Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Imaging Radiat Oncol ; 27: 100473, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37520640

RESUMO

Background and purpose Retrospective log file-based analysis provides the actual dose delivered based on the patient's breathing and the daily beam-delivery dynamics. To predict the motion sensitivity of the treatment plan on a patient-specific basis before treatment start a prospective tool is required. Such a parameter-based tool has been investigated with the aim to be used in clinical routine. Materials and Methods 4D dose calculations (4DDC) were performed for seven cancer patients with small breathing motion treated with scanned pulsed proton beams. Validation of the parameter-based 4DDC (p-4DDC) method was performed with an anthropomorphic phantom and patient data employing measurements and a log file-based 4DDC tool. The dose volume histogram parameters (Dx%) were investigated for the target and the organs at risk, compared to static and the file-based approach. Results The difference between the measured and the p-4DDC dose was within the deviation of the measurements. The maximum deviation was 0.4Gy. For the planning target volume D98% varied up to 15% compared to the static scenario, while the results from the log file and p-4DDC agreed within 2%. For the liver patients, D33%liver deviated up to 35% compared to static and 10% comparing the two 4DDC tools, while for the pancreas patients the D1%stomach varied up to 45% and 11%, respectively. Conclusion The results showed that p-4DDC could be used prospectively. The next step will be the clinical implementation of the p-4DDC tool, which can support a decision to either adapt the treatment plan or apply motion mitigation strategies.

2.
Cancers (Basel) ; 15(9)2023 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-37174016

RESUMO

Motion compensation strategies in particle therapy depend on the anatomy, motion amplitude and underlying beam delivery technology. This retrospective study on pancreas patients with small moving tumours analysed existing treatment concepts and serves as a basis for future treatment strategies for patients with larger motion amplitudes as well as the transition towards carbon ion treatments. The dose distributions of 17 hypofractionated proton treatment plans were analysed using 4D dose tracking (4DDT). The recalculation of clinical treatment plans employing robust optimisation for mitigating different organ fillings was performed on phased-based 4D computed tomography (4DCT) data considering the accelerator (pulsed scanned pencil beams delivered by a synchrotron) and the breathing-time structure. The analysis confirmed the robustness of the included treatment plans concerning the interplay of beam and organ motion. The median deterioration of D50% (ΔD50%) for the clinical target volume (CTV) and the planning target volume (PTV) was below 2%, while the only outlier was observed for ΔD98% with -35.1%. The average gamma pass rate over all treatment plans (2%/ 2 mm) was 88.8% ± 8.3, while treatment plans for motion amplitudes larger than 1 mm performed worse. For organs at risk (OARs), the median ΔD2% was below 3%, but for single patients, essential changes, e.g., up to 160% for the stomach were observed. The hypofractionated proton treatment for pancreas patients based on robust treatment plan optimisation and 2 to 4 horizontal and vertical beams showed to be robust against intra-fractional movements up to 3.7 mm. It could be demonstrated that the patient's orientation did not influence the motion sensitivity. The identified outliers showed the need for continuous 4DDT calculations in clinical practice to identify patient cases with more significant deviations.

3.
Cancers (Basel) ; 14(7)2022 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-35406558

RESUMO

Motion amplitudes, in need of mitigation for moving targets irradiated with pulsed carbon ions and protons, were identified to guide the decision on treatment and motion mitigation strategy. Measurements with PinPoint ionisation chambers positioned in an anthropomorphic breathing phantom were acquired to investigate different tumour motion scenarios, including rib and lung movements. The effect of beam delivery dynamics and spot characteristics was considered. The dose in the tumour centre was deteriorated up to 10% for carbon ions but only up to 5% for protons. Dose deviations in the penumbra increased by a factor of two when comparing carbon ions to protons, ranging from 2 to 30% for an increasing motion amplitude that was strongly dependent on the beam intensity. Layer rescanning was able to diminish the dose distortion caused by tumour motion, but an increase in spot size could reduce it even further to 5% within the target and 10% at the penumbra. An increased need for motion mitigation of carbon ions compared to protons was identified to assure target coverage and sparing of adjacent organs at risk in the penumbra region and outside the target. For the clinical implementation of moving target treatments at a synchrotron-based particle facility complex, time dependencies needed to be considered.

