Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
2.
Int J Cardiol ; 140(1): 66-72, 2010 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-19131135

RESUMO

BACKGROUND: Elevations in troponin T (TnT) occur frequently following percutaneous coronary intervention (PCI) and are associated with an adverse prognosis. The Joint ESC/ACC/AHA/WHF Task Force have released a proposal for a universal definition of myocardial infarction (MI), including diagnostic criteria for PCI associated MI. This is based on a TnT cut-point of more than three times the 99th percentile (0.03 ng/ml), which better reflects the precision of the assay. Our study investigated the incidence and predictive factors of a PCI associated MI, using the revised definition. METHODS: 325 patients were studied following PCI with stenting. TnT was collected at both 8 and 18 h following PCI in patients with either stable or unstable angina and normal baseline TnT levels. Comparison was made of both clinical and procedural characteristics of patients with and without a rise in TnT following intervention, using cut points of 0.01 and 0.03 ng/ml. RESULTS: TnT was elevated > or = 0.03 ng/ml in 27% and > or = 0.01 ng/ml in 39% of patients following PCI. Troponin elevation was significantly more likely in those patients who experienced peri-procedural ischemic symptoms or EKG changes, or in whom abciximab was used. The variables associated with a troponin rise showed a greater difference between TnT positive and negative patients when using 0.03 ng/ml compared to 0.01 ng/ml, suggesting that this may be a better definition of PCI-related MI. CONCLUSIONS: Approximately one-quarter of low risk patients experience a procedural MI according to the revised definition. Rises in troponin were significantly associated with peri-procedural ischemic symptoms and EKG changes, and abciximab use, consistent with this level of TnT reflecting true myocardial necrosis.


Assuntos
Angioplastia Coronária com Balão , Infarto do Miocárdio/epidemiologia , Troponina T/sangue , Abciximab , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Anticorpos Monoclonais/uso terapêutico , Eletrocardiografia , Humanos , Fragmentos Fab das Imunoglobulinas/uso terapêutico , Incidência , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Inibidores da Agregação Plaquetária/uso terapêutico , Prognóstico , Estudos Retrospectivos
3.
Ultrasound Med Biol ; 33(1): 67-73, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17189048

RESUMO

Optical coherence tomography (OCT) is an optical analog of mechanical intravascular ultrasound (M-IVUS) with much higher spatial resolution. However, no data exist regarding the nonuniform rotational distortion (NURD) with OCT. The aim of the study was to investigate whether OCT generates less NURD relative to M-IVUS. A coronary artery phantom model was constructed with a rubber ring (3.68 mm in diameter), located at the distal end of the phantom. This model was also composed of eight equally spaced steel wires and an additional marker-wire. Two types of vascular phantoms were used, mild curve (90 degrees ) and acute curve (near 180 degrees ). Subsequent M-IVUS (n = 6) and OCT (n = 6) imaging was performed. Eight angles between eight wires, except the marker-wire, were measured from each image. These angles, measured with M-IVUS and OCT, were compared with those of high-resolution optical photography as a gold standard. The average in angle differences was significantly smaller in OCT compared with M-IVUS in the mild curve model (3.2 +/- 1.0 degrees vs, 6.9 +/- 2.1 degrees , p < 0.01). Compared with the latter model, the average in angle differences was exaggerated in the acute curve model with M-IVUS (9.1 +/- 0.9 degrees vs. 6.9 +/- 2.1 degrees , p < 0.05) but not with OCT (3.5 +/- 0.8 degrees vs. 3.2 +/- 1.0 degrees , p= not significant). OCT generates significantly less NURD compared with M-IVUS, especially in tortuous situation.


