred.score. The corresponding sensitivity, specificity, PPV and NPV values were equal to 70.0%, 83.3%, 77.8% and 76.9%, respectively. When comparing the ROC AUCs with using BMB alone, visual PET assessment or PET pred.score, a significant difference was found between BMB versus visual PET assessments (p = 0.010) but not between BMB and PET pred.score assessments (p = 0.097). Skeleton texture analysis is worth exploring to improve the performance of 18FDG-PET/CT for the diagnosis of BMI at baseline in FL patients.


Assuntos
Osso e Ossos/diagnóstico por imagem , Fluordesoxiglucose F18 , Linfoma Folicular/diagnóstico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Idoso , Biomarcadores , Terapia Combinada , Feminino , Humanos , Linfoma Folicular/mortalidade , Linfoma Folicular/terapia , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons , Prognóstico , Curva ROC , Resultado do Tratamento
14.
Diagnostics (Basel) ; 11(7)2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34359281

RESUMO

AIM: To perform a comprehensive analysis of discordances between contrast-enhanced CT (ceCT) and 18F-FDG PET/CT in the evaluation of the extra-cerebral treatment monitoring in patients with stage IV melanoma. MATERIALS AND METHODS: We conducted a retrospective monocentric observational study over a 3-year period in patients referred for 18F-FDG PET/CT and ceCT in the framework of therapy monitoring of immune checkpoint (ICIs) as of January 2017. Imaging reports were analyzed by two physicians in consensus. The anatomical site responsible for discordances, as well as induced changes in treatment were noted. RESULTS: Eighty patients were included and 195 pairs of scans analyzed. Overall, discordances occurred in 65 cases (33%). Eighty percent of the discordances (52/65) were due to 18F-FDG PET/CT scans upstaging the patient. Amongst these discordances, 17/52 (33%) led to change in patient's management, the most frequent being radiotherapy of a progressing site. ceCT represented 13/65 (20%) of discordances and induced changes in patients' management in 2/13 cases (15%). The most frequent anatomical site involved was subcutaneous for 18F-FDG PET/CT findings and lung or liver for ceCT. CONCLUSIONS: Treatment monitoring with 18F-FDG PET/CT is more efficient than ceCT and has a greater impact in patient's management.

15.
Leuk Lymphoma ; 62(12): 2890-2898, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34219589

RESUMO

In DLBCL, the Deauville scoring system (DS) is the standard for PET/CT response assessment. An alternative system, based on the semi-quantitative change in standardized uptake values, namely ΔSUVmax, has been reported to be more objective than the DS. We aimed to compare ΔSUVmax and DS for risk stratification of DLBCL patients on end-of-treatment (EoT) PET. 108 consecutive patients were included. 2-year EFS Kaplan-Meier survival analyses and Cox regression models were performed. 2-year EFS was significantly different between favorable ΔSUVmax (favΔ < -86.5%) and unfavorable ΔSUVmax (unfavΔ ≥ -86.5%) patients: 100.0% ± 0.0 versus 58.3% ± 14.2 (p = 0.001). On Cox multivariable regression, ΔSUVmax status was the only independent predictor of 2-year EFS, outperforming DS. Therefore, ΔSUVmax should be computed for non-responder patients, especially DS4, as the 2-year EFS is not different between responders and non-responders in the case of favΔ. Further studies are needed in order to confirm this hypothesis.


Assuntos
Fluordesoxiglucose F18 , Linfoma Difuso de Grandes Células B , Humanos , Linfoma Difuso de Grandes Células B/diagnóstico por imagem , Linfoma Difuso de Grandes Células B/tratamento farmacológico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Prognóstico , Estudos Retrospectivos
17.
Ann Nucl Med ; 35(6): 669-679, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33770374

