Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 829
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38841916

RESUMO

BACKGROUND: Residual transprosthetic gradient (TG) after transcatheter aortic valve replacement (TAVR) with balloon-expandable valves (BEV) may be due to suboptimal valve expansion. AIMS: To compare hemodynamics after TAVR with small BEV according to postdilation strategy. METHODS: This observational, retrospective cohort study included 184 consecutive patients from a single center treated with 23 mm Sapien 3 Ultra (Edwards Lifesciences) BEV implantation in the aortic position and enrolled between January 2020 and April 2023. Patients treated with routine postdilation (RP, n = 73) were compared to patients treated according to local standard practice (SP, n = 111). Primary endpoint was 30-day mean TG. Secondary endpoints were incidence of 30-day prosthesis-patient mismatch (PPM), technical success and device success. RESULTS: Thirty-day mean TG was lower in RP versus SP (12.3 ± 4.6 mmHg vs. 14.1 ± 5.7 mmHg, p = 0.031), and incidence of PPM was less common with RP versus SP (47.3% vs. 71.0%, p = 0.006). Technical success (98.6% vs. 99.1%, p = 0.637) and device success (93.1% vs. 90.1%, p = 0.330) did not differ between groups. Differences in 30-day mean TG were driven by patients at normal flow (12.1 ± 4.0 mmHg vs. 15.0 ± 5.5 mmHg, p = 0.014), while no differences were evident among patients at low flow (12.5 ± 5.5 mmHg vs. 11.7 ± 5.5 mmHg, p = 0.644). RP decreased height and increased width of BEV, and a linear regression established that final BEV width could predict 30-day mean TG (r = -0.6654, p < 0.0001). CONCLUSIONS: RP after TAVR with small BEV was associated with more favorable forward-flow hemodynamics than SP.

2.
Struct Heart ; 8(3): 100277, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38799801

RESUMO

Inferior outcomes with ACURATE neo, a self-expanding transcatheter heart valve (THV) for the treatment of severe aortic stenosis, were mainly driven by higher rates of moderate/severe paravalvular leak (PVL). To overcome this limitation, the next-generation ACURATE neo2 features a 60% larger external sealing skirt. Data on long-term performance are limited; however, clinical evidence suggests improved short-term performance which is comparable to contemporary THVs. This report reviews data on short-term clinical and echocardiographic outcomes of ACURATE neo2. A PubMed search yielded 13 studies, including 5 single arm and 8 nonrandomized comparative studies with other THVs which reported in-hospital or 30-day clinical and echocardiographic outcomes. In-hospital or 30-day all-cause mortality was ≤3.3%, which is comparable to other contemporary THVs. The rates of postprocedural ≧moderate PVL ranged 0.6%-4.7%. In multicenter propensity-matched analyses, neo2 significantly reduced the rate of ≧moderate PVL compared to neo (3.5% vs. 11.3%, p < 0.01), whereas rates were comparable to Evolut Pro/Pro+ (Neo2: 2.0% vs. Pro/Pro+: 3.1%, p = 0.28) and SAPIEN 3 Ultra (Neo2: 0.6% vs. Ultra: 1.1%, p = 0.72). The rate of permanent pacemaker implantation with neo2 was consistently low (3.3%-8.6%) except in one study, and in propensity-matched analyses were significantly lower than Evolut Pro/Pro+ (6.7% vs. 16.7%, p < 0.01), and comparable to SAPIEN 3 Ultra (8.1% vs. 10.3%, p = 0.29). In conclusion, ACURATE neo2 showed better short-term performance by considerably reducing PVL compared to its predecessor, with short-term clinical and echocardiographic outcomes comparable to contemporary THVs.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38752971

