Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Vasa ; 47(5): 393-401, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29952252

RESUMO

BACKGROUND: Vascular access site-related complications are frequent in the context of transfemoral transcatheter aortic valve replacement (TAVR). The implantation of a covered stent graft is an effective treatment option for bleeding control. However, the external iliac and common femoral arteries are exposed to flexion of the hip joint. Therefore, stent compression and stent/strut fractures may occur, facilitating stent occlusion. PATIENTS AND METHODS: In all 389 patients who received transfemoral TAVR from 2013-2015 at the Düsseldorf Heart Centre, we monitored the management of vascular access site-related complications. Our analyses focused on immediate technical success and bleeding control, primary patency, and the occurrence of stent/strut fractures after six to 12 months of follow-up. RESULTS: Vascular access site-related complications occurred in 13 % (n = 51), whereof in 10 patients, the bleeding was successfully managed by prolonged compression. In 40 out of 51 patients, a covered stent graft was implanted in the common femoral artery, leading to 100 % immediate bleeding control. After a mean follow-up of 334 ± 188 days, 28 stents out of 29 patients with completed follow-up (excluding e. g. death) were without flow-limiting stenosis (primary patency 97 %) or relevant stent compression (diameter pre/post 8.6/8.1 mm, p = 0.048, late lumen loss 1.1 ± 0.2 mm, mean flow velocity 92 ± 34 cm/s). In four asymptomatic patients, stent/strut fractures were detected (14 %) without flow-limiting stenosis. CONCLUSIONS: The implantation of a covered stent graft is highly effective and safe to control vascular access site-related complications after TAVR. Stent/strut fractures in the flexible segment of the common femoral artery may occur, as consequently verified by X-ray visualization, but show no impairment on flow or clinical parameters after six to 12 months.


Assuntos
Implante de Prótese Vascular/instrumentação , Prótese Vascular , Cateterismo Periférico/métodos , Procedimentos Endovasculares/instrumentação , Artéria Femoral/cirurgia , Hemorragia/cirurgia , Falha de Prótese , Stents , Técnicas de Sutura/instrumentação , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Implante de Prótese Vascular/efeitos adversos , Cateterismo Periférico/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Alemanha , Hemorragia/diagnóstico por imagem , Hemorragia/etiologia , Humanos , Masculino , Desenho de Prótese , Punções , Fluxo Sanguíneo Regional , Técnicas de Sutura/efeitos adversos , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...