Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Prosthodont ; 10(6): 520-30, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9495172

RESUMO

This investigation evaluated the shear rebond strength of Rexillium III to enamel using various resin composite luting systems (Panavia, Imperva Dual, ABC Enhanced, C&B Metabond, Optibond, and Comspan). Cast Rexillium III cylinders (3.9 x 6.0 mm) were bonded to human molar buccal enamel surfaces (n = 8) with each cement type after etching with 37% phosphoric acid for 30 seconds. Bonded specimens were stored in distilled water for 7 days at 37 degrees C +/- 2 degrees C and thermocycled (1,500 cycles) in 5 degrees C and 55 degrees C water baths (1 minute dwell time). Specimens were randomly tested in shear mode on an Instron Testing Machine at a crosshead speed of 0.5 mm per minute. Debonded specimens were then rebonded after appropriate metal conditioning and re-etching the enamel surface for 30 seconds. Analysis of variance (P < 0.001) and the Ryan-Einot-Gabriel-Welsh multiple range test showed significant differences between several of the resin cements (P < 0.05). Panavia exhibited significantly higher shear rebond strength than any of the other cements tested. Only Imperva Dual exhibited a significantly lower shear rebond strength compared to its initial shear bond strength.


Assuntos
Ligas de Cromo/química , Ligas Dentárias/química , Colagem Dentária , Esmalte Dentário/efeitos dos fármacos , Cimentos de Resina/química , Condicionamento Ácido do Dente , Análise de Variância , Esmalte Dentário/ultraestrutura , Humanos , Técnicas In Vitro , Teste de Materiais/métodos , Teste de Materiais/estatística & dados numéricos , Microscopia Eletrônica de Varredura , Dente Molar , Distribuição Aleatória , Propriedades de Superfície , Resistência à Tração
2.
Int J Prosthodont ; 9(6): 555-62, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-9171494

RESUMO

This study evaluated the shear bond strength of Rexillium III (Jeneric Pentron, Wallingford, CT) to enamel using various resin composite luting systems. Cast alloy cylinders (3.9 mm X 6.0 mm) were bonded with each cement to human molar buccal enamel surfaces (n = 8). The enamel was etched using a 35% phosphoric acid solution for 30 seconds. Bonded specimens were stored in distilled water for 7 days at 37 degrees C and thermocycled (1,500 cycles) in 5 degrees C and 55 degrees C water baths (1-minute dwell time). Specimens were randomly tested in shear using a crosshead speed of 0.5 mm per minute. Use of a one-way analysis of variance (P < .001) and Ryan-Einot-Gabriel-Welsh multiple range test showed significant differences between several of the resin cements. Panavia exhibited a significantly higher shear bond strength than any of the other cements tested.


Assuntos
Ligas de Cromo , Colagem Dentária , Cimentos de Resina , Análise de Variância , Bis-Fenol A-Glicidil Metacrilato , Compostos de Boro , Esmalte Dentário/ultraestrutura , Combinação de Medicamentos , Humanos , Teste de Materiais , Metacrilatos , Metilmetacrilatos , Microscopia Eletrônica de Varredura , Fosfatos , Resistência à Tração , Toluidinas
3.
J Prosthodont ; 5(2): 105-10, 1996 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9028213

RESUMO

PURPOSE: The effects of oblique compressive forces were evaluated for extracted teeth restored with posts of solid and internally threaded designs. MATERIALS AND METHODS: A group of 25 roots was restored with crowns supported by Para-post dowels and pin-retained composite resin cores, and a second group was restored with gold copings cast to internally threaded stainless steel-post prototypes. Samples were then embedded in epoxy resin and loaded at 45 degrees until failure. Failure force and type were statistically analyzed to determine statistical difference (P < .05) between groups. RESULTS: No statistical difference was shown between groups for either fracture force or type. CONCLUSIONS: The internally threaded post system resisted oblique loading forces similarly to a solid post system.


Assuntos
Análise do Estresse Dentário , Técnica para Retentor Intrarradicular/instrumentação , Análise de Variância , Distribuição de Qui-Quadrado , Resinas Compostas , Força Compressiva , Coroas , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Teste de Materiais , Distribuição Aleatória , Aço Inoxidável , Dente não Vital
4.
Artigo em Inglês | MEDLINE | ID: mdl-7552888

RESUMO

Recent developments in technology, direct placement restorative materials, and cavity preparation design have renewed interest in kinetic cavity preparation, a term to describe the use of air-abrasion for removal of tooth structure. This study compared the pulpal response of 120 teeth in mixed-breed dogs treated with four kinetic cavity preparation combinations of pressure (80 psi and 160 psi) and aluminum oxide particle sizes (27 microns and 50 microns) to those treated with high-speed rotary burs. Class V buccal preparations were made and restored with an interim material. Teeth were collected 72 hours after surgery, decalcified, sectioned, stained with hematoxylin and eosin, and blindly evaluated by two examiners at the minimal dentin thickness. Samples were graded for extent of displacement, disruption, inflammation, and necrosis of pulpal structures. Differences between groups were analyzed with the use of Bonferroni-adjusted multiple Mann-Whitney-Wilcoxon tests with p < 0.05 being significant. Higher pressures and smaller particles yielded significantly fewer pulpal effects than the high-speed treated teeth whereas lower pressures and larger particles were not significantly different for most effects evaluated. No adverse soft tissue effects were noted when kinetic cavity preparation was directed at attached gingiva.