RESUMO

BACKGROUND: The safety profile of transcatheter tricuspid valve (TTV) repair techniques is well established, but residual tricuspid regurgitation (TR) remains a concern. OBJECTIVES: The authors sought to assess the impact of residual TR severity post-TTV repair on survival. METHODS: We evaluated the survival rate at 2 years of 613 patients with severe isolated functional TR who underwent TTV repair in TRIGISTRY according to the severity of residual TR at discharge using a 3-grade (mild, moderate, and severe) or 4-grade scheme (mild, mild to moderate, moderate to severe, and severe). RESULTS: Residual TR was none/mild in 33%, moderate in 52%, and severe in 15%. The 2-year adjusted survival rates significantly differed between the 3 groups (85%, 70%, and 44%, respectively; restricted mean survival time [RMST]: P = 0.0001). When the 319 patients with moderate residual TR were subdivided into mild to moderate (n = 201, 33%) and moderate to severe (n = 118, 19%), the adjusted survival rate was also significantly different between groups (85%, 80%, 55%, and 44%, respectively; RMST: P = 0.001). Survival was significantly lower in patients with moderate to severe residual TR compared to patients with mild to moderate residual TR (P = 0.006). No difference in survival rates was observed between patients with no/mild and mild to moderate residual TR (P = 0.67) or between patients with moderate to severe and severe residual TR (P = 0.96). CONCLUSIONS: The moderate residual TR group was heterogeneous and encompassed patients with markedly different clinical outcomes. Refining TR grade classification with a more granular 4-grade scheme improved outcome prediction. Our results highlight the importance of achieving a mild to moderate or lower residual TR grade during TTV repair, which could define a successful intervention.

4.
J Am Coll Cardiol ; 83(20): 2002-2014, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38749619

RESUMO

Orthotopic transcatheter tricuspid valve replacement (TTVR) devices have been shown to be highly effective in reducing tricuspid regurgitation (TR), and interest in this therapy is growing with the recent commercial approval of the first orthotopic TTVR. Recent TTVR studies report preexisting cardiac implantable electronic device (CIED) transvalvular leads in ∼35% of patients, with entrapment during valve implantation. Concerns have been raised regarding the safety of entrapping leads and counterbalanced against the risks of transvenous lead extraction (TLE) when indicated. This Heart Valve Collaboratory consensus document attempts to define the patient population with CIED lead-associated or lead-induced TR, describe the risks of lead entrapment during TTVR, delineate the risks and benefits of TLE in this setting, and develop a management algorithm for patients considered for TTVR. An electrophysiologist experienced in CIED management should be part of the multidisciplinary heart team and involved in shared decision making.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Índice de Gravidade de Doença
5.
Artigo em Inglês | MEDLINE | ID: mdl-38626921

RESUMO

Intraprocedural multimodality imaging, combining TEE with CT-fluoro fusion and ICE, can promote TTVR procedural success by improved guidance of critical steps of the device implantation.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38578944

RESUMO

AIMS: The atherosclerotic profile and advanced plaque subtype burden in symptomatic patients ≤45 years old have not been established. This study aimed to assess the prevalence and predictors of coronary artery calcium (CAC), plaque subtypes, and plaque burden by coronary computed tomography angiography (CCTA) in symptomatic young patients. METHODS AND RESULTS: We included 907 symptomatic young patients (18-45 years) from Montefiore undergoing CCTA for chest pain evaluation. Prevalence and predictors of CAC, plaque subtypes, and burden were evaluated using semi-automated software. In the overall population (55% female and 44% Hispanic), 89% had CAC = 0. The likelihood of CAC or any plaque by CCTA increased with >3 risk factors (RF, OR 7.13 [2.14-23.7] and OR 10.26 [3.36-31.2], respectively). Any plaque by CCTA was present in 137 (15%); the strongest independent predictors were age ≥35 years (OR 3.62 [2.05-6.41]) and family history of premature CAD (FHx) (OR 2.76 [1.67-4.58]). Stenosis ≥50% was rare (1.8%), with 31% of those having CAC = 0. Significant non-calcified (NCP, 37.2%) and low-attenuation (LAP, 4.24%) plaque burdens were seen, even in those with non-obstructive stenosis. Among patients with CAC = 0, 5% had plaque, and the only predictor of exclusively non-calcified plaque was FHx (OR 2.29 [1.08-4.86]). CONCLUSIONS: In symptomatic young patients undergoing CCTA, the prevalence of CAC or any coronary atherosclerosis was not negligible, and the likelihood increased with RF burden. The presence of coronary stenosis ≥50% was rare and most often accompanied by CAC > 0 but there was a significant burden of NCP and LAP even within the non-obstructive group.