Assuntos
Vasos Coronários/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Ultrassonografia de Intervenção/métodos , Artefatos , Cateterismo , Desenho de Equipamento , Humanos , Imagens de Fantasmas , Rotação , Tomografia de Coerência Óptica/instrumentação , Ultrassonografia de Intervenção/instrumentação
4.
Circulation ; 114(1 Suppl): I435-40, 2006 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-16820615

RESUMO

BACKGROUND: The use of saphenous vein grafts (SVG) in coronary artery bypass surgery is established but little is known of SVG remodeling during the first year in vivo. METHODS AND RESULTS: The feasibility of measuring total vessel diameter (lumen plus wall), lumen diameter, and wall thickness by a novel computed tomography (CT) method was established in phantom model tubes (r=0.98 for lumen diameter and r=0.98 for wall thickness) and in an initial clinical study of 14 patients correlating CT and intravascular ultrasound measurements of SVG (r=0.88 for total vessel diameter, r=0.85 for lumen diameter and r=0.89 for wall thickness). In a separate group of 42 patients (aged 66+/-10 years; 36 male, 6 female) undergoing coronary artery bypass grafting, SVG total vessel diameter, lumen diameter, and wall thickness were determined prospectively with multi-slice CT angiography at 1 and 12 months postoperatively. Mean total vessel diameter decreased from 5.95+/-0.83 mm to 5.39+/-0.87 mm, P<0.001 (range, -39% to +8% change). Twenty-six patients (62%) had a decrease of SVG vessel diameter (negative remodeling) >5%. Mean lumen diameter decreased from 3.69+/-0.66 mm to 3.36+/-0.68 mm, P<0.001, (range, -40 to +11% change). Surprisingly, mean wall thickness decreased from 1.14+/-0.27 mm to 1.01+/-0.21 mm (P<0.001; range, -48 to +33% change). CONCLUSIONS: Lumen loss in SVG between postoperative months 1 and 12 is predominantly caused by negative remodeling of the whole vessel rather than to changes in wall thickness. Therapies targeting negative remodeling may be required for optimal maintenance of SVG lumen in the first postoperative year.


Assuntos
Ponte de Artéria Coronária/métodos , Reestenose Coronária/etiologia , Oclusão de Enxerto Vascular/etiologia , Veia Safena/transplante , Antagonistas Adrenérgicos beta/farmacologia , Idoso , Estudos de Coortes , Ponte de Artéria Coronária/estatística & dados numéricos , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/epidemiologia , Reestenose Coronária/patologia , Reestenose Coronária/fisiopatologia , Estudos de Viabilidade , Feminino , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/epidemiologia , Oclusão de Enxerto Vascular/patologia , Oclusão de Enxerto Vascular/fisiopatologia , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Metoprolol/farmacologia , Pessoa de Meia-Idade , Imagens de Fantasmas , Período Pós-Operatório , Veia Safena/diagnóstico por imagem , Veia Safena/patologia , Método Simples-Cego , Tomografia Computadorizada por Raios X , Transplante Heterólogo , Ultrassonografia de Intervenção
6.
J Am Soc Echocardiogr ; 19(3): 347-53, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16500500

RESUMO

BACKGROUND: Acute pulmonary thromboembolism (PTE) can be associated with right ventricular (RV) dysfunction. The relative importance of individual echocardiographic parameters, including those suggesting interdependence between right and left heart chambers, in predicting thromboembolic burden in elderly patients with acute PTE is unknown. METHODS: We retrospectively studied the transthoracic echocardiograms of 63 elderly patients (age 71 +/- 16 years) with acute PTE, and assessed which individual echocardiographic parameters identified more than 30% pulmonary artery obstruction on the basis of quantitative ventilation/perfusion pulmonary scintigraphy. RESULTS: RV hypokinesis (visual grade 0-3, P = .02), and the quantitative parameters RV end-systolic area (P = .005) and RV ejection area (P = .01) were associated with more extensive pulmonary artery obstruction. Although right atrial end-systolic area and RV end-diastolic area did not correlate with extent of PTE, the ratio of RV:left ventricular end-diastolic area (P = .003), and ratio of right:left atrial end-systolic area (P = .004), were strongly associated with the extent of pulmonary artery obstruction. These transthoracic echocardiographic parameters were independent of clinical variables such as prior chronic lung disease, congestive cardiac failure, or prior PTE. CONCLUSION: RV systolic dysfunction, RV end-systolic dilatation, right:left atrial end-systolic area ratio, and RV:left ventricular end-diastolic area ratio correlate with extent of PTE in the elderly.


