Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
1.
AAPS J ; 24(3): 66, 2022 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-35534647

RESUMO

Decades of discussion and publication have gone into the guidance from the scientific community and the regulatory agencies on the use and validation of pharmacokinetic and toxicokinetic assays by chromatographic and ligand binding assays for the measurement of drugs and metabolites. These assay validations are well described in the FDA Guidance on Bioanalytical Methods Validation (BMV, 2018). While the BMV included biomarker assay validation, the focus was on understanding the challenges posed in validating biomarker assays and the importance of having reliable biomarker assays when used for regulatory submissions, rather than definition of the appropriate experiments to be performed. Different from PK bioanalysis, analysis of biomarkers can be challenging due to the presence of target analyte(s) in the control matrices used for calibrator and quality control sample preparation, and greater difficulty in procuring appropriate reference standards representative of the endogenous molecule. Several papers have been published offering recommendations for biomarker assay validation. The situational nature of biomarker applications necessitates fit-for-purpose (FFP) assay validation. A unifying theme for FFP analysis is that method validation requirements be consistent with the proposed context of use (COU) for any given biomarker. This communication provides specific recommendations for biomarker assay validation (BAV) by LC-MS, for both small and large molecule biomarkers. The consensus recommendations include creation of a validation plan that contains definition of the COU of the assay, use of the PK assay validation elements that support the COU, and definition of assay validation elements adapted to fit biomarker assays and the acceptance criteria for both.


Assuntos
Bioensaio , Bioensaio/métodos , Biomarcadores/análise , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Padrões de Referência
2.
J Appl Lab Med ; 7(2): 596-606, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-34910147

RESUMO

The Global Lab Quality Initiative (GLQI), formerly known as the Emerging Countries program, was funded through a generous endowment from the Wallace H. Coulter Foundation. The aims of GLQI are to develop and implement innovative programs to promote education and training in laboratory medicine for low- or lower middle-income countries worldwide. From its inception in 2010, the GLQI was focused solely on the Latin America and Caribbean (LAC) region under the purview of AACC's Latin American Working Group (LAWG), the members of which have strong ties to the region thereby facilitating the partnerships with national societies. The LAWG has provided in-person workshops in the LAC countries, at the AACC Annual Scientific Meeting, and on-demand webinars. The LAWG aims to implement the GLQI aims in the LAC region. In-person workshops are based on best-practice recommendations and sources such as Clinical Laboratory Standard Institute guidelines and supplemented with professional experiences of the LAWG's lecturers and local experts of the countries visited. In 2015, the GLQI expanded to other regions of the world. Here we report the experience of the LAWG workshops, results of participant surveys, in-person visits to laboratories post-workshop, and the lessons learned throughout the years across different geographic areas. We are hopeful this report provides insights into the challenges and successes of the LAWG in LAC to help support the expansion of the GLQI.


Assuntos
Renda , Laboratórios , Região do Caribe , Humanos , América Latina , Universidades
3.
Clin Pharmacol Ther ; 109(6): 1575-1582, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33280089

RESUMO

Development of monoclonal antibodies (mAbs) targeting immune-checkpoint receptors (IMRs) for the treatment of cancer is one of the most active areas of investment in the biopharmaceutical industry. A key decision in the clinical development of anti-IMR mAbs is dose selection. Dose selection can be challenging because the traditional oncology paradigm of administering the maximum tolerated dose is not applicable to anti-IMR mAbs. Instead, dose selection should be informed by the pharmacology of immune signaling. Engaging an IMR is a key initial step to triggering pharmacologic effects, and turnover (i.e., the rate of protein synthesis) of the IMR is a key property to determining the dose level needed to engage the IMR. Here, we applied the stable isotope labeling mass spectrometry technique using 13 C6 -leucine to measure the in vivo turnover rates of IMRs in humans. The 13 C6 -leucine was administered to 10 study participants over 15 hours to measure 13 C6 -leucine enrichment kinetics in 2 IMR targets that have been clinically pursued in oncology: GITR and PD-1. We report the first measurements of GITR and PD-1 median half-lives associated with turnover to be 55.6 and ≥ 49.5 hours, respectively. The approach outlined here can be applied to other IMRs and, more generally, to protein targets.