RESUMO

AIM: To evaluate the use of digital 18F-FDG PET/CT with small-voxels reconstruction for detecting in-transit metastases in melanoma patients with primary lesion located on the upper or lower limbs, in comparison with standard reconstruction and European Association of Nuclear Medicine Research limited (EARL)-compliant reconstruction mimicking former generation PET systems. METHODS: Forty-six PET examinations acquired in list mode on a Vereos digital PET/CT system were reconstructed with (1) the standard reconstruction [2 iterations, 10 subsets (2i10s), point-spread function (PSF) modelling and time-of-flight enabled, no post-filtering and voxel size of 2 mm], (2) a small-voxel reconstruction using 1 mm voxels otherwise using the same parameters, (3) an EARL-compliant reconstruction mimicking a former generation system. Comparison of results across these reconstructions was made for a blind randomized review using a 3-point scale for the presence of in-transit metastases and image quality as well as for tumour-to-background (T/B) ratios and noise level in reference organs. RESULTS: Seven of the thirty-two EARL-compliant images classified as negative moved to positive on 1mmPSF images, and 5 of the 6 EARL-compliant images classified as indeterminate moved to positive on 1mmPSF images (P = 0.01). Amongst a total of 20 PET examinations classified as positive using the 1mmPSF reconstruction, fifteen were considered true positive, five false positive results occurred. Twenty-four patients with 1 mm PSF images were classified as negative, none of those under active surveillance experienced in-transit metastases during the 17 months following their PET examination. The positive likelihood ratio for the 1 mm reconstruction was much higher than that observed for EARL-compliant images (14.7 vs 7.82). Importantly, negative likelihood ratios for the 1 mm and 1mmPSF reconstruction were almost perfect. Compared to EARL-compliant data, T/B ratios extracted from the 1mmPSF showed a 2.84-fold increase (P < 0.001). A similar pattern of statistically significant increase was observed for noise level in organs of reference. Image quality for the torso was found to be significantly lower for 1mmPSF reconstruction (P = 0.03). Image quality for the limbs was found to be better for 1mmPSF (P < 0.001). CONCLUSION: Digital PET with small-voxel reconstruction brings an additional value for the detection of in-transit metastases by reducing the number of indeterminate findings and making up for falsely negative scans using former generation PET systems. An acquisition encompassing lower or upper limbs as appropriate should be performed.


Assuntos
Fluordesoxiglucose F18 , Melanoma , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Masculino , Pessoa de Meia-Idade
18.
Radiology ; 300(1): E301-E307, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33724061

RESUMO

Background Early reports show the unequal effect the COVID-19 pandemic might have on men versus women engaged in medical research. Purpose To investigate whether the COVID-19 pandemic has had an impact on scientific publishing by female physicians in medical imaging. Materials and Methods The authors conducted a descriptive bibliometric analysis of the gender of the first and last authors of manuscripts submitted to the top 50 medical imaging journals from March to May 2020 (n = 2480) compared with the same period of the year in 2018 (n = 2238) and 2019 (n = 2355). Manuscript title, date of submission, first and last names of the first and last authors, journal impact factor, and author country of provenance were recorded. The Gender-API software was used to determine author gender. Statistical analysis comprised χ2 tests and multivariable logistic regression. Results Percentages of women listed as first and last authors were 31.6% (1172 of 3711 articles) and 19.3% (717 of 3711 articles), respectively, in 2018-2019 versus 32.3% (725 of 2248 articles) and 20.7% (465 of 2248 articles) in 2020 (P = .61 and P = .21, respectively). For COVID-19-related articles, 35.2% (89 of 253 articles) of first authors and 20.6% (52 of 253 articles) of last authors were women. No associations were found between first- and last-author gender, year of publication, and region of provenance. First and last authorship of high-ranking articles was not in favor of North American women whatever the year (odds ratio [OR], 0.79 [P = .05] and 0.72 [P = .02], respectively). Higher rates of female last authorship of high-ranking articles were observed in Europe (P = .003) and of female first authorship of low-ranking publications in Asia in 2020 (OR, 1.38; 95% CI: 0.98, 1.92; P = .06). Female first and last authorship of COVID-19-related articles was overrepresented for lowest-rank publications (P = .02 and P = .01, respectively). Conclusion One in three first authors and one in five last authors were women in 2018-2019 and 2020, respectively. Although the first 2020 lockdown did not diminish the quantity of women-authored publications, the impact on the quality was variable. ©RSNA, 2021 See also the editorial by Robbins and Khosa in this issue.


