Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Funct Biomater ; 13(4)2022 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-36412886

RESUMO

The continuous development of novel materials for biomedical applications is resulting in an increasingly better prognosis for patients. The application of more advanced materials relates to fewer complications and a desirable higher percentage of successful treatments. New, innovative materials being considered for biomedical applications are metallic alloys with an amorphous internal structure called metallic glasses. They are currently in a dynamic phase of development both in terms of formulating new chemical compositions and testing their properties in terms of intended biocompatibility. This review article intends to synthesize the latest research results in the field of biocompatible metallic glasses to create a more coherent picture of these materials. It summarizes and discusses the most recent findings in the areas of mechanical properties, corrosion resistance, in vitro cellular studies, antibacterial properties, and in vivo animal studies. Results are collected mainly for the most popular metallic glasses manufactured as thin films, coatings, and in bulk form. Considered materials include alloys based on zirconium and titanium, as well as new promising ones based on magnesium, tantalum, and palladium. From the properties of the examined metallic glasses, possible areas of application and further research directions to fill existing gaps are proposed.

2.
Materials (Basel) ; 14(14)2021 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-34300964

RESUMO

The paper presents a comparison of the results of the corrosion resistance for three Fe-B-Co-Si-based newly developed alloys with the addition of Nb and V. The corrosion performance differences and microstructure variations were systematically studied using scanning electron microscope, electric corrosion equipment, X-ray diffractometer, and differential calorimeter. It has been shown that each alloying addition increased the corrosion resistance. The highest corrosion resistance obtained by potentiodynamic polarization was found for the alloy with both Nb and V addons (Fe57Co10B20Si5Nb4V4) and lowest in the case of the basic four-element Fe62Co15B14Si9 material. This shows that the proper choice of additions is of significant influence on the final performance of the alloy and allows tailoring of the material for specific applications.

3.
Materials (Basel) ; 15(1)2021 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-35009398

RESUMO

Microstructure, mechanical properties, corrosion resistance, and biocompatibility were studied for rapidly cooled 3 mm rods of Zr40Ti15Cu10Ni10Be25, Zr50Ti5Cu10Ni10Be25, and Zr40Ti15Cu10Ni5Si5Be25 (at.%) alloys, as well as for the reference 316L stainless steel and Ti-based Ti6Al4V alloy. Microstructure investigations confirm that Zr-based bulk metallic samples exhibit a glassy structure with minor fractions of crystalline phases. The nanoindentation tests carried out for all investigated composite materials allowed us to determine the mechanical parameters of individual phases observed in the samples. The instrumental hardness and elastic to total deformation energy ratio for every single phase observed in the manufactured Zr-based materials are higher than for the reference materials (316L stainless steel and Ti6Al4V alloy). A scratch tester used to determine the wear behavior of manufactured samples and reference materials revealed the effect of microstructure on mechanical parameters such as residual depth, friction force, and coefficient of friction. Electrochemical investigations in simulated body fluid performed up to 120 h show better or comparable corrosion resistance of Zr-based bulk metallic glasses in comparison with 316L stainless steel and Ti6Al4V alloy. The fibroblasts viability studies confirm the good biocompatibility of the produced materials. All obtained results show that fabricated biocompatible Zr-based materials are promising candidates for biomedical implants that require enhanced mechanical properties.

4.
Materials (Basel) ; 13(24)2020 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-33348588

RESUMO

The paper presents studies of microstructure, magnetic and corrosion properties of the Gd58Ge20Si22, Gd56Ge20Si22Co2, Gd56Ge20Si22Ti2 and Gd56Ge20Si22Cr2 (at.%) alloys after isothermal heat treatment at 1450 K for 2 h. The structure investigations of the produced materials performed by X-ray diffraction show the presence of Gd5Ge2Si2-type phase in all investigated samples. DC and AC magnetic measurements confirmed that the Curie temperature depends on the chemical composition of the produced alloys. From M(T) characteristics, it was found that the lowest Curie point (TC = 268 K) was estimated for the Gd58Ge20Si22 sample, whereas the highest value of the Curie temperature (TC = 308 K) was for the Gd56Ge20Si22Cr2 alloys. Moreover, the GdGeSi alloy without alloying additions shows the highest magnetic entropy change |ΔSM| = 15.07 J⋅kg-1⋅K-1 for the maximum magnetic field of 2 T. The maximum |ΔSM| measured for the Gd56Ge20Si22 with the addition of Co, Ti or Cr for the same magnetic field was obtained in the vicinity of the Curie point and equals to 2.92, 2.73 and 2.95 J⋅kg-1⋅K-1, respectively. Electrochemical studies of the produced materials for 60 min and 55 days exposure in 3% NaCl solution show that the highest stability and corrosion resistance were exhibited the sample with added of Ti.

5.
Materials (Basel) ; 13(13)2020 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-32605283

RESUMO

The temperature dependence of magnetocrystalline anisotropy was investigated in detail for the polycrystalline Ni50Mn25Ga25, Ni50Mn25Ga20Ti5 and Ni50Mn25Ga20Gd5 ferromagnetic shape memory alloys in the temperature range of 50-400 K. The effective anisotropy constant was estimated from a series of high field magnetization curves based on the fitting procedure according to the law of approach to magnetic saturation. The low temperature martensitic phase was found to have a significantly higher anisotropy energy in comparison to a high temperature austenitic phase, which was observed through a sudden, distinct drop of anisotropy energy. The calculated values of the effective anisotropy constant were comparable to the results published by other authors. Moreover, the strong influence of chemical composition on the first-order phase transition and the second-order ferromagnetic to the paramagnetic transition was revealed. Finally, the strong coupling between the temperature dependence of the coercive field and the temperature dependence of magnetocrystalline anisotropy was also shown and discussed in the present study.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...