Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acc Chem Res ; 34(12): 963-72, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11747414

RESUMO

Most synthetic sensors are designed with covalent attachment between a receptor and a reporter moiety. In this report, we describe the current progress of our use of noncovalently attached indicators to signal binding of analytes. With these systems, analyte binding leads to indicator displacement from the binding cavity, which in turn yields an optical signal modulation. We include previous examples, the strategies involved in our development, and the advantages as well as disadvantages of this method. Finally, our latest research in this field is briefly presented.


Assuntos
Técnicas Biossensoriais , Indicadores e Reagentes/química , Sítios de Ligação , Ácido Cítrico/análise , Ácido Cítrico/química , Glucose-6-Fosfato/análise , Glucose-6-Fosfato/química , Inositol 1,4,5-Trifosfato/análise , Inositol 1,4,5-Trifosfato/química , Nitratos/análise , Nitratos/química , Tartaratos/análise , Tartaratos/química
2.
J Am Chem Soc ; 123(11): 2559-70, 2001 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-11456925

RESUMO

The development of a chip-based sensor array composed of individually addressable polystyrene-poly(ethylene glycol) and agarose microspheres has been demonstrated. The microspheres are selectively arranged in micromachined cavities localized on silicon wafers. These cavities are created with an anisotropic etch and serve as miniaturized reaction vessels and analysis chambers. A single drop of fluid provides sufficient analysis media to complete approximately 100 assays in these microetch pits. The cavities possess pyramidal pit shapes with trans-wafer openings that allows for both fluid flow through the microreactors/analysis chambers and optical access to the chemically sensitive microspheres. Identification and quantitation of analytes occurs via colorimetric and fluorescence changes to receptor and indicator molecules that are covalently attached to termination sites on the polymeric microspheres. Spectral data are extracted from the array efficiently using a charge-coupled device allowing for the near-real-time digital analysis of complex fluids. The power and utility of this new microbead array detection methodology is demonstrated here for the analysis of complex fluids containing a variety of important classes of analytes including acids, bases, metal cations, metabolic cofactors, and antibody reagents.


Assuntos
Técnicas de Química Analítica , Polímeros , Colorimetria , Concentração de Íons de Hidrogênio , Microesferas
3.
Org Lett ; 3(9): 1311-4, 2001 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-11348222

RESUMO

[structure in text] The pK(a) values and the geometries of secondary and tertiary amines adjacent to boronic acids were determined using potentiometric and (11)B NMR titrations. The studies showed that the secondary ammonium ion has a pK(a) similar to that of the tertiary ammonium species, which leads to the formation of tetrahedral boron centers at pH values above approximately 5.5. Therefore, secondary amines as well as tertiary amines, when placed proximal to boron centers, can be used to create tetrahedral boronic acids at neutral pH for diol complexation.


Assuntos
Aminas/química , Ácidos Borônicos/química , Cristalografia por Raios X , Concentração de Íons de Hidrogênio , Espectroscopia de Ressonância Magnética , Modelos Moleculares , Estrutura Molecular , Compostos de Amônio Quaternário/química , Relação Estrutura-Atividade
SELEÇÃO DE REFERÊNCIAS