Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Molecules ; 26(10)2021 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-34065944

RESUMO

Stable, oil-in-water nanoemulsions containing astaxanthin (AsX) were produced by intense fluid shear forces resulting from pumping a coarse reagent emulsion through a self-throttling annular gap valve at 300 MPa. Compared to crude emulsions prepared by conventional homogenization, a size reduction of over two orders of magnitude was observed for AsX-encapsulated oil droplets following just one pass through the annular valve. In krill oil formulations, the mean hydrodynamic diameter of lipid particles was reduced to 60 nm after only two passes through the valve and reached a minimal size of 24 nm after eight passes. Repeated processing of samples through the valve progressively decreased lipid particle size, with an inflection in the rate of particle size reduction generally observed after 2-4 passes. Krill- and argan oil-based nanoemulsions were produced using an Ultra Shear Technology™ (UST™) approach and characterized in terms of their small particle size, low polydispersity, and stability.


Assuntos
Antioxidantes/química , Clorofíceas/química , Composição de Medicamentos/métodos , Extratos Vegetais/química , Óleos de Plantas/química , Água/química , Animais , Estabilidade de Medicamentos , Emulsões , Euphausiacea/química , Tamanho da Partícula , Xantofilas/química
2.
J Chem Phys ; 149(12): 124302, 2018 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-30278665

RESUMO

The long-range dispersion C6 coefficient for the SF6 dimer is experimentally measured using a technique that uses the expansion of a supersonic pulse jet into a vacuum. A dynamic model of the jet enables us to correlate the position of the maximal peak in the time-of-flight spectrum with the initial conditions of the experiment and the parameters of the intermolecular interaction potential. Due to the low temperature of the jet target, the C6 coefficient can be extracted directly from the experimental results. Theoretical calculation of the C6 dispersion coefficient is also performed by using linearly approximated explicitly correlated coupled-cluster singles and doubles (CCSD(F12)) method with the subsequent utilization of the Casimir-Polder formula. Good agreement of experimental and theoretical results confirms the reliability of results.

3.
Anal Chem ; 85(2): 1114-23, 2013 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-23210743

RESUMO

Robust methodologies for the analysis of fecal material will facilitate the understanding of gut (patho)physiology and its role in health and disease and will help improve care for individual patients, especially high-risk populations, such as premature infants. Because lipidomics offers a biologically and analytically attractive approach, we developed a simple, sensitive, and quantitatively precise method for profiling intact lipids in fecal material. The method utilizes two separate, complementary extraction chemistries, dichloromethane (DCM) and a methyl tert-butyl ether/hexafluoroisopropanol (MTBE) mixture, alone or with high pressure cycling. Extracts were assessed by liquid chromatography-high-resolution mass spectrometry-based profiling with all ion higher energy collisional dissociation fragmentation in both positive and negative ionization modes. This approach provides both class-specific and lipid-specific fragments, enhancing lipid characterization. Solvents preferentially extracted lipids based on hydrophobicity. More polar species preferred MTBE; more hydrophobic compounds preferred DCM. Pressure cycling differentially increased the yield of some lipids. The platform enabled analysis of >500 intact lipophilic species with over 300 lipids spanning 6 LIPID MAPS categories identified in the fecal matter from premature infants. No previous report exists that provides these data; thus, this study represents a new paradigm for assessing nutritional health, inflammation, and infectious disease in vulnerable populations.


Assuntos
Lipídeos/análise , Cromatografia Líquida de Alta Pressão , Humanos , Interações Hidrofóbicas e Hidrofílicas , Lactente , Espectrometria de Massas , Éteres Metílicos/química , Cloreto de Metileno/química , Propanóis/química
4.
Methods Mol Biol ; 881: 27-62, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22639209

RESUMO

Systems biologists frequently seek to integrate complex data sets of diverse analytes into a comprehensive picture of an organism's biological state under defined environmental conditions. Although one would prefer to collect these data from the same sample, technical limitations with traditional sample preparation methods often commit the investigator to extracting one type of analyte at the expense of losing all others. Often, volume further constrains the range of experiments that can be collected from a single sample. The practical solution employed to date has been to rely on information collected from multiple replicate experiments and similar historical or reported data. While this approach has been popular, the integration of information collected from disparate single-analyte sample preparation streams increases uncertainty due to nonalignment during comparative analysis, and such gaps accumulate quickly when combining multiple data sets. Regrettably, discontinuities between separate data streams can confound a whole understanding of the biological system being investigated. This difficulty is further compounded for researchers handling highly pathogenic samples, in which it is often necessary to use harsh chemicals or high-energy sterilization procedures that damage the target analytes. Ultra-high pressure cycling technology (PCT), also known as barocycling, is an emerging sample preparation strategy that has distinct advantages for systems biology studies because it neither commits the researcher to pursuing a specific analyte nor leads to the degradation of target material. In fact, samples prepared under pressure cycling conditions have been shown to yield a more complete set of analytes due to uniform disruption of the sample matrix coupled with an advantageous high pressure solvent environment. Fortunately, PCT safely sterilizes and extracts complex or pathogenic viral, bacterial, and spore samples without adversely affecting the constituent biomolecules valued as informative and meaningful analytes. This chapter provides procedures and findings associated with incorporating PCT into systems biology as a new and enabling approach to preanalytical sample treatment.