Assuntos
Anticorpos Monoclonais/administração & dosagem , Anticorpos Monoclonais/uso terapêutico , Proteína Relacionada a TNFR Induzida por Glucocorticoide/metabolismo , Inibidores de Checkpoint Imunológico/uso terapêutico , Receptor de Morte Celular Programada 1/metabolismo , Algoritmos , Meia-Vida , Voluntários Saudáveis , Humanos , Imunoterapia , Leucina/farmacocinética , Espectrometria de Massas , Reprodutibilidade dos Testes
4.
Clin Transl Sci ; 13(5): 871-876, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32475012

RESUMO

In the last few months, an unprecedented number of laboratory tests for coronavirus disease 2019 (COVID-19) have been developed at a remarkable speed. With the rapid adoption of these tests into clinical practice, combined with the widespread publicity they received, questions arose related to the different types of tests, their utility, performance, and regulatory approval status. The aim of this publication is to provide a general landscape of laboratory testing for COVID-19 and offer a historical and regulatory perspective associated with them. Specifically, we aim to elaborate on the regulatory complexities of diagnostic testing in the United States and its implications to the present outbreak, as well as provide a synopsis of laboratory tests that have been developed for COVID-19. We will first address the detection of severe acute respiratory syndrome-coronavirus 2 directly by either nucleic acid amplification tests or by the detection of the viral protein for active infections. Subsequently, we will provide an overview of serological tests that can aid not only in diagnosis but additionally help to identify prior infections and potential immunity.


Assuntos
Betacoronavirus/isolamento & purificação , Serviços de Laboratório Clínico/organização & administração , Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/diagnóstico , Pneumonia Viral/diagnóstico , Testes Sorológicos/métodos , Anticorpos Antivirais/imunologia , Anticorpos Antivirais/isolamento & purificação , Antígenos Virais/imunologia , Antígenos Virais/isolamento & purificação , Betacoronavirus/genética , Betacoronavirus/imunologia , COVID-19 , Teste para COVID-19 , Serviços de Laboratório Clínico/legislação & jurisprudência , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/transmissão , Infecções por Coronavirus/virologia , Humanos , Pandemias , Pneumonia Viral/epidemiologia , Pneumonia Viral/transmissão , Pneumonia Viral/virologia , RNA Viral/isolamento & purificação , SARS-CoV-2 , Estados Unidos
5.
Clin Chem ; 66(2): 282-301, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32040572

RESUMO

Immunoaffinity-mass spectrometry (IA-MS) is an emerging analytical genre with several advantages for profiling and determination of protein biomarkers. Because IA-MS combines affinity capture, analogous to ligand binding assays (LBAs), with mass spectrometry (MS) detection, this platform is often described using the term hybrid methods. The purpose of this report is to provide an overview of the principles of IA-MS and to demonstrate, through application, the unique power and potential of this technology. By combining target immunoaffinity enrichment with the use of stable isotope-labeled internal standards and MS detection, IA-MS achieves high sensitivity while providing unparalleled specificity for the quantification of protein biomarkers in fluids and tissues. In recent years, significant uptake of IA-MS has occurred in the pharmaceutical industry, particularly in the early stages of clinical development, enabling biomarker measurement previously considered unattainable. By comparison, IA-MS adoption by CLIA laboratories has occurred more slowly. Current barriers to IA-MS use and opportunities for expanded adoption are discussed. The path forward involves identifying applications for which IA-MS is the best option compared with LBA or MS technologies alone. IA-MS will continue to benefit from advances in reagent generation, more sensitive and higher throughput MS technologies, and continued growth in use by the broader analytical community. Collectively, the pursuit of these opportunities will secure expanded long-term use of IA-MS for clinical applications.


Assuntos
Cromatografia Líquida/métodos , Imunoensaio/métodos , Espectrometria de Massas em Tandem/métodos , Bioensaio , Biomarcadores/análise , Humanos , Proteínas/análise , Sensibilidade e Especificidade
6.
J Appl Lab Med ; 5(1): 15-28, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31811079