7.
Eur J Heart Fail ; 26(4): 1065-1077, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38606485

RESUMO

AIMS: Patients with heart failure and mildly reduced or preserved ejection fraction have limited therapeutic options. The ALT-FLOW Early Feasibility Study evaluated safety, haemodynamics and outcomes for the APTURE transcatheter shunt system, a novel left atrium to coronary sinus shunt in these patients. METHODS AND RESULTS: Safety and shunt implantation success was evaluated for all 116 enrolled patients. An analysis population of implanted patients with a left ventricular ejection fraction (LVEF) >40% (n = 95) was chosen to assess efficacy via paired comparison between baseline and follow-up haemodynamic (3 and 6 months), and echocardiographic, clinical and functional outcomes (6 months and 1 year). Health status and quality of life outcomes were assessed using the Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-OSS). The primary safety endpoint, major adverse cardiac, cerebral, and renal events, and reintervention through 30 days, occurred in 3/116 patients (2.6%). All implanted shunts were patent at 1 year. In patients with LVEF >40%, the mean (95% confidence interval) reduction in exercise pulmonary capillary wedge pressure (PCWP) at 20 W was -5.7 (-8.6, -2.9) mmHg at 6 months (p < 0.001). At baseline, 8% had New York Heart Association class I-II status and improved to 68% at 1 year (p < 0.001). KCCQ-OSS at baseline was 39 (35, 43) and improved at 6 months and 1 year by 25 (20-30) and 27 (22-32) points, respectively (both p < 0.0001). No adverse changes in haemodynamic and echocardiographic indices of right heart function were observed at 1 year. Overall, the reduction in PCWP at 20 W and improvement in KCCQ-OSS in multiple subgroups were consistent with those observed for the entire population. CONCLUSIONS: In patients with heart failure and LVEF >40%, the APTURE shunt demonstrated an acceptable safety profile with significant sustained improvements in haemodynamic and patient-centred outcomes, underscoring the need for further evaluation of the APTURE shunt in a randomized trial.


Assuntos
Seio Coronário , Estudos de Viabilidade , Átrios do Coração , Insuficiência Cardíaca , Volume Sistólico , Humanos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/terapia , Feminino , Masculino , Volume Sistólico/fisiologia , Idoso , Átrios do Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Seio Coronário/fisiopatologia , Resultado do Tratamento , Pessoa de Meia-Idade , Ecocardiografia/métodos , Qualidade de Vida , Cateterismo Cardíaco/métodos , Estudos Prospectivos , Função Ventricular Esquerda/fisiologia , Seguimentos , Hemodinâmica/fisiologia
8.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599688

RESUMO

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Estudos Multicêntricos como Assunto , Sistema de Registros
9.
Int J Cardiol ; 405: 131934, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38437953

