Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 10(11): e32667, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38912484

RESUMO

Background and objective: Inferior vena cava filters have been shown to be effective in preventing deep vein thrombosis and its secondary complication, pulmonary embolism, thereby reducing the high mortality rate. Although inferior vena cava filters have evolved, specific complications like inferior vena cava thrombosis-induced deep vein thrombosis worsening and recurrent pulmonary embolism continue to pose challenges. This study analyzes the effects of geometric parameter variations of inferior vena cava filters, which have a significant impact on the thrombus formation inside the filter, the capture, dissolution, and hemodynamic flow of thrombus, as well as the shear stress on the filter and vascular wall. Methods: This study used computational fluid dynamic simulations with the carreau model to investigate the impact of varying inferior vena cava filter design parameters (number of struts, strut arm length, and tilt angle) on hemodynamics. Results: Recirculation and stagnation areas due to flow velocity and pressure, along with wall shear stress values, were identified as key factors. It is important to find a balance between wall shear stress high enough to aid thrombolysis and low enough to prevent platelet activation. The results of this paper show that the risk of platelet activation and thrombus filtration may be lowest when the wall shear stress of the filter ranges from 0 to 4 [Pa], minimizing stress concentration within the filter. Conclusion: 16 arm struts with a length of 20 mm and a tilt angle of 0° provide the best balance between thrombus capture and minimization of hemodynamic disturbance. This configuration minimizes the size of the stagnation and recirculation zones while maintaining sufficient wall shear stress for thrombus dissolution.

2.
Heliyon ; 10(7): e28176, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38633651

RESUMO

In this study, the nonlinear deflection of an infinite beam with variable beam cross-sections on a nonlinear elastic foundation was analyzed using the pseudo-parameter iteration method (PIM), which is a novel iterative semi-analytic method for solving ordinary/partial differential equations. To do this, we set six types of infinite beams with concave and convex shapes under static loading conditions. To calculate the nonlinear deflection of the infinite beam with variable cross-sections, the Bernoulli-Euler beam equation (fourth-order ordinary differential equation) considering changing beam flexural rigidity was introduced, and the PIM was adopted to this equation. Through the numerical experiment, it was confirmed that the nonlinear deflections calculated via the PIM are quite close to the exact solution within a few iterations. In addition, the graph of error quickly reaches the steady state error for all cases as the number of iterations increases.

3.
Front Bioeng Biotechnol ; 12: 1294658, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38600941

RESUMO

The facet joint contributes to lumbar spine stability as it supports the weight of body along with the intervertebral discs. However, most studies on the causes of degenerative lumbar diseases focus on the intervertebral discs and often overlook the facet joints. This study aimed to investigate the impact of facet joint degeneration on the degenerative changes and diseases of the lumbar spine. A finite element model of the lumbar spine (L1-S1) was fabricated and validated to study the biomechanical characteristics of the facet joints. To simulate degeneration of the facet joint, the model was divided into four grades based on the number of degenerative segments (L4-L5 or L4-S1) and the contact condition between the facet joint surfaces. Finite element analysis was performed on four spine motions: flexion, extension, lateral bending, and axial torsion, by applying a pure moment to the upper surface of L1. Important parameters that could be used to confirm the effect of facet joint degeneration on the lumbar spine were calculated, including the range of motion (ROM) of the lumbar segments, maximum von Mises stress on the intervertebral discs, and reaction force at the facet joint. Facet joint degeneration affected the biomechanical characteristics of the lumbar spine depending on the movements of the spine. When analyzed by dividing it into degenerative onset and onset-adjacent segments, lumbar ROM and the maximum von Mises stress of the intervertebral discs decreased as the degree of degeneration increased in the degenerative onset segments. The reaction force at the facet joint decreased with flexion and increased with lateral bending and axial torsion. In contrast, lumbar ROM of the onset-adjacent segments remained almost unchanged despite severe degeneration of the facet joint, and the maximum von Mises stress of the intervertebral discs increased with flexion and extension but decreased with lateral bending and axial torsion. Additionally, the facet joint reaction force increased with extension, lateral bending, and axial rotation. This analysis, which combined the ROM of the lumbar segment, maximum von Mises stress on the intervertebral disc, and facet joint reaction force, confirmed the biomechanical changes in the lumbar spine due to the degeneration of isolated facet joints under the load of spinal motion. In the degenerative onset segment, spinal instability decreased, whereas in the onset-adjacent segment, a greater load was applied than in the intact state. When conducting biomechanical studies on the lumbar spine, considering facet joint degeneration is important since it can lead to degenerative spinal diseases, including adjacent segment diseases.

4.
Front Bioeng Biotechnol ; 12: 1305128, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38476969

RESUMO

Vascular diseases, such as abdominal aortic aneurysms, are associated with tissue degeneration of the aortic wall, resulting in variations in mechanical properties, such as tissue ultimate stress and a high slope. Variations in the mechanical properties of tissues may be associated with an increase in the number of collagen cross-links. Understanding the effect of collagen cross-linking on tissue mechanical properties can significantly aid in predicting diseased aortic tissue rupture and improve the clarity of decisions regarding surgical procedures. Therefore, this study focused on increasing the density of the aortic tissue through cross-linking and investigating the mechanical properties of the thoracic aortic tissue in relation to density. Uniaxial tensile tests were conducted on the porcine thoracic aorta in four test regions (anterior, posterior, distal, and proximal), two loading directions (circumferential and longitudinal), and density increase rates (0%-12%). As a result, the PPC (Posterior/Proximal/Circumferential) group experienced a higher ultimate stress than the PDC (Posterior/Distal/Circumferential) group. However, this relationship reversed when the specimen density exceeded 3%. In addition, the ultimate stress of the ADC (Anterior/Distal/Circumferential) and PPC group was greater than that of the APC (Anterior/Proximal/Circumferential) group, while these findings were reversed when the specimen density exceeded 6% and 9%, respectively. Finally, the high slope of the PDL (Posterior/Distal/Longitudinal) group was lower than that of the ADL (Anterior/Distal/Longitudinal) group, but the high slope of the PDL group appeared larger due to the stabilization treatment. This highlights the potential impact of density variations on the mechanical properties of specific specimen groups.

5.
Ann Biomed Eng ; 52(4): 1067-1077, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38302767

RESUMO

Surgical treatment of the pectus excavatum has led to the introduction of the Nuss procedure, a minimally invasive surgical procedure that involves inserting a metal bar under the sternum through a small lateral thoracic incision. An additional metal bar was inserted in patients with pectus excavatum to improve the retention of the restored chest wall after the Nuss procedure. However, a need still exists to analyze the mechanistic advantages and disadvantages of the double-bar method owing to the increased surgical time and proficiency. The purpose of this study is to compare and evaluate the efficiency of single- and double-bar methods using rotational and equilibrium displacement simulations of the Nuss procedure. A finite-element model was constructed for two types of metal bars inserted into the chest wall. Boundary conditions for the rotation and equilibrium displacements were set for the metal bar. The anterior sternal translation, Haller index and maximum equivalent stress and strain owing to the behavior of the metal bar were estimated and compared with the single-bar method and postoperatively acquired patient data. The simulation results showed that the influences of the intercostal muscle and equilibrium after rotation displacement were significant. The stresses and strains were distributed across the two metal bars, and the upper-metal bar was heavily loaded. The double-bar method was advantageous regarding the load distribution effects of the two metal bars on the chest wall. However, mechanical assessments are also important because an excessive load is typically applied to the upper-metal bar.


Assuntos
Tórax em Funil , Parede Torácica , Humanos , Tórax em Funil/cirurgia , Rotação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Metais , Resultado do Tratamento , Estudos Retrospectivos
7.
Front Bioeng Biotechnol ; 11: 1297420, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38026863

RESUMO

A novel Nuss procedure simulation was developed for patients with pectus excavatum considering the displacement of a metal bar and a chest wall model, including the intercostal muscles. However, this simulation was developed for a typical symmetrical patient among the various morphological types of pectus excavatum. Accordingly, this study aimed to validate and confirm the novel simulation for patients with eccentric and imbalanced types, which are severe types of pectus excavatum, considering factors such as depression depth and eccentricity among others. Three-dimensional models of chest walls and metal bars were created for three different types of patients. The rotation-equilibrium displacement and chest wall with intercostal muscles were set according to the methods and conditions of the novel Nuss procedure simulation. The anterior sternal translation and the Haller index derived from the simulation results were compared and verified using medical data from actual postoperative patients. Additionally, maximum equivalent stresses and strains were derived to confirm the suitability of the novel Nuss procedure for each patient type. The severe types had similar precision to the typical type when compared to the actual postoperative patient. Relatively high maximum equivalent stresses and strains were observed on the metal bars and sternum in the severe type, thereby predicting and confirming the biomechanical characteristics of these types. In conclusion, a novel Nuss procedure simulation for severe types was numerically validated. This underscores the importance of biomechanical evaluation through a novel Nuss procedure simulation when planning actual surgeries for severe types of cases.