Assuntos
Preparo da Cavidade Dentária/métodos , Polpa Dentária , Pressão do Ar , Óxido de Alumínio , Animais , Preparo da Cavidade Dentária/efeitos adversos , Preparo da Cavidade Dentária/instrumentação , Técnica Odontológica de Alta Rotação/efeitos adversos , Polpa Dentária/lesões , Polpa Dentária/ultraestrutura , Cães , Tamanho da Partícula , Estatísticas não Paramétricas , Raiz Dentária
5.
Quintessence Int ; 26(2): 139-44, 1995 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-7568724

RESUMO

Recent developments in technology and restorative materials have renewed interest in air abrasion as a means of tooth preparation. The technique, also called kinetic cavity preparation, uses kinetic energy to remove tooth structure. The purpose of this investigation was to use scanning electron microscopy to compare the effects of this technique to those of high-speed burs on extracted human teeth. Class V buccal preparations were made on five teeth with a No. 34 carbide bur used at 400,000 rpm and on 23 teeth with kinetic cavity preparation using differing combinations of aluminum oxide particle sizes and delivery pressures. Features of the specimens prepared at high speed included sharp line angles, chipping of the cavo-surface margin, and striated internal surfaces. Kinetic cavity preparations had rounded cavo-surface margins and internal line angles. The surfaces were microscopically rough and the dentinal tubules were occluded. There was little difference in appearance between specimens treated with various combinations of particle sizes and delivery pressures.


Assuntos
Preparo da Cavidade Dentária/métodos , Esmalte Dentário/ultraestrutura , Técnica Odontológica de Alta Rotação , Dentina/ultraestrutura , Pressão do Ar , Óxido de Alumínio , Humanos , Microscopia Eletrônica de Varredura , Propriedades de Superfície
6.
J Prosthet Dent ; 69(3): 258-61, 1993 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8445554

RESUMO

Internally threaded, stainless steel posts 10 mm in length and 1.82 mm in diameter or stainless-steel Para-Post dowels 1.7 mm in diameter were cemented in extracted human teeth with zinc phosphate cement. Titanium alloy screws 1.5 mm in diameter were placed in the internally threaded posts and tensile force was applied to the screws or Para-Post dowels until dislodgment of the post or fracture. The retention of the Para-Post system was significantly greater than the experimental posts. Although all screws exhibited deformation, there was no breakage or distortion of the internally threaded posts or Para-Post dowels. Retention for both systems exceeded reported forces generated in humans.


Assuntos
Retenção em Prótese Dentária/métodos , Técnica para Retentor Intrarradicular/instrumentação , Análise de Variância , Força de Mordida , Análise do Estresse Dentário , Humanos , Técnica para Retentor Intrarradicular/normas , Resistência à Tração , Fraturas dos Dentes
7.
J Oral Rehabil ; 17(5): 403-10, 1990 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-2231158

RESUMO

The objective of this study was to determine the forces on dental prosthetic magnet keepers, with a view to assessing the potential for patient injury during magnetic resonance imaging (MRI). Four pre-formed keepers and one castable keeper alloy were tested. Magnetizations and high field susceptibilities were determined for each of the five specimens using data from a vibrating sample magnetometer. The magnetic field intensity with respect to distance from the main magnet coil was obtained from the manufacturer (1-5 tesla General Electric Signa Imaging System). A plot of force versus distance from the main coil and the maximum force at the magnet portal was determined for each specimen. The maximum forces ranged from 0.12-0.24 N for the pre-formed keepers and 3.67 MNm-3 for the castable alloy. It was concluded that the risk of patient injury by displacement is minimal, if the keepers are properly attached to supporting structures.


Assuntos
Planejamento de Dentadura , Retenção de Dentadura , Imageamento por Ressonância Magnética , Magnetismo , Ligas Dentárias , Campos Eletromagnéticos , Humanos , Modelos Teóricos , Estresse Mecânico , Propriedades de Superfície
8.
J Prosthet Dent ; 62(3): 344-8, 1989 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-2681704

RESUMO

Eight types of prosthetic magnet keepers were imaged in a water phantom and a living human subject by a 1.5 T magnetic resonance device. Image artifacts were present for all eight samples and ranged from 160 mm to greater than 280 mm in diameter. These artifacts obliterate vital craniocervical areas making their examination by magnetic resonance impossible. Patients with magnetic keepers requiring comprehensive magnetic resonance imaging of the head and neck region must have them removed.


Assuntos
Retenção de Dentadura , Dentaduras , Imageamento por Ressonância Magnética , Magnetismo , Planejamento de Dentadura , Humanos , Aumento da Imagem , Modelos Estruturais , Água
13.
J Prosthet Dent ; 54(3): 439-42, 1985 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-3906098

RESUMO

This article described laboratory and chairside techniques for making a porcelain-bonded-to-metal occlusal overlay repositioning splint and suggests how both dental laboratory technician and dentist can anticipate and overcome some problems commonly encountered during fabrication and seating. A ceramometal occlusal overlay and repositioning splint is often the splint of choice for patients who must wear one at all times during prolonged occlusal splint therapy. Unlike the commonly used acrylic resin splints, the ceramometal splint is durable, provides good esthetics and anatomic functional tooth form, and can be worn at all times including meals.


Assuntos
Oclusão Dentária , Revestimento de Dentadura , Contenções , Porcelana Dentária , Planejamento de Dentadura , Humanos , Mandíbula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...