Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 12(24)2023 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-38137666

RESUMO

In view of the increasing age of cardiac surgery patients, questions arise about the expected postoperative quality of life and the hoped-for prolonged life expectancy. Little is known so far about how these, respectively, are weighted by the patients concerned. This study aims to obtain information on the patients' preferences. Between 2015 and 2017, data were analyzed from 1349 consecutive patients undergoing cardiac surgery at seven heart centers in Germany. Baseline data regarding the patient's situation as well as a questionnaire regarding quality of life versus lifespan were taken preoperatively. Patients were divided by age into four groups: below 60, 60-70, 70-80, and above 80 years. As a result, when asked to decide between quality of life and length of life, about 60% of the male patients opted for quality of life, independent of their age. On the other hand, female patients' preference for quality of life increased significantly with age, from 51% in the group below sixty to 76% in the group above eighty years. This finding suggests that female patients adapt their preferences with age, whereas male patients do not. This should impact further the treatment decisions of elderly patients in cardiac surgery within a shared decision-making process.

2.
J Clin Med ; 12(8)2023 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-37109346

RESUMO

BACKGROUND: Frailty is gaining importance in cardiothoracic surgery and is a risk factor for adverse outcomes and mortality. Various frailty scores have since been developed, but there is no consensus which to use for cardiac surgery. METHODS: In an all-comer prospective study of patients presenting for cardiac surgery, we assessed frailty and analyzed complication rates in hospital and 1-year mortality, as well as laboratory markers before and after surgery. RESULTS: 246 included patients were analyzed. A total of 16 patients (6.5%) were frail, and 130 patients (52.85%) were pre-frail, summarized in the frail group (FRAIL) and compared to the non-frail patients (NON-FRAIL). The mean age was 66.5 ± 9.05 years, 21.14% female. The in-hospital mortality rate was 4.88% and the 1-year mortality rate was 6.1%. FRAIL patients stayed longer in hospital (FRAIL 15.53 ± 8.5 days vs. NON-FRAIL 13.71 ± 8.94 days, p = 0.004) and in intensive/intermediate care units (ITS/IMC) (FRAIL 5.4 ± 4.33 days vs. NON-FRAIL 4.86 ± 4.78 days, p = 0.014). The 6 min walk (6 MW) (317.92 ± 94.17 m vs. 387.08 ± 93.43 m, p = 0.006), mini mental status (MMS) (25.72 ± 4.36 vs. 27.71 ± 1.9, p = 0.048) and clinical frail scale (3.65 ± 1.32 vs. 2.82 ± 0.86, p = 0.005) scores differed between patients who died within the first year after surgery compared to those who survived this period. In-hospital stay correlated with timed up-and-go (TUG) (TAU: 0.094, p = 0.037), Barthel index (TAU-0.114, p = 0.032), hand grip strength (TAU-0.173, p < 0.001), and EuroSCORE II (TAU 0.119, p = 0.008). ICU/IMC stay duration correlated with TUG (TAU 0.186, p < 0.001), 6 MW (TAU-0.149, p = 0.002), and hand grip strength (TAU-0.22, p < 0.001). FRAIL patients had post-operatively altered levels of plasma-redox-biomarkers and fat-soluble micronutrients. CONCLUSIONS: frailty parameters with the highest predictive value as well as ease of use could be added to the EuroSCORE.

3.
Interact Cardiovasc Thorac Surg ; 31(4): 446-453, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32810214

RESUMO

OBJECTIVES: To increase the safety of aortic valve replacement, we developed the 'Caput medusae' method, where the prosthesis is prefixed with circumferential tourniquets prior to knot tying. We assumed that an even distribution of forces may help reduce tissue damage. To confirm this theoretically, we compared forces between knots and tourniquets. METHODS: The experimental set-up included a device with movable acrylic plates, a mounted valve and a set of sutures. Traction forces were measured with a luggage scale. Two different tourniquets were compared individually and as bundles of 15. Force-path curves were generated. Knotting and tourniquet forces of 18 staff surgeons were then compared. Both modalities were measured 10 times on 2 days, resulting in 40 observations per surgeon, or 360 observations per modality. RESULTS: Polyvinyl chloride tourniquets were stiffer than silicone, expressed by a 1.5- to 1.7-fold higher regression-line slope. Fifteen simultaneous tubes produced force increments 7.9-8.9 times higher than their single counterparts. Overall knotting force was 13.64 ± 5.76 vs tourniquet 1.08 ± 0.48 N. Male surgeons' knotting forces were higher compared to female staff (14.76 ± 6.01 vs 10.73 ± 3.74 N; P < 0.001) while tourniquet forces did not differ (1.09 ± 0.47 vs 1.05 ± 0.49 N; P = 0.459). Dedicated valve surgeons (n = 10) tightened the tourniquets more strongly than inexperienced surgeons (1.20 ± 0.52 vs 0.94 ± 0.37 N; P < 0.001); knotting was similar. Multivariable analysis confirmed only valve experience as a predictor of tourniquet strength (experienced surgeons exerted higher force). CONCLUSIONS: Tourniquets exert less force on the tissue than knots. When distributed over the circumference, they can reduce local tension and avoid potential paravalvular leakage. Complete or partial use of tourniquets may thus be an additional option to enhance surgical safety.


