Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Prosthet Dent ; 123(1): 85-95, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30982616

RESUMO

STATEMENT OF PROBLEM: Complete-arch digital scans are becoming popular as digital dentistry is adopted for expanded clinical situations such as complete-arch prostheses, removable prostheses, extensive implant-supported treatment, and orthodontic aligners. Whether the scan pattern technique affects the trueness and precision of complete-arch scans and whether differences in accuracy exist among different scanners remain unclear. Furthermore, each manufacturer recommends a different scan pattern, but evidence of the superiority of the manufacturer's recommended pattern is lacking. PURPOSE: The purpose of this in vitro study was to determine whether the scan pattern affects the trueness, precision, and speed of complete-arch digital scans performed by using 4 different digital scanning systems. MATERIAL AND METHODS: A custom model used as the reference standard was fabricated with teeth having the same refractive index as dentin and enamel to simulate the natural dentition. The scan of the custom typodont was obtained by using an ATOS III Triple Scan 3D optical scanner. This study evaluated the CEREC Omnicam, Planmeca Emerald, Align iTero Element, and 3Shape TRIOS 3. Experimental scans were obtained from each of the 4 different digital scanning systems by using 4 unique scan patterns by experienced clinicians. Four experimental scans were acquired from each of the scanners by using 4 distinct scan patterns for a total of 16 scans for each scanner. Scan patterns 1 to 4 were based on the operator manuals for each different scanner. The scan time was recorded for each scan. All experimental scans were converted to standard tessellation language (STL) format, and a comprehensive metrology program, Geomagic Control X, was used to compare the reference standard scan with the experimental scans. RESULTS: For trueness, the scanner (P<.001), scan pattern (P=.001), and their interaction (P<.001) were found to be significant. Overall, scan pattern 2 showed the highest average trueness and precision. Likewise, for overall scan pattern precision, the scanner, scan pattern, and their interaction were found to be significant (P<.001). CONCLUSIONS: Scan pattern affected trueness and precision for some scanners, but not for others. Differences exist in the complete-arch scan speed, trueness, and precision of individual scanners. Scan pattern can play an important role in the success of digital scanning.


Assuntos
Técnica de Moldagem Odontológica , Boca Edêntula , Desenho Assistido por Computador , Arco Dental , Humanos , Imageamento Tridimensional , Modelos Dentários
2.
Orthod Craniofac Res ; 22 Suppl 1: 168-174, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31074138

RESUMO

OBJECTIVE: This study aimed to determine how the accuracy of digital impressions was affected by four common dental substrates using seven prevalent IOS systems to scan the complete arch of a human maxilla. SETTING AND SAMPLE POPULATION: The Department of Oral Rehabilitation at the Medical University of South Carolina. A single cadaver maxilla. MATERIALS AND METHODS: Seven digital intraoral impression systems were used to scan a freshly harvested human maxilla. The maxilla contained several teeth restored with amalgam and composite, as well as unrestored teeth characterized by enamel. Also, three teeth were prepared for full coverage restorations to expose natural dentin. An industrial grade metrology software program that allowed 3D overlay and dimensional computation compared deviations of the complete arch and its substrates on the test model from the reference model. RESULTS: Substrates were significantly different from each other when considering scan data as a whole, as well as when comparing IOS devices individually. Only PlanScan failed to reveal trueness differences between the different substrates, while only Emerald revealed precision differences between the substrates. CONCLUSIONS: Substrate type does impact the overall accuracy of intraoral scans with dentin being the most accurate and enamel being the least accurate. The four substrates scanned impacted the trueness of all IOS devices.


