Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Am J Case Rep ; 21: e926781, 2020 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-32952147

RESUMO

BACKGROUND Coronavirus disease 2019 (COVID-19) is caused by a novel coronavirus, SARS-CoV-2, and is associated with severe respiratory disease. There are extensive publications on the chest computed tomography (CT) findings of COVID-19 pneumonia, with ground-glass opacities (GGO) and mixed GGO and consolidation being the most common findings. Those with interstitial thickening manifesting as reticular opacities typically show superimposed ground-glass opacities, giving a crazy-paving pattern. CASE REPORT We report the case of a 77-year-old man with a background of asthma-chronic obstructive pulmonary disease (COPD) overlap syndrome (ACOS) who presented with progressive cough and shortness of breath for 2 days. He was in close contact with a confirmed COVID-19 case. Reverse-transcription polymerase chain reaction analysis of a nasopharyngeal swab was positive for SARS-CoV-2. The initial chest radiograph was negative for lung consolidation and ground-glass opacities. During admission, he had worsening shortness of breath with desaturation, prompting a chest CT examination, which was performed on day 14 of illness. The chest CT revealed an atypical finding of predominant focal subpleural interstitial thickening in the right lower lobe. He was provided supportive treatment along with steroid and antibiotics. He recovered well and subsequently tested negative for 2 consecutive swabs. He was discharged after 34 days. CONCLUSIONS Interstitial thickening or reticular pattern on CT has been described in COVID-19 pneumonia, but largely in association with ground-glass opacity or consolidation. This case demonstrates an atypical predominance of interstitial thickening on chest CT in COVID-19 pneumonia on day 14 of illness, which is the expected time of greatest severity of the disease.


Assuntos
Infecções por Coronavirus/diagnóstico , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Pneumonia Viral/diagnóstico , Intensificação de Imagem Radiográfica , Síndrome Respiratória Aguda Grave/diagnóstico por imagem , Corticosteroides/administração & dosagem , Idoso , Antibacterianos/administração & dosagem , COVID-19 , Teste para COVID-19 , Técnicas de Laboratório Clínico , Meios de Contraste , Infecções por Coronavirus/complicações , Tosse/diagnóstico , Tosse/etiologia , Progressão da Doença , Dispneia/diagnóstico , Dispneia/etiologia , Seguimentos , Humanos , Unidades de Terapia Intensiva , Tempo de Internação , Doenças Pulmonares Intersticiais/complicações , Doenças Pulmonares Intersticiais/terapia , Masculino , Pandemias , Pneumonia Viral/complicações , Pneumonia Viral/diagnóstico por imagem , Medição de Risco , Síndrome Respiratória Aguda Grave/virologia , Resultado do Tratamento
3.
Artigo em Inglês | MEDLINE | ID: mdl-18051164

RESUMO

Quantitative ultrasound tissue characterization based on integrated backscatter (IB) has shown great potential in detecting myocardial ischemia. The magnitude of the cyclic variation in IB (CVIB) has recently been considered as one of the most promising parameters in assessing regional myocardial contractile performance. Our laboratory previously developed a novel ultrasonic fusion imaging method based on the CVIB. However, the major problem for clinical applications of this technique and other existing analytical methods based on IB is that the myocardial tissue can't be traced effectively without the cardiologist's intervention. In order to solve this problem, this paper presents a snake-based tracking algorithm to trace myocardial tissue automatically. A mathematical method is also introduced to extend the application of the snake model for detecting non-closed contours. The system developed in our previous research was redesigned to synchronize the radio frequency signal, the electrocardiographic signal, and the video signal, which allows verification of the system. Our results suggest that the system using the auto-tracking method increases the accuracy of detecting myocardial ischemia.


Assuntos
Algoritmos , Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Função Ventricular , Animais , Inteligência Artificial , Cães , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/métodos , Contração Miocárdica/fisiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Int J Biomed Imaging ; 2007: 84724, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18354740

RESUMO

Conjugate gradient method is verified to be efficient for nonlinear optimization problems of large-dimension data. In this paper, a penalized linear and nonlinear combined conjugate gradient method for the reconstruction of fluorescence molecular tomography (FMT) is presented. The algorithm combines the linear conjugate gradient method and the nonlinear conjugate gradient method together based on a restart strategy, in order to take advantage of the two kinds of conjugate gradient methods and compensate for the disadvantages. A quadratic penalty method is adopted to gain a nonnegative constraint and reduce the illposedness of the problem. Simulation studies show that the presented algorithm is accurate, stable, and fast. It has a better performance than the conventional conjugate gradient-based reconstruction algorithms. It offers an effective approach to reconstruct fluorochrome information for FMT.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA