Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dentomaxillofac Radiol ; 53(1): 74-85, 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38214941

RESUMO

MRI is a noninvasive, ionizing radiation-free imaging modality that has become an indispensable medical diagnostic method. The literature suggests MRI as a potential diagnostic modality in dentomaxillofacial radiology. However, current MRI equipment is designed for medical imaging (eg, brain and body imaging), with general-purpose use in radiology. Hence, it appears expensive for dentists to purchase and maintain, besides being complex to operate. In recent years, MRI has entered some areas of dentistry and has reached a point in which it can be provided following a tailored approach. This technical report introduces a dental-dedicated MRI (ddMRI) system, describing how MRI can be adapted to fit dentomaxillofacial radiology through the appropriate choice of field strength, dental radiofrequency surface coil, and pulse sequences. Also, this technical report illustrates the possible application and feasibility of the suggested ddMRI system in some relevant diagnostic tasks in dentistry. Based on the presented cases, it is fair to consider the suggested ddMRI system as a feasible approach to introducing MRI to dentists and dentomaxillofacial radiology specialists. Further studies are needed to clarify the diagnostic accuracy of ddMRI considering the various diagnostic tasks relevant to the practice of dentistry.


Assuntos
Imageamento por Ressonância Magnética , Radiologia , Humanos , Estudos de Viabilidade , Imageamento por Ressonância Magnética/métodos , Radiografia
2.
Arthritis Rheumatol ; 66(12): 3283-8, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25185889

RESUMO

Objective: To investigate the factors associated with cartilage proteoglycan content in patients with rheumatoid arthritis (RA) Methods: 32 RA patients received high-field 3 Tesla Gadolinium-Enhanced MRI of Cartilage (dGEMRIC) for determining cartilage proteoglycan content. Measurements were performed in three individual cartilage regions (medial, central, lateral) of the metacarpophalangeal joints 2 and 3. dGEMRIC values were then related to disease duration, disease activity, anti-citrullinated protein antibody (ACPA) status, rheumatoid factor status and C-reactive protein level. Results: dGEMRIC values were not significantly different between the MCP2 and MCP3 joint. Inter-class correlations were high (>0.92) for all three (medial, central and lateral) cartilage compartments. dGEMRIC values were significantly lower in RA patients with longer disease duration (≥3 years) and those with ACPA positivity than those with a short disease duration (<3 years)(p=0.034) or negative ACPA (p=0.0002), respectively. In contrast, no association between cartilage proteoglycan content and disease activity, C-reactive protein level and rheumatoid factor status was found. Conclusion: Decreased cartilage proteoglycan content in RA patients is associated with disease duration and ACPA positivity but not with the actual disease activity, CRP level or rheumatoid factor status. These data suggest that the cumulative burden of inflammation as well as ACPA are the determinants for cartilage damage in RA.


Assuntos
Artrite Reumatoide/imunologia , Autoanticorpos/análise , Cartilagem/química , Articulação Metacarpofalângica/imunologia , Proteoglicanas/análise , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Adulto Jovem
3.
Ann Rheum Dis ; 73(6): 1101-6, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23625980

RESUMO

OBJECTIVES: To investigate the relation between anatomic changes of the synovium, the bone, the bone marrow and the cartilage to biochemical properties of the cartilage in patients with rheumatoid arthritis (RA). METHODS: 33 patients with RA received 3-T MRI scans of the metacarpophalangeal joints. Two independent methods, (A) the delayed gadolinium enhanced MRI of the cartilage (dGEMRIC, T2-mapping), which was used to assess the biochemical properties of the cartilage; (B) synovitis, osteitis and bone erosions were quantified according to the RA MRI scoring (RAMRIS) method and cartilage thickness (CT), interbone joint space (IBJS, distance between proximal and distal bone surface) and intercartilage joint space (ICJS, distance between proximal and distal cartilage surface) were measured. RESULTS: Biochemical changes of the cartilage, corresponding to low dGEMRIC and high T2 values, were more likely to be seen in joints with decreased IBJS and ICJS as well as decreased CT. For instance, dGEMRIC was directly correlated to the IBJS (p=0.001) and ICJS (p=0.001), whereas T2 mapping was inversely correlated to IBJS and ICJS (both p=0.017). Moreover, the degree of osteitis, and to some extent synovitis, was correlated to biochemical cartilage changes as measured by dGEMRIC (p=0.003) or the T2 mapping (p=0.013). By contrast, bone erosions did not correlate to the degree of biochemical cartilage changes. DISCUSSION: These data support the concept that synovitis and osteitis may be two main triggers for cartilage damage. Thus, the actual inflammatory state of a joint, but not so much the degree of bone erosion, appears to influence cartilage properties in RA.