Assuntos
Técnica de Moldagem Odontológica , Maxila , Desenho Assistido por Computador , Arco Dental , Materiais para Moldagem Odontológica , Humanos , Imageamento Tridimensional , Modelos Dentários
3.
New Phytol ; 221(3): 1289-1302, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30368816

RESUMO

Viruses that infect photoautotrophs have a fundamental relationship with light, given the need for host resources. We investigated the role of light on Coccolithovirus (EhV) infection of the globally distributed coccolithophore, Emiliania huxleyi. Light was required for EhV adsorption, and viral production was highest when host cultures were maintained in continuous light or at irradiance levels of 150-300 µmol m-2  s-1 . During the early stages of infection, photosynthetic electron transport remained high, while RuBisCO expression decreased concomitant with an induction of the pentose phosphate pathway, the primary source of de novo nucleotides. A mathematical model developed and fitted to the laboratory data supported the hypothesis that EhV replication was controlled by a trade-off between host nucleotide recycling and de novo synthesis, and that photoperiod and photon flux could toggle this switch. Laboratory results supported field observations that light was the most robust driver of EhV replication within E. huxleyi populations collected across a 2000 nautical mile transect in the North Atlantic. Collectively, these findings demonstrate that light can drive host-virus interactions through a mechanistic interplay between host metabolic processes, which serve to structure infection and phytoplankton mortality in the upper ocean.


Assuntos
Haptófitas/efeitos da radiação , Haptófitas/virologia , Interações Hospedeiro-Patógeno/efeitos da radiação , Luz , Phycodnaviridae/fisiologia , Adsorção , Haptófitas/crescimento & desenvolvimento , NADP/metabolismo , Nucleotídeos/biossíntese , Via de Pentose Fosfato/efeitos da radiação , Fotoperíodo , Fotossíntese/efeitos da radiação
4.
J Endod ; 42(8): 1218-25, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27372159

RESUMO

INTRODUCTION: The lack of mechanical debridement and reduced concentrations suggested for chemical debridement to maintain stem cell viability call into question the disinfection efficacy of current regenerative protocols. Current protocols vary in the concentration and type of antibiotic medicaments used. The aim of this study was to determine if simulated immature teeth infected with Enterococcus faecalis can be completely disinfected by following current standardized regenerative protocols and to evaluate the probable effects of residual bacteria on stem cell toxicity. METHODS: Sixty-eight caries-free maxillary incisors were used. S1 sampling protocols were validated in both negative and positive control groups via culture, scanning electron microscopy, and confocal laser scanning microscopy. All teeth, except the negative controls, were inoculated with E. faecalis. The teeth were divided into the following groups: group 1, triple antibiotic paste (ciprofloxacin:metronidazole:minocycline) at concentrations of 10, 1, and 0.1 mg/mL; group 2, double antibiotic paste (ciprofloxacin:metronidazole) at concentrations of 10, 1, and 0.1 mg/mL; group 3: Ultracal XS calcium hydroxide (Ultradent, St Louis, MO); and controls, negative and positive controls. Current regenerative protocols recommended by the American Association of Endodontists were followed. S2 sampling was performed after 4 weeks and tested for bacterial presence via culturing, scanning electron microscopy, and confocal laser scanning microscopic analysis. RESULTS: The data showed that calcium hydroxide and the current recommended antibiotic concentrations are not capable of completely eliminating bacteria from simulated necrotic immature permanent teeth. CONCLUSIONS: Overall, this study focuses on the need to re-evaluate the balance between stem cell toxicity and bacterial elimination in order to determine the appropriate concentrations and medicaments for successful regenerative endodontic procedures.


Assuntos
Antibacterianos/administração & dosagem , Necrose da Polpa Dentária/tratamento farmacológico , Necrose da Polpa Dentária/microbiologia , Desinfecção/métodos , Hidróxido de Cálcio , Ciprofloxacina/administração & dosagem , Desbridamento , Cavidade Pulpar , Necrose da Polpa Dentária/cirurgia , Dentição Permanente , Combinação de Medicamentos , Enterococcus faecalis , Humanos , Técnicas In Vitro , Incisivo , Metronidazol/administração & dosagem , Microscopia Confocal , Microscopia Eletrônica de Varredura , Minociclina/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...