Assuntos
Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Cirurgiões/estatística & dados numéricos , Técnicas de Sutura/instrumentação , Suturas , Torniquetes , Humanos , Desenho de Prótese
4.
Thorac Cardiovasc Surg ; 68(7): 557-566, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-30669172

RESUMO

BACKGROUND: Conventional stented valves (CV) remain gold standard for aortic valve disease. Bovine prostheses have been improved and rapid deployment valves (RDV) have arrived in the recent decade. We compare clinical and hemodynamic short-term outcome of six bovine valves. METHODS: We retrospectively evaluated 829 consecutive patients (all-comers) receiving bovine aortic valve replacement (AVR). Four CV from different manufacturers (Mitroflow, Crown, Perimount, Trifecta) and two RDV (Perceval, Intuity) were compared in terms of pre-, intra-, and postprocedural data. A risk model for mortality was created. RESULTS: All valves reduced gradients. From 23 mm, all CV showed acceptable gradients. Twenty-one millimeter Mitroflow/Perceval and 19 mm Crown showed above-average gradients. As baseline data differed, we performed propensity matching between aggregated isolated CV and RDV groups. Cardiopulmonary bypass (CPB), clamp, and surgery times were shorter with RDV (87.4 ± 34.0 min vs 111.0 ± 34.2, 54.3 ± 21.1 vs 74.9 ± 20.4, 155.2 ± 42.9 vs 178.0 ± 46.8, p < 0.001). New pacemaker rate (10.1 vs 1.3%, p = 0.016) and the tendency toward neurologic events (8.9 vs 2.5%, p = 0.086) were higher using RDV, induced mainly by the Perceval. Early mortality was equal (2.5 vs 1.3%, p = 0.560). Revision for bleeding, dialysis, blood products, length-of-stay, gradients, and regurgitation was also equal. Risk analysis showed that low valve size, low ejection fraction, endocarditis, administration of red cells, and prolonged CPB time were predictors of elevated mortality. CONCLUSION: Isolated bovine AVR has low mortality. Valves ≥ 23 mm show comparable gradients while the valve model matters < 23 mm. RDV should be used with care. Procedure-related times are shorter than those of CV but pacemaker implantation and neurologic events are more frequent (Perceval). Early mortality is low and valve performance comparable to CV.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hemodinâmica , Idoso , Animais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Bovinos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
5.
Thorac Cardiovasc Surg ; 68(4): 322-327, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31747695

RESUMO

BACKGROUND: Prosthetic replacement of aneurysms of the ascending aorta is the gold standard in terms of long-term stability. Wrapping seems to be a less invasive procedure. It has not yet been shown if it is as safe in terms of long-term outcome. METHODS: We present a single-center analysis of our experience over 13 years. We retrospectively analyzed data from patients who received either aortic prosthetic wrapping (AW) or aortic prosthetic replacement (AR) with or without aortic valve replacement and assessed them through phone calls. We used propensity score matching to adjust the baseline of the groups. RESULTS: Before propensity matching, 144 patients received AW and 91 patients underwent AR. Mean age was 64 ± 11.8 years. After propensity score matching and adjusting for significant differences in age, gender, body mass index, logistic EuroSCORE I, and left ventricular function, 69 patients in each group remained for further analysis. Rate of early reoperation due to tamponade, inhospital mortality, and survival rates did not differ. In both groups, the surgically treated aortic segment did not show enlargement, whereas the nontreated aortic arch showed comparable aneurysmatical progression. CONCLUSIONS: AW is safe and feasible and can be used in elderly or frail patients in order to avoid an AR. Progression of the remaining native aortic segments occurs, thus requiring strict life-long follow-up to ensure an elective and thus safe approach for appropriate consecutive surgical measures, if required.


Assuntos
Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular , Procedimentos Cirúrgicos Vasculares , Idoso , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/mortalidade
7.
Thorac Cardiovasc Surg Rep ; 7(1): e24-e26, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29977734

RESUMO

Background Acute endovascular aneurysm repair with stent grafts (thoracic endovascular aortic repair [TEVAR]) is safe and feasible. Case Description A 64-year-old female presented with a perforated aortic aneurysm of the thoracic descending aorta. Primary TEVAR resulted in good management of the perforation but a type Ib endoleakage remained postoperatively. To place another stent, abdominal debranching with saphenous vein bypass to the celiac trunk was required. In the same session, another endograft was inserted successfully. Conclusion Abdominal debranching is a safe alternative to open aortic repair in acute thoracic and abdominal aneurysms, instead of waiting for a custom-made device.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...