RESUMO

AIMS: T-TEER is an effective therapy for the treatment of tricuspid regurgitation (TR). However, the effects of leaflets clipping on tricuspid valve annulus (TA) have not been investigated in detail. The aim of this study is to investigate the effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on TA diameter. METHODS AND RESULTS: The TriValve registry (Transcatheter Tricuspid Valve Therapies, NCT03416166) collected 556 patients from 22 European and North American centres undergoing transcatheter tricuspid valve interventions from 2016 to 2022. Patients undergoing T-TEER with available pre- and post-procedural data on TA diameter measured in the apical 4-chamber view on transthoracic echocardiography were selected for this study. Primary end-point was the reduction of TA diameter after T-TEER. A total of 186 patients were included in the study. In 115 patients (62%) TA diameter was reduced by at least 1 mm as compared to baseline. A significant reduction of TA dimension was observed following T-TEER (mean 2.3 mm [from pre-procedural diameter 46.7 mm to post-procedural diameter 44.4 mm], p < 0.001). In particular, the greatest reduction was observed in those with T-TEER in antero-septal commissure (mean 2.7 mm [from 47.1 mm to 44.4 mm], p < 0.001) as compared to those combining both antero-septal and postero-septal commissures (mean 1.4, from 46.0 mm to 44.6 mm, P = 0.06). A significant reduction of TA dimension was recorded in patients with 1 or 2 clips implanted but not in those patients with ≥3 clips implanted. CONCLUSIONS: In almost two third of patients T-TEER reduces TA diameter in addition to leaflet approximation. CONDENSED ABSTRACT: The effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on tricuspid valve annulus (TA) have not been studied in details. This study investigates TA diameter as measured in apical 4-chamber view on transthoracic echocardiography before and after T-TEER. A total of 186 patients from the TriValve registry were included in the study. The study results show that 62% of patients have a TA reduction after T-TEER, especially in those receiving 1 or 2 clips in the antero-septal commissure. These suggest that T-TEER reduces tricuspid regurgitation not only by approximation of leaflets, but also by TA diameter reduction.


Assuntos
Cateterismo Cardíaco , Sistema de Registros , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Masculino , Feminino , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Idoso , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos , Pessoa de Meia-Idade , Ecocardiografia/métodos
10.
JAMA ; 331(12): 1015-1024, 2024 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-38460161

RESUMO

Importance: Drug-coated balloons offer a potentially beneficial treatment strategy for the management of coronary in-stent restenosis. However, none have been previously evaluated or approved for use in coronary circulation in the United States. Objective: To evaluate whether a paclitaxel-coated balloon is superior to an uncoated balloon in patients with in-stent restenosis undergoing percutaneous coronary intervention. Design, Setting, and Participants: AGENT IDE, a multicenter randomized clinical trial, enrolled 600 patients with in-stent restenosis (lesion length <26 mm and reference vessel diameter >2.0 mm to ≤4.0 mm) at 40 centers across the United States between May 2021 and August 2022. One-year clinical follow-up was completed on October 2, 2023. Interventions: Participants were randomized in a 2:1 allocation to undergo treatment with a paclitaxel-coated (n = 406) or an uncoated (n = 194) balloon. Main Outcomes and Measures: The primary end point of 1-year target lesion failure-defined as the composite of ischemia-driven target lesion revascularization, target vessel-related myocardial infarction, or cardiac death-was tested for superiority. Results: Among 600 randomized patients (mean age, 68 years; 157 females [26.2%]; 42 Black [7%], 35 Hispanic [6%] individuals), 574 (95.7%) completed 1-year follow-up. The primary end point at 1 year occurred in 17.9% in the paclitaxel-coated balloon group vs 28.6% in the uncoated balloon group, meeting the criteria for superiority (hazard ratio [HR], 0.59 [95% CI, 0.42-0.84]; 2-sided P = .003). Target lesion revascularization (13.0% vs 24.7%; HR, 0.50 [95% CI, 0.34-0.74]; P = .001) and target vessel-related myocardial infarction (5.8% vs 11.1%; HR, 0.51 [95% CI, 0.28-0.92]; P = .02) occurred less frequently among patients treated with paclitaxel-coated balloon. The rate of cardiac death was 2.9% vs 1.6% (HR, 1.75 [95% CI, 0.49-6.28]; P = .38) in the coated vs uncoated balloon groups, respectively. Conclusions and Relevance: Among patients undergoing coronary angioplasty for in-stent restenosis, a paclitaxel-coated balloon was superior to an uncoated balloon with respect to the composite end point of target lesion failure. Paclitaxel-coated balloons are an effective treatment option for patients with coronary in-stent restenosis. Trial Registration: ClinicalTrials.gov Identifier: NCT04647253.