Assuntos
Artrite Reumatoide/metabolismo , Cartilagem Articular/metabolismo , Articulação Metacarpofalângica/metabolismo , Osteíte/metabolismo , Proteoglicanas/metabolismo , Sinovite/metabolismo , Adulto , Artrite Reumatoide/patologia , Reabsorção Óssea , Cartilagem Articular/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Articulação Metacarpofalângica/patologia , Pessoa de Meia-Idade , Osteíte/patologia , Membrana Sinovial/metabolismo , Membrana Sinovial/patologia , Sinovite/patologia
4.
Radiology ; 260(1): 257-64, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21460030

RESUMO

PURPOSE: To compare a glycosaminoglycan chemical exchange saturation transfer (gagCEST) imaging method, which enables sampling of the water signal as a function of the presaturation offset (z-spectrum) at 13 points in clinically feasible imaging times, with sodium 23 ((23)Na) magnetic resonance (MR) imaging in patients after cartilage repair surgery (matrix-associated autologous chondrocyte transplantation and microfracture therapy). MATERIALS AND METHODS: One female patient (67.3 years), and 11 male patients (median age, 28.8 years; interquartile range [IQR], 24.6-32.3 years) were examined with a 7-T whole-body system, with approval of the local ethics committee after written informed consent was obtained. A modified three-dimensional gradient-echo sequence and a 28-channel knee coil were used for gagCEST imaging. (23)Na imaging was performed with a circularly polarized knee coil by using a modified gradient-echo sequence. Statistical analysis of differences and Spearman correlation were applied. RESULTS: The median of asymmetries in gagCEST z-spectra summed over all offsets from 0 to 1.3 ppm was 7.99% (IQR, 6.33%-8.79%) in native cartilage and 5.13% (IQR, 2.64%-6.34%) in repair tissue. A strong correlation (r = 0.701; 95% confidence interval: 0.21, 0.91) was found between ratios of signal intensity from native cartilage to signal intensity from repair tissue obtained with gagCEST or (23)Na imaging. The median of dimensionless ratios between native cartilage and repair tissue was 1.28 (IQR, 1.20-1.58) for gagCEST and 1.26 (IQR, 1.21-1.48) for (23)Na MR imaging. CONCLUSION: The high correlation between the introduced gagCEST method and (23)Na imaging implies that gagCEST is a potentially useful biomarker for glycosaminoglycans.


Assuntos
Cartilagem Articular/metabolismo , Cartilagem Articular/patologia , Glicosaminoglicanos/metabolismo , Imageamento por Ressonância Magnética/métodos , Adulto , Artroplastia Subcondral , Meios de Contraste/farmacocinética , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Isótopos de Sódio/farmacocinética , Adulto Jovem
5.
J Magn Reson Imaging ; 33(1): 180-8, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21182137