4.
Med Phys ; 48(8): 4506-4522, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34091930

RESUMO

PURPOSE: Eye-dedicated proton therapy (PT) facilities are used to treat malignant intraocular lesions, especially uveal melanoma (UM). The first commercial ocular PT beamline from Varian was installed in the Netherlands. In this work, the conceptual design of the new eyeline is presented. In addition, a comprehensive comparison against five PT centers with dedicated ocular beamlines is performed, and the clinical impact of the identified differences is analyzed. MATERIAL/METHODS: The HollandPTC eyeline was characterized. Four centers in Europe and one in the United States joined the study. All centers use a cyclotron for proton beam generation and an eye-dedicated nozzle. Differences among the chosen ocular beamlines were in the design of the nozzle, nominal energy, and energy spectrum. The following parameters were collected for all centers: technical characteristics and a set of distal, proximal, and lateral region measurements. The measurements were performed with detectors available in-house at each institution. The institutions followed the International Atomic Energy Agency (IAEA) Technical Report Series (TRS)-398 Code of Practice for absolute dose measurement, and the IAEA TRS-398 Code of Practice, its modified version or International Commission on Radiation Units and Measurements Report No. 78 for spread-out Bragg peak normalization. Energy spreads of the pristine Bragg peaks were obtained with Monte Carlo simulations using Geant4. Seven tumor-specific case scenarios were simulated to evaluate the clinical impact among centers: small, medium, and large UM, located either anteriorly, at the equator, or posteriorly within the eye. Differences in the depth dose distributions were calculated. RESULTS: A pristine Bragg peak of HollandPTC eyeline corresponded to the constant energy of 75 MeV (maximal range 3.97 g/cm2 in water) with an energy spread of 1.10 MeV. The pristine Bragg peaks for the five participating centers varied from 62.50 to 104.50 MeV with an energy spread variation between 0.10 and 0.70 MeV. Differences in the average distal fall-offs and lateral penumbrae (LPs) (over the complete set of clinically available beam modulations) among all centers were up to 0.25 g/cm2 , and 0.80 mm, respectively. Average distal fall-offs of the HollandPTC eyeline were 0.20 g/cm2 , and LPs were between 1.50 and 2.15 mm from proximal to distal regions, respectively. Treatment time, around 60 s, was comparable among all centers. The virtual source-to-axis distance of 120 cm at HollandPTC was shorter than for the five participating centers (range: 165-350 cm). Simulated depth dose distributions demonstrated the impact of the different beamline characteristics among institutions. The largest difference was observed for a small UM located at the posterior pole, where a proximal dose between two extreme centers was up to 20%. CONCLUSIONS: HollandPTC eyeline specifications are in accordance with five other ocular PT beamlines. Similar clinical concepts can be applied to expect the same high local tumor control. Dosimetrical properties among the six institutions induce most likely differences in ocular radiation-related toxicities. This interinstitutional comparison could support further research on ocular post-PT complications. Finally, the findings reported in this study could be used to define dosimetrical guidelines for ocular PT to unify the concepts among institutions.


Assuntos
Terapia com Prótons , Neoplasias Uveais , Humanos , Melanoma , Método de Monte Carlo , Dosagem Radioterapêutica , Neoplasias Uveais/radioterapia
5.
J Physiol ; 599(5): 1533-1550, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33369737

RESUMO

KEY POINTS: The post-exercise recovery of phosphocreatine, a measure of the oxidative capacity of muscles, as assessed by 31 P MR spectroscopy, shows a striking increase from distal to proximal along the human tibialis anterior muscle. To investigate why this muscle exhibits a greater oxidative capacity proximally, we tested whether the spatial variation in phosphocreatine recovery rate is related to oxygen supply, muscle fibre type or type of exercise. We revealed that oxygen supply also increases from distal to proximal along the tibialis anterior, and that it strongly correlated with phosphocreatine recovery. Carnosine level, a surrogate measure for muscle fibre type was not different between proximal and distal, and type of exercise did not affect the gradient in phosphocreatine recovery rate. Taken together, the findings of this study suggest that the post-exercise spatial gradients in oxygen supply and phosphocreatine recovery are driven by a higher intrinsic mitochondrial oxidative capacity proximally. ABSTRACT: Phosphorus magnetic resonance spectroscopy (31 P MRS) of human tibialis anterior (TA) revealed a strong proximo-distal gradient in the post-exercise phosphocreatine (PCr) recovery rate constant (kPCr ), a measure of muscle oxidative capacity. The aim of this study was to investigate whether this kPCr gradient is related to O2 supply, resting phosphorylation potential, muscle fibre type, or type of exercise. Fifteen male volunteers performed continuous isometric ankle dorsiflexion at 30% maximum force until exhaustion. At multiple locations along the TA, we measured the oxidative PCr resynthesis rate (VPCr = kPCr × PCr depletion) by 31 P MRS, the oxyhaemoglobin recovery rate constant (kO2Hb ) by near infrared spectroscopy, and muscle perfusion with MR intravoxel incoherent motion imaging. The kO2Hb , kPCr , VPCr and muscle perfusion depended on measurement location (P < 0.001, P < 0.001, P = 0.032 and P = 0.003, respectively), all being greater proximally. The kO2Hb and muscle perfusion correlated with kPCr (r = 0.956 and r = 0.852, respectively) and VPCr (r = 0.932 and r = 0.985, respectively), the latter reflecting metabolic O2 consumption. Resting phosphorylation potential (PCr/inorganic phosphate) was also higher proximally (P < 0.001). The surrogate for fibre type, carnosine content measured by 1 H MRS, did not differ between distal and proximal TA (P = 0.884). Performing intermittent exercise to avoid exercise ischaemia, still led to larger kPCr proximally than distally (P = 0.013). In conclusion, the spatial kPCr gradient is strongly associated with the spatial variation in O2 supply. It cannot be explained by exercise-induced ischaemia nor by fibre type. Our findings suggest it is driven by a higher proximal intrinsic mitochondrial oxidative capacity, apparently to support contractile performance of the TA.


Assuntos
Exercício Físico , Músculo Esquelético , Trifosfato de Adenosina , Humanos , Masculino , Contração Muscular , Fosfocreatina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...