Assuntos
Biologia de Sistemas/instrumentação , Biologia de Sistemas/métodos , Animais , Fracionamento Celular/métodos , DNA Bacteriano/genética , DNA Mitocondrial/genética , Humanos , Oligopeptídeos/química , Oligopeptídeos/isolamento & purificação
5.
Anal Biochem ; 418(2): 213-23, 2011 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-21820998

RESUMO

Isolation of functional and intact mitochondria from solid tissue is crucial for studies that focus on the elucidation of normal mitochondrial physiology and/or mitochondrial dysfunction in conditions such as aging, diabetes, and cancer. There is growing recognition of the importance of mitochondria both as targets for drug development and as off-target mediators of drug side effects. Unfortunately, mitochondrial isolation from tissue is generally carried out using homogenizer-based methods that require extensive operator experience to obtain reproducible high-quality preparations. These methods limit dissemination, impede scale-up, and contribute to difficulties in reproducing experimental results over time and across laboratories. Here we describe semiautomated methods to disrupt tissue using kidney and muscle mitochondria preparations as exemplars. These methods use the Barocycler, the PCT Shredder, or both. The PCT Shredder is a mechanical grinder that quickly breaks up tissue without significant risk of overhomogenization. Mitochondria isolated using the PCT Shredder are shown to be comparable to controls. The Barocycler generates controlled pressure pulses that can be adjusted to lyse cells and release organelles. The mitochondria subjected to pressure cycling-mediated tissue disruption are shown to retain functionality, enabling combinations of the PCT Shredder and the Barocycler to be used to purify mitochondrial preparations.


Assuntos
Métodos Analíticos de Preparação de Amostras/métodos , Técnicas Citológicas/métodos , Rim/metabolismo , Mitocôndrias Musculares/metabolismo , Músculo Esquelético/metabolismo , Animais , Humanos , Pressão Hidrostática , Rim/citologia , Masculino , Membranas Mitocondriais/metabolismo , Músculo Esquelético/citologia , Ratos
6.
Electrophoresis ; 30(6): 966-73, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19309014

RESUMO

Modern proteomic research frequently relies upon separation of proteins in a polyacrylamide gel matrix followed by in-gel enzymatic digestion and extraction of peptides for subsequent analysis by MS. In this work, we propose a novel semi-automated method of mechanical processing of gel bands by passing these bands through a specially designed centrifugal device termed a Gel Shredder prior to digestion and extraction of peptides. Such a device allows integrated washing, destaining and shredding of gel bands into uniform blocks of controlled size, approximately 150-300 microm, prior to the enzymatic digestion and extraction of peptides. Shredding into uniform blocks increases the surface area of the gel pieces and promotes improved gel rehydration, allowing improved diffusion of the proteolytic enzymes and solvent into the gel lattice. We demonstrate that the new method substantially reduces the time spent on tedious manual handling of gel bands, while minimizing the risk of sample contamination. The performance of the Gel Shredder has been compared with a conventional in-gel digestion protocol using several standard proteins and a complex proteomic sample in terms of relative quantitation by either MALDI-TOF/TOF or nanoLC-ESI IT-Fourier transformation ion cyclotron resonance MS. It is shown that significant time savings and improved peptide recovery can be obtained for many proteins using the Gel Shredder compared with the traditional in-gel digestion protocol.


Assuntos
Centrifugação , Eletroforese em Gel de Poliacrilamida , Espectrometria de Massas , Fragmentos de Peptídeos , Mapeamento de Peptídeos , Tecido Adiposo/química , Animais , Cromatografia Líquida , Bases de Dados de Proteínas , Desenho de Equipamento , Camundongos , Fragmentos de Peptídeos/análise , Fragmentos de Peptídeos/metabolismo , Mapeamento de Peptídeos/instrumentação , Mapeamento de Peptídeos/métodos , Proteínas/análise , Proteínas/metabolismo , Proteômica/instrumentação , Proteômica/métodos , Tripsina/metabolismo
7.
J Proteome Res ; 5(4): 983-7, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16602706

RESUMO

Reduction and alkylation of protein disulfides prior to IEF, when performed directly in a centrifugal ultrafiltration device, provides an effective means of terminating the alkylation reaction, concentrating the proteins for analysis, and removing ionic impurities that interfere with IEF. When cells were lysed in "buffers" that support the activity of enzymes such as lysozyme and benzonase, the conductivity of the resulting lysate was an order of magnitude higher than when lysis was induced by chaotropic urea detergent solutions. Following reduction and alkylation, the conductivity of both lysates was lowered by ultrafiltration to the 0.1-0.2 mS/cm range in preparation for IEF. The detergent 3-(4-heptyl)phenyl 3-hydroxypropyl dimethylammonio propanesulfonate (C7BzO), which favors the solubilization of proteins, but which interferes with SDS equilibration and second dimension PAGE, was effectively removed by ultrafiltration and exchanged with CHAPS without measurable loss of protein. Disparate protein patterns of Rhodopseudomonas palustris lysates were revealed by two-dimensional gel electrophoresis depending on which reagent was used to induce cell lysis.


Assuntos
Dissulfetos/química , Eletroforese em Gel Bidimensional , Proteínas/química , Alquilação , Extratos Celulares/química , Centrifugação , Detergentes/farmacologia , Eletroforese em Gel de Poliacrilamida , Focalização Isoelétrica , Oxirredução , Mapeamento de Peptídeos , Rodopseudomonas/metabolismo , Solubilidade , Ultrafiltração/instrumentação , Ultrafiltração/métodos , Ureia/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...