Assuntos
Reestenose Coronária , Infarto do Miocárdio , Feminino , Humanos , Idoso , Paclitaxel , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Stents , Resultado do Tratamento , Morte
12.
JACC Cardiovasc Interv ; 17(5): 666-677, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38479966

RESUMO

BACKGROUND: Acute ischemic stroke remains a serious complication of transcatheter aortic valve replacement (TAVR). Cerebral embolic protection devices (CEPD) were developed to mitigate the risk of acute ischemic stroke complicating TAVR (AISCT). However, the existing body of evidence does not clearly support CEPD efficacy in AISCT prevention. OBJECTIVES: In a cohort of patients with AISCT, we aimed to compare the characteristics and outcomes of patients who have had unprotected TAVR (CEPD-) vs CEPD-protected TAVR (CEPD+). METHODS: Data were derived from an international multicenter registry focusing on AISCT. We included all patients who experienced ischemic stroke within 72 hours of TAVR. Stroke severity was assessed using the National Institutes of Health Stroke Scale (NIHSS). Primary outcomes were neurologic disability status according to the modified Rankin Score at 30 days, and 6-month all-cause death. Propensity score matched analysis was used to control for differences between groups. RESULTS: In 18,725 TAVR procedures, 416 AISCT (2.2%) within 72 hours were documented, of which 376 were in the CEPD- TAVR group and 40 in the CEPD+ TAVR group. Although the middle cerebral artery stroke rate was similar in both groups (29.7% CEPD- vs 33.3% CEPD+; P = 0.71), AISCT in the CEPD+ group was characterized by a lower rate of internal carotid artery occlusion (0% vs 4.7%) and higher rate of vertebrobasilar system strokes (15.4% vs 5.7%; P = 0.04). AISCT was severe (NIHSS ≥15) in 21.6% CEPD- and 23.3% CEPD+ AISCT (P = 0.20). Disabling stroke rates (modified Rankin Score >1 at 30 days) were 47.3% vs 42.5% (P = 0.62), and 6-month mortality was 31.3% vs 23.3% (P = 0.61), in the CEPD- and CEPD+ groups, respectively. In the propensity score matched cohort, disabling stroke rates were 56.5% vs 41.6% (P = 0.16), and 6-month mortality was 33% vs 19.5% (P = 0.35), in the CEPD- and CEPD+ groups, respectively. CONCLUSIONS: In a large cohort of patients with AISCT, the use of CEPD had little effect on stroke distribution, severity, and outcomes.


Assuntos
Estenose da Valva Aórtica , Dispositivos de Proteção Embólica , AVC Isquêmico , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , AVC Isquêmico/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
13.
JACC Cardiovasc Interv ; 17(6): 742-752, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38538170