Assuntos
Autoria , Bibliometria , Pesquisa Biomédica/estatística & dados numéricos , COVID-19 , Publicações Periódicas como Assunto/estatística & dados numéricos , Sexismo/estatística & dados numéricos , Feminino , Humanos , Masculino , Pandemias , Quarentena , SARS-CoV-2
19.
EJNMMI Res ; 11(1): 11, 2021 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-33559764

RESUMO

PURPOSE: Until now, results evaluating the expression of PSMA in ovarian cancer were sparse and contradictory. The aim was to reinvestigate the feasibility of a PSMA targeted theranostic approach in epithelial ovarian cancers with data from the tumour bank of a referring cancer centre. MATERIALS AND METHODS: The OvaRessources Biological Resources Center database was screened from January 2004 to December 2017 to seek patients referred for the initial management of a serous epithelial ovarian cancer and for whom peritoneal histological samples were available in the tumour bank. Immunodetection of PSMA was performed to assess its cellular and neovascular expression. Slides were controlled by a certified pathologist, recorded as tiled tiff images and processed to compute the proportion of DAB stained surface. RESULTS: Of the 51 patients identified by the database screening, 32 patients were included resulting in 57 samples (32 pre-chemotherapy and 25 post-chemotherapy histological samples). Nine patients were chemo-sensitive, 10 were partially chemo-sensitive and 13 were chemo-resistant/refractory. In the entire dataset, the expression of PSMA was quasi-inexistent: %DABPSMA = 0.04 (± 0.12) %. There was no significant difference in the %DABPSMA of sensitive, partially sensitive and resistant/refractory patients. There was also no significant difference in %DABPSMA in tumours before and after chemotherapy in the 25 patients for whom both samples were available. CONCLUSION: The present work demonstrates that PSMA expression is negligible and a fortiori non-sufficient to ensure its usefulness as a prognosticator or a target for a theranostic strategy in ovarian cancers.

20.
BMC Endocr Disord ; 21(1): 3, 2021 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-33413316

RESUMO

BACKGROUND: The common endocrine disorder primary hyperparathyroidism (PHPT) can be cured by surgery. Preoperative localization of parathyroid adenoma (PTA) by imaging is a prerequisite for outpatient minimally invasive parathyroidectomy (MIP). Compared to inpatient bilateral cervical exploration (BCE) which is performed if imaging is inconclusive, MIP is superior in terms of cure and complication rates and less costly. The imaging procedure F18-choline (FCH) PET/CT outperforms Tc99m-sestaMIBI (MIBI) SPECT/CT for PTA localization, but it is much costlier. The aim of this study is to identify the most efficient first-line imaging modality for optimal patient care in PHPT without added cost to society. METHODS: We will conduct a multicenter open diagnostic intervention randomized phase III trial comparing two diagnostic strategies in patients with PHPT: upfront FCH PET/CT versus MIBI SPECT/CT. The primary endpoint is the proportion of patients in whom the first-line imaging method results in successful MIP and cure. Follow-up including biological tests will be performed 1 and 6 months after surgery. The main secondary endpoint is the social cost of both strategies. Other secondary endpoints are as follows: FCH PET/CT and MIBI SPECT/CT diagnostic performance, performance of surgical procedure and complication rate, FCH PET/CT inter- and intra-observer variability and optimization of FCH PET/CT procedure. Fifty-eight patients will be enrolled and randomized 1:1. DISCUSSION: FCH PET/CT is a highly efficient but expensive imaging test for preoperative PTA localization and costs three to four times more than MIBI SPECT/CT. Whether FCH PET/CT improves patient outcomes compared to the reference standard MIBI SPECT/CT is unknown. To justify its added cost, FCH PET/CT-guided parathyroid surgery should lead to improved patient management, resulting in higher cure rates and fewer BCEs and surgical complications. In the previous phase II APACH1 study, we showed that second-line FCH PET/CT led to a cure in 88% of patients with negative or inconclusive MIBI SPECT/CT. BCE could be avoided in 75% of patients and surgical complication rates were low. We therefore hypothesize that upfront FCH PET/CT would improve patient care in PHPT and that the reduction in clinical costs would offset the increase in imaging costs. TRIAL REGISTRATION: NCT04040946 , registered August 1, 2019.  Protocol version Version 2.1 dated from 2020/04/23.


Assuntos
Radioisótopos de Flúor/metabolismo , Hiperparatireoidismo Primário/cirurgia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Cirurgia Assistida por Computador/métodos , Tecnécio Tc 99m Sestamibi/metabolismo , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Ensaios Clínicos Fase III como Assunto , Feminino , Seguimentos , Humanos , Hiperparatireoidismo Primário/diagnóstico por imagem , Hiperparatireoidismo Primário/metabolismo , Hiperparatireoidismo Primário/patologia , Masculino , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Prognóstico , Compostos Radiofarmacêuticos/metabolismo , Ensaios Clínicos Controlados Aleatórios como Assunto , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...