Assuntos
Ecocardiografia/métodos , Átrios do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Embolia Pulmonar/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Embolia Pulmonar/complicações , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Estatística como Assunto , Disfunção Ventricular Direita/etiologia
7.
Radiology ; 235(2): 415-22, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15858083

RESUMO

PURPOSE: To investigate prospectively the relative accuracy of computed tomographic (CT) angiography, calcium scoring (CS), and both methods combined in demonstrating coronary artery stenoses by using conventional angiography as the reference standard. MATERIALS AND METHODS: The study was approved by the institutional review board Human Research Ethics Committee, and all patients completed written informed consent. Fifty patients (40 men, 10 women) aged 62 years +/- 11 (+/- standard deviation) who were suspected of having coronary artery disease underwent both conventional coronary angiography and multisection coronary CT angiography with CS. Sensitivity and specificity of CS, CT angiography, and both methods combined in demonstrating luminal stenosis greater than or equal to 50% were determined for each arterial segment, coronary vessel, and patient. Receiver operating characteristic (ROC) curves were generated for CS prediction of significant stenosis, and the Mann-Whitney U test was used for comparison of CS between groups. RESULTS: When used with segment-specific electrocardiographic phase reconstructions, CT angiography demonstrated stenosed segments with 79% sensitivity and 95% specificity. Mean calcium score was greater in segments, vessels, and patients with stenoses than in segments, vessels, and patients without stenoses (P < .001 for all); nine (16%) of 56 stenosed segments, however, had a calcium score of 0. The patient calcium score correlated strongly with the number of stenosed arteries (Spearman rho = 0.75, P < .001). CS was more accurate in demonstrating stenosis in patients than in segments (areas under ROC curve were 0.88 and 0.74, respectively). CT angiography, however, was more accurate than CS in demonstrating stenosis in patients, vessels, and segments. The sensitivity and specificity of CS varied according to the threshold used, but when the calcium score cutoff (ie, >150) matched the specificity of CT angiography (95%), the sensitivity of CS in demonstrating stenosed segments was 29% (compared with 79% for CT angiography). Combining CT angiography with CS (at threshold of 400) improved the sensitivity of CT angiography (from 93% to 100%) in demonstrating significant coronary disease in patients, without a loss of specificity (85%); this finding, however, was not statistically significant. CONCLUSION: CT angiography is more accurate than CS in demonstrating coronary stenoses. A patient calcium score of greater than or equal to 400, however, can be used to potentially identify patients with significant coronary stenoses not detected at CT angiography.


Assuntos
Calcinose/diagnóstico por imagem , Cálcio/análise , Angiografia Coronária/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Tomografia Computadorizada Espiral/estatística & dados numéricos , Adulto , Idoso , Algoritmos , Interpretação Estatística de Dados , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Valores de Referência , Risco , Sensibilidade e Especificidade
8.
Am J Cardiol ; 94(9): 1214-6, 2004 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-15518629

RESUMO

We present a series of 9 adults in 2 families with isolated noncompaction of the ventricular myocardium involving the left ventricular apex. Three of these patients had been previously misdiagnosed as having dilated cardiomyopathy, apical hypertrophic cardiomyopathy, or apical mural thrombus. Phenotypic variation was observed with gradation of severity of noncompaction and left ventricular systolic dysfunction between first-degree relatives.


Assuntos
Miocárdio/patologia , Adolescente , Adulto , Idoso , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/genética , Cardiomiopatia Dilatada/fisiopatologia , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/genética , Cardiomiopatia Hipertrófica/fisiopatologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/genética , Doença da Artéria Coronariana/fisiopatologia , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/genética , Trombose Coronária/fisiopatologia , Diagnóstico Diferencial , Ecocardiografia Doppler em Cores , Eletrocardiografia Ambulatorial , Saúde da Família , Feminino , Predisposição Genética para Doença/genética , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/genética , Hipertrofia Ventricular Esquerda/fisiopatologia , Masculino , Pessoa de Meia-Idade , Linhagem , Volume Sistólico/genética , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...