RESUMO

BACKGROUND: Coronary obstruction (CO) is a potentially life-threatening complication of transcatheter aortic valve replacement (TAVR). Chimney stenting or leaflet laceration with transcatheter electrosurgery (Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction [BASILICA]) are 2 techniques developed to prevent CO. OBJECTIVES: The aim of the present study was to compare periprocedural and 1-year outcomes of chimney and BASILICA in TAVR patients at high risk of CO. METHODS: This multicenter observational registry enrolled consecutive TAVR patients at high risk of CO, undergoing either preventive chimney stenting or BASILICA. Clinical success was defined as successful performance of the chimney or BASILICA technique without clinically relevant ostial CO. The primary endpoint was major adverse cardiovascular events, a composite of death, myocardial infarction, stroke, or unplanned target lesion coronary revascularization at 1 year. RESULTS: A total of 168 patients were included: 71 (42.3%) received chimney stenting, and 97 (57.7%) underwent BASILICA. Patients undergoing BASILICA had higher preprocedural risk of CO, as indicated by lower sinotubular junction height (18.2 ± 4.8 mm vs 14.8 ± 3.4 mm; P < 0.001) and diameter (28.2 ± 4.5 vs 26.8 ± 3.4; P = 0.029). Rates of periprocedural complications were similar between the 2 groups. Clinical success was 97.2% and 96.9% in chimney and BASILICA, respectively (P = 0.92). At 1-year follow-up, the cumulative incidence of major adverse cardiovascular events was 18.7% (95% CI: 11%-30.6%) in the chimney group and 19.9% (95% CI: 12.1%-31.5%) in the BASILICA group (log-rank P = 0.848), whereas chimney was associated with a numerically higher cardiovascular mortality than BASILICA (6.7% vs 1.3%; log-rank P = 0.168). CONCLUSIONS: Chimney stenting and BASILICA effectively prevent TAVR-induced acute CO. Both techniques seem to have comparable acceptable periprocedural and 1-year outcomes.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Próteses Valvulares Cardíacas , Lacerações , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Lacerações/complicações , Lacerações/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Oclusão Coronária/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Desenho de Prótese
14.
JACC Cardiovasc Interv ; 17(4): 552-560, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38418058

RESUMO

BACKGROUND: Transcatheter tricuspid valve replacement (TTVR) abolishes tricuspid regurgitation (TR) and has emerged as a definitive treatment for TR. OBJECTIVES: The purpose of this multicenter, observational study was to determine the clinical characteristics and short-term outcomes of patients with TR screened for TTVR. METHODS: Patients underwent TTVR screening at 7 centers on a compassionate-use basis. The primary endpoints were NYHA functional class and TR grade at 30-day follow-up. Secondary endpoints included all-cause mortality, heart failure hospitalization, technical success, and reasons for TTVR screening failure. RESULTS: A total of 149 patients (median age 79 years [Q1-Q3: 72-84 years], 54% women) underwent TTVR screening. The TTVR screening failure rate was 74%, mainly related to large tricuspid annular diameter. Patients undergoing TTVR (n = 38) had significant functional improvements (NYHA functional class I or II from 21% to 68%; P < 0.001), with TR ≤1+ in 97% at 30-day follow-up (P < 0.001 from baseline). Technical success was achieved in 91%, with no intraprocedural mortality or conversion to surgery. At 30-day follow-up, mortality was 8%, heart failure hospitalization 5%, major bleeding 18%, and reintervention 9%. Patients who failed screening for TTVR and subsequently underwent "bailout" transcatheter edge-to-edge repair (n = 26) had favorable outcomes (NYHA functional class I or II from 27% to 58%; P < 0.001), with TR ≤1+ in 43% at 30-day follow-up (P < 0.001 from baseline). CONCLUSIONS: This first real-world report of TTVR screening demonstrated a high screening failure rate, mainly related to large tricuspid annular diameter. Patients undergoing TTVR had superior TR reduction and symptom alleviation compared with bailout tricuspid transcatheter edge-to-edge repair, at the cost of greater procedural complications.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso , Masculino , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Recuperação de Função Fisiológica , Fatores de Tempo , Índice de Gravidade de Doença , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Sistema de Registros
16.
J Cardiovasc Comput Tomogr ; 18(1): 50-55, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38314547

