1.
Clin Biochem ; 48(4-5): 204-12, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25661303

RESUMO

OBJECTIVES: This article is a systematic review of the effectiveness of four practices (assay selection, decision point cardiac troponin (cTn) threshold selection, serial testing, and point of care testing) for improving the diagnostic accuracy Non-ST-Segment Elevation Myocardial Infarction (NSTEMI) in the Emergency Department. DESIGN AND METHODS: The CDC-funded Laboratory Medicine Best Practices (LMBP) Initiative systematic review method for quality improvement practices was used. RESULTS: The current ACC/AHA guidelines recommend using cardiac troponin assays with a 99th percentile upper reference limit (URL) diagnostic threshold to diagnose NSTEMI. The evidence in this systematic review indicates that contemporary sensitive cTn assays meet the assay profile requirements (sensitivity, specificity, PPV, and NPV) to more accurately diagnose NSTEMI than alternate tests. Additional biomarkers did not increase diagnostic effectiveness of cTn assays. Sensitivity, specificity, and NPV were consistently high and low PPV improved with serial sampling. Evidence for use of point of care cTn testing was insufficient to make recommendation, though some evidence suggests that use may result in reduction to patient length of stay and costs. CONCLUSIONS: Based on the review of and the LMBP(TM) A-6 Method criteria, we recommend the use of cardiac troponin assays without additional biomarkers using the 99th percentile URL as the clinical diagnostic threshold for the diagnosis of NSTEMI. We recommend serial sampling with one sample at presentation and at least one additional second sample taken at least 6h later to identify a rise or fall in the troponin level. No recommendation is made either for or against the use of point of care tests. DISCLAIMER: The findings and conclusions in this article are those of the authors and do not necessarily represent the official position of the Centers for Disease Control and Prevention/the Agency for Toxic Substances and Disease Registry (CDC/ATSDR).


Assuntos
Serviço Hospitalar de Emergência/normas , Infarto do Miocárdio/sangue , Infarto do Miocárdio/diagnóstico , Biomarcadores/sangue , Humanos , Guias de Prática Clínica como Assunto/normas , Troponina/sangue , Troponina I/sangue , Troponina T/sangue
2.
Clin Biochem ; 45(13-14): 999-1011, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22709932

RESUMO

OBJECTIVES: This article is a systematic review of the effectiveness of three practices for reducing blood culture contamination rates: venipuncture, phlebotomy teams, and prepackaged preparation/collection (prep) kits. DESIGN AND METHODS: The CDC-funded Laboratory Medicine Best Practices Initiative systematic review methods for quality improvement practices were used. RESULTS: Studies included as evidence were: 9 venipuncture (vs. versus intravenous catheter), 5 phlebotomy team; and 7 prep kit. All studies for venipuncture and phlebotomy teams favored these practices, with meta-analysis mean odds ratios for venipuncture of 2.69 and phlebotomy teams of 2.58. For prep kits 6 studies' effect sizes were not statistically significantly different from no effect (meta-analysis mean odds ratio 1.12). CONCLUSIONS: Venipuncture and the use of phlebotomy teams are effective practices for reducing blood culture contamination rates in diverse hospital settings and are recommended as evidence-based "best practices" with high overall strength of evidence and substantial effect size ratings. No recommendation is made for or against prep kits based on uncertain improvement.


Assuntos
Bactérias/isolamento & purificação , Sangue/microbiologia , Erros de Diagnóstico/prevenção & controle , Flebotomia/normas , Guias de Prática Clínica como Assunto/normas , Avaliação de Programas e Projetos de Saúde/métodos , Técnicas de Cultura de Células/normas , Centers for Disease Control and Prevention, U.S. , Contaminação de Equipamentos/prevenção & controle , Reações Falso-Positivas , Humanos , Razão de Chances , Melhoria de Qualidade/normas , Kit de Reagentes para Diagnóstico/normas , Estados Unidos
SELEÇÃO DE REFERÊNCIAS