RESUMO

BACKGROUND: Accurate diagnosis of Alzheimer disease (AD) involving less invasive molecular procedures and at reasonable cost is an unmet medical need. We identified a serum miRNA signature for AD that is less invasive than a measure in cerebrospinal fluid. METHODS: From the Oxford Project to Investigate Memory and Aging (OPTIMA) study, 96 serum samples were profiled by a multiplex (>500 analytes) microRNA (miRNA) reverse transcription quantitative PCR analysis, including 51 controls, 32 samples from patients with AD, and 13 samples from patients with mild cognitive impairment (MCI). Clinical diagnosis of a subset of AD and the controls was confirmed by postmortem (PM) histologic examination of brain tissue. In a machine learning approach, the AD and control samples were split 70:30 as the training and test cohorts. A multivariate random forest statistical analysis was applied to construct and test a miRNA signature for AD identification. In addition, the MCI participants were included in the test cohort to assess whether the signature can identify early AD patients. RESULTS: A 12-miRNA signature for AD identification was constructed in the training cohort, demonstrating 76.0% accuracy in the independent test cohort with 90.0% sensitivity and 66.7% specificity. The signature, however, was not able to identify MCI participants. With a subset of AD and control participants with PM-confirmed diagnosis status, a separate 12-miRNA signature was constructed. Although sample size was limited, the PM-confirmed signature demonstrated improved accuracy of 85.7%, largely owing to improved specificity of 80.0% with comparable sensitivity of 88.9%. CONCLUSION: Although additional and more diverse cohorts are needed for further clinical validation of the robustness, the miRNA signature appears to be a promising blood test to diagnose AD.


Assuntos
Doença de Alzheimer , Encéfalo , MicroRNA Circulante/sangue , Disfunção Cognitiva , Perfilação da Expressão Gênica/métodos , Aprendizado de Máquina , Idoso , Doença de Alzheimer/sangue , Doença de Alzheimer/diagnóstico , Doença de Alzheimer/genética , Doença de Alzheimer/mortalidade , Autopsia/métodos , Encéfalo/metabolismo , Encéfalo/patologia , Disfunção Cognitiva/líquido cefalorraquidiano , Disfunção Cognitiva/diagnóstico , Disfunção Cognitiva/genética , Diagnóstico Precoce , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Transcriptoma
7.
Clin Infect Dis ; 71(1): 81-86, 2020 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-31628838

RESUMO

BACKGROUND: Endogenous antibodies (eAbs) against Clostridioides (Clostridium) difficile toxins may protect against recurrence of C. difficile infection (rCDI). This hypothesis was tested using placebo group data from MODIFY (Monoclonal Antibodies for C. difficile Therapy) I and II (NCT01241552 and NCT01513239, respectively), global, randomized phase 3 trials that assessed the efficacy and safety of the antitoxin monoclonal antibodies bezlotoxumab and actoxumab in participants receiving antibiotic therapy for CDI. METHODS: A placebo infusion (normal saline) was administered on study day 1. Serum samples were collected on day 1, week 4, and week 12, and eAb-A and eAb-B titers were measured by 2 validated electrochemiluminescence immunoassays. Rates of initial clinical cure and rCDI were summarized by eAb titer category (low, medium, high) at each time point. RESULTS: Serum eAb titers were available from a total of 773 participants. The proportion of participants with high eAb-A and eAb-B titers increased over time. Rates of initial clinical cure were similar across eAb titer categories. There was no correlation between eAb-A titers and rCDI rate at any time point. However, there was a negative correlation between rCDI and eAb-B titer on day 1 and week 4. rCDI occurred in 22% of participants with high eAb-B titers at baseline compared with 35% with low or medium titers (P = .015). CONCLUSIONS: Higher eAb titers against toxin B, but not toxin A, were associated with protection against rCDI. These data are consistent with the observed efficacy of bezlotoxumab, and lack of efficacy of actoxumab, in the MODIFY trials. CLINICAL TRIALS REGISTRATION: NCT01241552 and NCT01513239.


Assuntos
Antitoxinas , Clostridioides difficile , Infecções por Clostridium , Anticorpos Neutralizantes , Antitoxinas/uso terapêutico , Clostridioides , Infecções por Clostridium/tratamento farmacológico , Humanos , Recidiva
8.
Sci Rep ; 9(1): 114, 2019 01 14.
Artigo em Inglês | MEDLINE | ID: mdl-30643180

RESUMO

Tumor tissue mutational burden (TMB) has emerged as a promising predictive biomarker for immune checkpoint therapy. Measuring TMB from circulating tumor DNA (ctDNA) found in plasma is attractive in tissue-constrained indications. We compared the performance of two plasma-based commercial TMB assays including the effect of two different collection methods. Our findings suggest that the two plasma based TMB assays are highly correlated and they are also both correlated with a tissue-based TMB assay for relatively high TMB samples. The two collection methods are also found to be very comparable. Plasma-based TMB assays may be mature enough to be clinically useful in mCRPC and potentially other indications.