RESUMO

BACKGROUND: Computed tomography aortic valve calcium (AVC) score has accepted value for diagnosing and predicting outcomes in aortic stenosis (AS). Multi-energy CT (MECT) allows virtual non-contrast (VNC) reconstructions from contrast scans. We aim to compare the VNC-AVC score to the true non-contrast (TNC)-AVC score for assessing AS severity. METHODS: We prospectively included patients undergoing a MECT for transcatheter aortic valve replacement (TAVR) planning. TNC-AVC was acquired before contrast, and VNC-AVC was derived from a retrospectively gated contrast-enhanced scan. The Agatston scoring method was used for quantification, and linear regression analysis to derive adjusted-VNC values. RESULTS: Among 109 patients (55% female) included, 43% had concordant severe and 14% concordant moderate AS. TNC scan median dose-length product was 116 â€‹mGy∗cm. The median TNC-AVC was 2,107 AU (1,093-3,372), while VNC-AVC was 1,835 AU (1293-2,972) after applying the coefficient (1.46) and constant (743) terms. A strong correlation was demonstrated between methods (r â€‹= â€‹0.93; p â€‹< â€‹0.001). Using accepted thresholds (>1,300 AU for women and >2,000 AU for men), 65% (n â€‹= â€‹71) of patients had severe AS by TNC-AVC and 67% (n â€‹= â€‹73) by adjusted-VNC-AVC. After estimating thresholds for adjusted-VNC (>1,564 AU for women and >2,375 AU for men), 56% (n â€‹= â€‹61) had severe AS, demonstrating substantial agreement with TNC-AVC (κ â€‹= â€‹0.77). CONCLUSIONS: MECT-derived VNC-AVC showed a strong correlation with TNC-AVC. After adjustment, VNC-AVC demonstrated substantial agreement with TNC-AVC, potentially eliminating the requirement for an additional scan and enabling reductions in both radiation exposure and acquisition time.


Assuntos
Estenose da Valva Aórtica , Tomografia Computadorizada por Raios X , Masculino , Humanos , Feminino , Estudos Retrospectivos , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Constrição Patológica , Cálcio
17.
Am J Cardiol ; 219: 60-70, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38401656

RESUMO

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Fatores Sexuais , Idoso de 80 Anos ou mais , Idoso , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Valva Aórtica/cirurgia
18.
EuroIntervention ; 20(2): e117-e119, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38224257
19.
JACC Case Rep ; 29(2): 102157, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38264301

RESUMO

Dynamic left ventricular outflow obstruction is a rare but severe complication of transcatheter aortic valve replacement. It presents as a paradoxical hemodynamic collapse after relieving the left ventricular afterload. Considering its unique pathophysiology, this entity dictates counterintuitive treatments. We describe a case of left ventricular outflow obstruction treated with venoarterial extracorporeal membrane oxygenation and discuss its management principles.

20.
Eur Heart J ; 45(8): 586-597, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-37624856

RESUMO

BACKGROUND AND AIMS: Benefit of tricuspid regurgitation (TR) correction and timing of intervention are unclear. This study aimed to compare survival rates after surgical or transcatheter intervention to conservative management according to a TR clinical stage as assessed using the TRI-SCORE. METHODS: A total of 2,413 patients with severe isolated functional TR were enrolled in TRIGISTRY (1217 conservatively managed, 551 isolated tricuspid valve surgery, and 645 transcatheter valve repair). The primary endpoint was survival at 2 years. RESULTS: The TRI-SCORE was low (≤3) in 32%, intermediate (4-5) in 33%, and high (≥6) in 35%. A successful correction was achieved in 97% and 65% of patients in the surgical and transcatheter groups, respectively. Survival rates decreased with the TRI-SCORE in the three treatment groups (all P < .0001). In the low TRI-SCORE category, survival rates were higher in the surgical and transcatheter groups than in the conservative management group (93%, 87%, and 79%, respectively, P = .0002). In the intermediate category, no significant difference between groups was observed overall (80%, 71%, and 71%, respectively, P = .13) but benefit of the intervention became significant when the analysis was restricted to patients with successful correction (80%, 81%, and 71%, respectively, P = .009). In the high TRI-SCORE category, survival was not different to conservative management in the surgical and successful repair group (61% and 68% vs 58%, P = .26 and P = .18 respectively). CONCLUSIONS: Survival progressively decreased with the TRI-SCORE irrespective of treatment modality. Compared to conservative management, an early and successful surgical or transcatheter intervention improved 2-year survival in patients at low and, to a lower extent, intermediate TRI-SCORE, while no benefit was observed in the high TRI-SCORE category.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Resultado do Tratamento , Cateterismo Cardíaco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...