RESUMO

PURPOSE: To evaluate a new isotropic 3D proton-density, turbo-spin-echo sequence with variable flip-angle distribution (PD-SPACE) sequence compared to an isotropic 3D true-fast-imaging with steady-state-precession (True-FISP) sequence and 2D standard MR sequences with regard to the new 3D magnetic resonance observation of cartilage repair tissue (MOCART) score. MATERIALS AND METHODS: Sixty consecutive MR scans on 37 patients (age: 32.8 ± 7.9 years) after matrix-associated autologous chondrocyte transplantation (MACT) of the knee were prospectively included. The 3D MOCART score was assessed using the standard 2D sequences and the multiplanar-reconstruction (MPR) of both isotropic sequences. Statistical, Bonferroni-corrected correlation as well as subjective quality analysis were performed. RESULTS: The correlation of the different sequences was significant for the variables defect fill, cartilage interface, bone interface, surface, subchondral lamina, chondral osteophytes, and effusion (Pearson coefficients 0.514-0.865). Especially between the standard sequences and the 3D True-FISP sequence, the variables structure, signal intensity, subchondral bone, and bone marrow edema revealed lower, not significant, correlation values (0.242-0.383). Subjective quality was good for all sequences (P ≥ 0.05). Artifacts were most often visible on the 3D True-FISP sequence (P < 0.05). CONCLUSION: Different isotropic sequences can be used for the 3D evaluation of cartilage repair with the benefits of isotropic 3D MRI, MPR, and a significantly reduced scan time, where the 3D PD-SPACE sequence reveals the best results.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Meniscos Tibiais/patologia , Lesões do Menisco Tibial , Anisotropia , Condrócitos/transplante , Feminino , Humanos , Traumatismos do Joelho/patologia , Traumatismos do Joelho/cirurgia , Masculino , Meniscos Tibiais/cirurgia , Pessoa de Meia-Idade , Prótons , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
6.
Biotechnol Prog ; 19(5): 1562-8, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14524720

RESUMO

The in vitro assembly of neuronal networks with control over cell position and connectivity is a fascinating approach not only for topics in basic neuroscience research but also in diverse applications such as biosensors and tissue engineering. We grew rat embryonic cortical neurons on patterned substrates created by microcontact printing. Polystyrene was used as a cell repellent background, onto which a grid pattern of physiological proteins was applied. We printed laminin and a mixture of extracellular matrix proteins and additionally both systems mixed with polylysine. Attachment of cells to the pattern with high fidelity as well as the formation of chemical synapses between neighboring cells on the pattern could be observed in all four cases, but cell attachment was strongly increased on samples containing polylysine. Neurons grown on patterned substrates had a membrane capacity smaller than that of neurons on homogeneously coated controls, which we attributed to the geometrical restrictions, but did not differ either in resting membrane potential or in the quality of synapses they formed. We therefore believe that the cells attach and differentiate normally on the pattern and form functional, mature synapses following the predefined geometry.


Assuntos
Potenciais de Ação/fisiologia , Técnicas de Cultura de Células/instrumentação , Técnicas de Cultura de Células/métodos , Membranas Artificiais , Rede Nervosa/citologia , Rede Nervosa/crescimento & desenvolvimento , Neurônios/citologia , Neurônios/fisiologia , Adesão Celular/fisiologia , Células Cultivadas , Manufaturas , Poliestirenos , Transmissão Sináptica/fisiologia
7.
Biosens Bioelectron ; 17(1-2): 87-93, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11742739

RESUMO

A microfluidic device in polydimethylsiloxane (PDMS) consisting of an eight lines micro-injection array integrated in a base flow channel has been realized. The device is assembled from multiple PDMS parts, which have been moulded using notably micromachined masters in SU-8 photoresist. In contact with a planar substrate, up to eight independent laminar flow lines with cross-sections of 100 x 200 microm(2) can be generated. Dedicated for the application of pharmaceutical compounds to electrogenic cells in vitro, this device was tested with a neuronal cell line, Mz1-cells. These were cultured on lines of laminin deposited onto polystyrene substrates by microcontact printing. We were able to inject into this culture multiple lines of coloured PBS in parallel to the orientation of cellular growth. No mixing between the individual flow lines did occur.


Assuntos
Técnicas de Cultura de Células/instrumentação , Neurônios/citologia , Animais , Técnicas de Cultura de Células/métodos , Divisão Celular , Dimetilpolisiloxanos , Camundongos , Microinjeções , Neurônios/efeitos dos fármacos , Silicones
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...