Assuntos
Biomarcadores Tumorais/sangue , DNA Tumoral Circulante/sangue , Neoplasias de Próstata Resistentes à Castração/genética , Neoplasias de Próstata Resistentes à Castração/terapia , Carga Tumoral , Humanos , Imunoterapia , Biópsia Líquida , Masculino , Mutação , Neoplasias de Próstata Resistentes à Castração/sangue
9.
Bioanalysis ; 10(23): 1897-1917, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30488729

RESUMO

The 2018 12th Workshop on Recent Issues in Bioanalysis took place in Philadelphia, PA, USA on April 9-13, 2018 with an attendance of over 900 representatives from pharmaceutical/biopharmaceutical companies, biotechnology companies, contract research organizations and regulatory agencies worldwide. WRIB was once again a 5-day, week-long event - a full immersion week of bioanalysis, biomarkers and immunogenicity. As usual, it was specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest including both small- and large-molecule bioanalysis involving LCMS, hybrid LBA/LCMS and LBA/cell-based assays approaches. This 2018 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2018 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 2) covers the recommendations for PK, PD and ADA assays by hybrid LBA/LCMS and regulatory agencies' input. Part 1 (LCMS for small molecules, peptides, oligonucleotides and small molecule biomarkers) and Part 3 (LBA/cell-based assays: immunogenicity, biomarkers and PK assays) are published in volume 10 of Bioanalysis, issues 22 and 24 (2018), respectively.


Assuntos
Antígenos/análise , Bioensaio/normas , Biomarcadores/análise , Legislação Médica/tendências , Estados Unidos
10.
J Clin Pharmacol ; 58(2): 254-262, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28884824

RESUMO

Anacetrapib is a cholesteryl ester transfer protein (CETP) inhibitor being developed for the treatment of mixed dyslipidemia. The aim of the study was to evaluate the pharmacokinetic, pharmacodynamic, and safety characteristics of anacetrapib following single doses in healthy, young Japanese men. In a double-blind, randomized, placebo-controlled, 3-panel, single-rising-dose study, 6 healthy young Japanese male or white male subjects (aged 19 to 44 years) received single oral doses of 5 to 500 mg anacetrapib, and 2 received placebo. Plasma and urine drug concentrations were measured 0-168 hours postdose, and plasma CETP inhibition was measured 0-24 hours postdose. Urinary anacetrapib levels were all below quantitation limits. Plasma concentrations of anacetrapib increased approximately less than dose-proportionally. Consumption of a traditional Japanese breakfast prior to dosing increased the plasma pharmacokinetics of anacetrapib in Japanese subjects compared with fasted conditions, to a similar extent as in white subjects. CETP activity measured over 0-24 hours postdose resulted in significant inhibition. Anacetrapib was generally well tolerated, and there were no serious adverse experiences. No clinically meaningful differences in PK and CETP inhibition parameters were found between Japanese and white subjects.


Assuntos
Anticolesterolemiantes/farmacologia , Proteínas de Transferência de Ésteres de Colesterol/antagonistas & inibidores , Oxazolidinonas/farmacologia , Adulto , Anticolesterolemiantes/sangue , Povo Asiático , Proteínas de Transferência de Ésteres de Colesterol/sangue , Citocromo P-450 CYP3A/metabolismo , Método Duplo-Cego , Voluntários Saudáveis , Humanos , Masculino , Oxazolidinonas/sangue , População Branca , Adulto Jovem
11.
Bioanalysis ; 9(23): 1895-1912, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29205053

RESUMO

The 2017 11th Workshop on Recent Issues in Bioanalysis (11th WRIB) took place in Los Angeles/Universal City, California on 3-7 April 2017 with participation of close to 750 professionals from pharmaceutical/biopharmaceutical companies, biotechnology companies, contract research organizations and regulatory agencies worldwide. WRIB was once again a 5-day, weeklong event - a full immersion week of bioanalysis, biomarkers and immunogenicity. As usual, it was specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest including both small and large molecule analysis involving LCMS, hybrid ligand binding assay (LBA)/LCMS and LBA approaches. This 2017 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2017 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 2) covers the recommendations for biotherapeutics, biomarkers and immunogenicity assays using hybrid LBA/LCMS and regulatory agencies' inputs. Part 1 (LCMS for small molecules, peptides and small molecule biomarkers) and Part 3 (LBA: immunogenicity, biomarkers and pharmacokinetic assays) are published in Volume 9 of Bioanalysis, issues 22 and 24 (2017), respectively.


