Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 90(8): 083303, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31472608

RESUMO

The Time-of-Flight (TOF) technique coupled with semiconductorlike detectors, as silicon carbide and diamond, is one of the most promising diagnostic methods for high-energy, high repetition rate, laser-accelerated ions allowing a full on-line beam spectral characterization. A new analysis method for reconstructing the energy spectrum of high-energy laser-driven ion beams from TOF signals is hereby presented and discussed. The proposed method takes into account the detector's working principle, through the accurate calculation of the energy loss in the detector active layer, using Monte Carlo simulations. The analysis method was validated against well-established diagnostics, such as the Thomson parabola spectrometer, during an experimental campaign carried out at the Rutherford Appleton Laboratory (UK) with the high-energy laser-driven protons accelerated by the VULCAN Petawatt laser.

2.
Phys Med ; 54: 166-172, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30076107

RESUMO

The main purpose of this paper is to quantitatively study the possibility of delivering dose distributions of clinical relevance with laser-driven proton beams. A Monte Carlo application has been developed with the Geant4 toolkit, simulating the ELIMED (MEDical and multidisciplinary application at ELI-Beamlines) transport and dosimetry beam line which is being currently installed at the ELI-Beamlines in Prague (CZ). The beam line will be used to perform irradiations for multidisciplinary studies, with the purpose of demonstrating the possible use of optically accelerated ion beams for therapeutic purposes. The ELIMED Geant4-based application, already validated against reference transport codes, accurately simulates each single element of the beam line, necessary to collect the accelerated beams and to select them in energy. Transversal dose distributions at the irradiation point have been studied and optimized to try to quantitatively answer the question if such kind of beam lines, and specifically the systems developed for ELIMED in Prague, will be actually able to transport ion beams not only for multidisciplinary applications, such as pitcher-catcher nuclear reactions (e.g. neutrons), PIXE analysis for cultural heritage and space radiation, but also for delivering dose patterns of clinical relevance in a future perspective of possible medical applications.


Assuntos
Lasers , Método de Monte Carlo , Aceleradores de Partículas , Terapia com Prótons/instrumentação , Doses de Radiação , Radiometria , Dosagem Radioterapêutica
5.
Radiology ; 152(2): 435-42, 1984 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-6739811

RESUMO

Local cerebral blood flow was measured and mapped using xenon-enhanced x-ray transmission computed tomography. Studies involving 4-6 minutes of xenon-oxygen inhalation can be performed routinely in awake and anesthetized patients with acceptable patient tolerance and compliance. Several case studies of patients with acute and chronic ischemic injuries and other cerebral abnormalities are presented to illustrate characterization of flow pattern in normal and abnormal tissue, as well as the relevance of this flow information to clinical patient management.


Assuntos
Arteriopatias Oclusivas/diagnóstico por imagem , Lesões Encefálicas/diagnóstico por imagem , Circulação Cerebrovascular , Transtornos Cerebrovasculares/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Morte Encefálica/diagnóstico por imagem , Doenças das Artérias Carótidas/diagnóstico por imagem , Artéria Carótida Interna , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Radioisótopos de Xenônio
6.
Stroke ; 15(3): 443-50, 1984.
Artigo em Inglês | MEDLINE | ID: mdl-6729873

RESUMO

Cerebral blood flow mapping with the xenon-enhanced/CT method has become a useful clinical tool in the management of patients with occlusive cerebral vascular disease. Studies involving 4-5 minutes of inhaling a xenon/oxygen mixture (less than or equal to 35%) can now be performed routinely with acceptable patient tolerance and compliance. Four cases with acute and chronic ischemic injuries are reported here to illustrate the manner in which this method has been used to characterize flow pattern in such patients and the relevance of this flow information to clinical patient management.


Assuntos
Circulação Cerebrovascular , Transtornos Cerebrovasculares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Xenônio , Adulto , Idoso , Angiografia Cerebral , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...