Assuntos
Biomarcadores/análise , Imunidade Ativa , Espectrometria de Massas , Cromatografia Líquida de Alta Pressão , Conferências de Consenso como Assunto , Regulamentação Governamental , Ligantes
12.
Alzheimers Dement (Amst) ; 6: 201-209, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28349119

RESUMO

INTRODUCTION: Changes in cerebrospinal fluid (CSF) tau and amyloid ß (Aß)42 accompany development of Alzheimer's brain pathology. Robust tau and Aß42 immunoassays were developed to establish a tau/Aß42 cutoff distinguishing mild-to-moderate Alzheimer's disease (AD) subjects from healthy elderly control (HC) subjects. METHODS: A CSF tau/Aß42 cutoff criteria was chosen, which distinguished the groups and maximized concordance with amyloid PET. Performance was assessed using an independent validation cohort. RESULTS: A tau/Aß42 = 0.215 cutoff provided 94.8% sensitivity and 77.7% specificity. Concordance with PET visual reads was estimated at 86.9% in a ∼50% PET positive population. In the validation cohort, the cutoff demonstrated 78.4% sensitivity and 84.9% specificity to distinguish the AD and HC populations. DISCUSSION: A tau/Aß42 cutoff with acceptable sensitivity and specificity distinguished HC from mild-to-moderate AD subjects and maximized concordance to brain amyloidosis. The defined cutoff demonstrated that CSF analysis may be useful as a surrogate to imaging assessment of AD pathology.

13.
Rapid Commun Mass Spectrom ; 31(2): 193-199, 2017 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-27794205

RESUMO

RATIONALE: In quantitative analysis of protein biomarkers and therapeutic proteins by liquid chromatography/mass spectrometry (LC/MS), it is a preferred and well-established approach to digest with proteolytic enzymes to produce smaller peptide fragments which are more suitable for LC/MS analysis than the intact protein. In-solution digestion is one widely used method for protein digestion. Proteolytically resistant proteins often require digestion times that extend beyond normal working hours and prohibit same day analysis. We evaluated the performance of an immobilized enzyme reactor (IMER) to determine if this technology could reduce method development time, digestion time and increase throughput. METHODS: We digested human plasma samples using a commercially available IMER, Flash Digest, and compared it to an in-solution digestion method for analysis of three different apolipoprotein biomarkers APOE, APOC2, and APOC3. The plasma digests were analyzed via LC/MS using electrospray ionization (ESI) and multiple reaction monitoring (MRM). Value assigned calibrators were selected over a relevant physiological concentration range for each protein of interest. Quality control samples (QCs) and 'unknown' human plasma samples were analyzed with both methods. RESULTS: Flash Digest significantly reduced digestion time for APOC3, the most proteolytically resistant of the three proteins, to 30 min compared with overnight used with in-solution digestion. The Flash Digest achieved comparable digestion efficiency with minimal method development and reduced sample preparation time. Both methods showed linearity over a physiologically relevant concentration range. Precision was evaluated and a percentage coefficient of variance (% CV) less than 8% was obtained during intra-day reproducibility evaluation for all three apolipoproteins with Flash Digest. Concentrations observed for QCs and unknown samples using Flash Digest were comparable to the in-solution method. CONCLUSIONS: An IMER such as Flash Digest may be a potential alternative to in-solution digestion to accelerate digestion of proteolytically resistant proteins in a quantitative proteomics experiments, reduce method development time and increase throughput. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Proteoma/análise , Proteoma/metabolismo , Proteômica/métodos , Biomarcadores , Detergentes , Enzimas Imobilizadas/metabolismo , Células Hep G2 , Humanos , Modelos Lineares , Fragmentos de Peptídeos/análise , Fragmentos de Peptídeos/química , Fragmentos de Peptídeos/metabolismo , Proteólise , Proteoma/química , Tripsina/metabolismo
14.
Bioanalysis ; 8(22): 2341-2349, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27712087

RESUMO

AIM: Patients with elevated levels of B-type natriuretic peptide (BNP) and/or NT-proBNP as measured by clinical tests have an elevated risk of heart failure (HF). Despite utility in large clinical studies, both assays are plagued by large biological variability and specificity issues. To address these concerns and further investigate BNP in the HF setting, we developed an LC/MS assay to characterize the ratio of active to total BNP. RESULTS: We have developed and validated a novel immunoaffinity LC/MS assay to measure BNP-derived fragments, as well as 'total BNP' in human plasma. The ratio of active BNP1-32 to total BNP in 11 HF subjects was found to be <8%, and the sum of detectable BNP fragments contributed approximately 20% of total BNP. CONCLUSION: We developed an assay with the specificity to measure the active form of BNP, which may aid in the accurate diagnosis and better management of HF.

15.
Bioanalysis ; 8(15): 1557-1564, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27397798

RESUMO

BACKGROUND: For quantitative immunoaffinity IA-LC-MS, the utility of antibodies has been demonstrated many times but the utility of aptamers as affinity reagents is unproven. METHODS: Immunoaffinity reagents including a monoclonal antibody and an aptamer were coupled to magnetic beads and used as part of an enrichment strategy for PCSK9 quantitation in plasma. RESULTS: With limited method development, we have established a comparison of an anti-PCSK9 aptamer with an anti-PCSK9 monoclonal antibody. The background that results from a tryptic digest of affinity enrichment in plasma was demonstrated for each reagent using high-resolution full scan MS. The assay recovery was demonstrated for multiple concentrations of aptamer in plasma with different concentrations of PCSK9 protein. CONCLUSION: The aptamer achieved comparable enrichment to the antibody, but with lower peptide background, thus demonstrating the potential use of aptamers for IA-LC-MS.


Assuntos
Aptâmeros de Nucleotídeos/química , Cromatografia de Afinidade/métodos , Espectrometria de Massas/métodos , Pró-Proteína Convertase 9/sangue , Anticorpos Imobilizados/química , Anticorpos Monoclonais/química , Humanos , Imãs/química , Pró-Proteína Convertase 9/análise
16.
Clin Chim Acta ; 459: 155-161, 2016 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27259466

RESUMO

Reports of mass spectrometry based assays for peptides and proteins have become increasingly common in the literature. The growing interest of mass spectrometry for use in clinical laboratories has been primarily driven by the inherent selectivity of the platform relative to more traditional platforms such as immunoassays. However, the adoption of mass spectrometry for peptide and protein analysis in the clinic has been relatively slow compared its adoption in non-clinical laboratories such as in biomarker discovery efforts or within laboratories that support pharmaceutical and academic research. Here, we review some of the successful reports of MS based assays for human proteins in multiple stages of assay research, and describe how and why the platform was employed in order to demonstrate where and when mass spectrometry based assays will have value in the future.


Assuntos
Espectrometria de Massas , Proteínas/análise , Biomarcadores/análise , Biomarcadores/metabolismo , Humanos , Cinética , Proteínas/metabolismo
17.
Bioanalysis ; 8(12): 1265-77, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27225968

RESUMO

AIM: A traditional oral fatty acid challenge assesses absorption of triacylglycerol (TG) into the periphery through the intestines, but cannot distinguish the composition or source of fatty acid in the TG. Stable isotope-labeled tracers combined with LC-MRM can be used to identify and distinguish TG synthesized with dietary and stored fatty acids. RESULTS: Concentrations of three abundant TGs (52:2, 54:3 and 54:4) were monitored for incorporation of one or two (2)H11-oleate molecules per TG. This method was subjected to routine assay validation and meets typical requirements for an assay to be used to support clinical studies. CONCLUSION: Calculations for the fractional appearance rate of TG in plasma are presented along with the intracellular enterocyte precursor pool for 12 study participants.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Mucosa Intestinal/metabolismo , Triglicerídeos/análise , Adolescente , Adulto , Deutério/análise , Dieta , Humanos , Marcação por Isótopo/métodos , Masculino , Ácido Oleico/análise , Ácido Oleico/sangue , Ácido Oleico/metabolismo , Triglicerídeos/sangue , Triglicerídeos/metabolismo , Adulto Jovem
18.
Bioanalysis ; 8(7): 611-23, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26964649

RESUMO

BACKGROUND: Pathogenic Clostridium difficile produces two proinflammatory exotoxins, toxin A and toxin B. Low level of serum antitoxin IgG antibodies is a risk factor for the development of primary and recurrent C. difficile infection (CDI). RESULTS: We developed and validated two sensitive, titer-based electrochemiluminescence assays for the detection of serum antibody levels against C. difficile toxins A and B. These assays demonstrated excellent precision. The sensitivity of the assays allowed the detection of antitoxin A and antitoxin B IgG antibodies in all tested serum samples during assay validation. CONCLUSION: The validated titer-based assays enable assessment of antitoxin A and antitoxin B IgG antibodies as potential biomarkers to identify patients with CDI at increased risk for CDI recurrence.


Assuntos
Proteínas de Bactérias/imunologia , Toxinas Bacterianas/imunologia , Clostridioides difficile/metabolismo , Enterotoxinas/imunologia , Imunoglobulina G/sangue , Medições Luminescentes , Anticorpos Antibacterianos/sangue , Biomarcadores/sangue , Infecções por Clostridium/diagnóstico , Voluntários Saudáveis , Humanos , Medições Luminescentes/normas , Controle de Qualidade
19.
Clin Chem ; 62(1): 227-35, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26430077

RESUMO

BACKGROUND: Proglucagon-derived peptides (PGDPs), which include glucagon-like peptide (GLP)-1, glucagon, and oxyntomodulin, are key regulators of glucose homeostasis and satiety. These peptide hormones are typically measured with immuno-based assays (e.g., ELISA, RIA), which often suffer from issues of selectivity. METHODS: We developed a multiplexed assay for measuring PGDPs including GLP-1 (7-36) amide, GLP-1 (9-36) amide, glucagon, and oxyntomodulin by mass spectrometry and used this assay to examine the effect of a meal tolerance test on circulating concentrations of these hormones. Participants fasted overnight and were either given a meal (n = 8) or continued to fast (n = 4), with multiple blood collections over the course of 3 h. Plasma samples were analyzed by microflow immunoaffinity (IA)-LC-MS/MS with an isotope dilution strategy. RESULTS: Assay performance characteristics were examined and established during analytical validation for all peptides. Intra- and interassay imprecision were found to be 2.2%-10.7% and 6.8%-22.5%, respectively. Spike recovery was >76%, and dilution linearity was established up to a 16-fold dilution. Immediately after the meal tolerance test, GLP-1 and oxyntomodulin concentrations increased and had an almost identical temporal relationship, and glucagon concentrations increased with a slight delay. CONCLUSIONS: IA-LC-MS/MS was used for the simultaneous and selective measurement of PGDPs. This work includes the first indication of the physiological concentrations and modulation of oxyntomodulin after a meal.


Assuntos
Jejum , Peptídeo 1 Semelhante ao Glucagon/sangue , Glucagon/sangue , Imunoensaio , Oxintomodulina/sangue , Espectrometria de Massas em Tandem , Animais , Cromatografia Líquida de Alta Pressão , Glucagon/imunologia , Peptídeo 1 Semelhante ao Glucagon/imunologia , Humanos , Camundongos , Camundongos Endogâmicos BALB C , Oxintomodulina/imunologia
20.
Bioanalysis ; 7(23): 3019-34, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26627049

RESUMO

The 2015 9th Workshop on Recent Issues in Bioanalysis (9th WRIB) took place in Miami, Florida with participation of over 600 professionals from pharmaceutical and biopharmaceutical companies, biotechnology companies, contract research organizations and regulatory agencies worldwide. It is once again a 5-day week long event - a full immersion bioanalytical week - specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest in bioanalysis. The topics covered included both small and large molecules, and involved LCMS, hybrid LBA/LCMS, LBA approaches including the focus on biomarkers and immunogenicity. This 2015 White Paper encompasses recommendations that emerged from the extensive discussions held during the workshop, and is aimed at providing the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to advance scientific excellence, improve quality and deliver better regulatory compliance. Due to its length, the 2015 edition of this comprehensive White Paper has been divided into three parts. Part 2 covers the recommendations for hybrid LBA/LCMS and regulatory agencies' inputs. Part 1 (small molecule bioanalysis using LCMS) and Part 3 (large molecule bioanalysis using LBA, biomarkers and immunogenicity) will be published in volume 7 of Bioanalysis, issues 22 and 24, respectively.


Assuntos
Biomarcadores/química , Biofarmácia/organização & administração , Biotecnologia/organização & administração , História do Século XXI , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...