8.
Phys Eng Sci Med ; 46(4): 1741-1753, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37787839

RESUMO

In this work, we proposed a novel computer modeling and simulation technique for motion tracking of lung bronchi (or tumors) under respiration using 9 cases of computed tomography (CT)-based patient-specific finite element (FE) models and Ogden's hyperelastic model. In the fabrication of patient-specific FE models for the respiratory system, various organs such as the mediastinum, diaphragm, and thorax that could affect the lung motions during breathing were considered. To describe the nonlinear material behavior of lung parenchyma, the comparative simulation for biaxial tension-compression of lung parenchyma was carried out using several hyperelastic models in ABAQUS, and then, Ogden's model was adopted as an optimal model. Based on the aforementioned FE models and Ogden's material model, the 9 cases of respiration simulation were carried out from exhalation to inhalation, and the motion of lung bronchi (or tumors) was tracked. In addition, the changes in lung volume, lung cross-sectional area on the axial plane during breathing were calculated. Finally, the simulation results were quantitatively compared to the inhalation/exhalation CT images of 9 subjects to validate the proposed technique. Through the simulation, it was confirmed that the average relative errors of simulation to clinical data regarding to the displacement of 258 landmarks in the lung bronchi branches of total subjects were 1.10%~2.67%. In addition, the average relative errors of those with respect to the lung cross-sectional area changes and the volume changes in the superior-inferior direction were 0.20%~5.00% and 1.29 ~ 9.23%, respectively. Hence, it was considered that the simulation results were coincided well with the clinical data. The novelty of the present study is as follows: (1) The framework from fabrication of the human respiratory system to validation of the bronchi motion tracking is provided step by step. (2) The comparative simulation study for nonlinear material behavior of lung parenchyma was carried out to describe the realistic lung motion. (3) Various organs surrounding the lung parenchyma and restricting its motion were considered in respiration simulation. (4) The simulation results such as landmark displacement, lung cross-sectional area/volume changes were quantitatively compared to the clinical data of 9 subjects.


Assuntos
Neoplasias Pulmonares , Movimento , Humanos , Respiração , Pulmão/diagnóstico por imagem , Pulmão/patologia , Brônquios/diagnóstico por imagem , Brônquios/patologia , Computadores
9.
Phys Eng Sci Med ; 46(4): 1629-1642, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37695510

RESUMO

The purpose of this study is to suggest a novel in silico Nuss procedure that can predict the results of chest wall deformity correction. Three-dimensional (3D) geometric and finite element model of the chest wall were built from the 15-year-old male adolescent patient's computed tomography (CT) image with pectus excavatum of the mild deformity. A simulation of anterior translating the metal bar (T) and a simulation of maintaining equilibrium after 180-degree rotation (RE) were performed respectively. A RE simulation using the chest wall finite element model with intercostal muscles (REM) was also performed. Finally, the quantitative results of each in silico Nuss procedure were compared with those of postoperative patient. Furthermore, various mechanical indicators were compared between simulations. This confirmed that the REM simulation results were most similar to the actual patient's results. Through two clinical indicators that can be compared with postoperative patient and mechanical indicators, the authors consider that the REM of silico Nuss procedure proposed in this study is best simulated the actual surgery.


Assuntos
Tórax em Funil , Parede Torácica , Adolescente , Humanos , Masculino , Simulação por Computador , Tórax em Funil/diagnóstico por imagem , Tórax em Funil/cirurgia , Parede Torácica/cirurgia
10.
Phys Eng Sci Med ; 46(3): 1101-1114, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37213051

RESUMO

This study describes a computational analysis technique for evaluating the effect of screw spacing and angle on the pediatric hip locking plate system in proximal femoral osteotomy in pediatric patients having DDH with an aberrant femoral head and femoral angle. Under static compressive load conditions, the stresses of the screw and bone were examined as the screw spacing and angle changed. The spacing and angle of various screws were specifically considered as variables in this study based on the pile mechanism studied in civil engineering. As with the group pile mechanism, the tighter the screw spacing under static compressive loads, the more the overlapping effect between the bone stresses and the screws develops, increasing the risk of injuring the patient's bone. Therefore, a series of simulations was performed to determine the optimal screw spacing and angles to minimize the overlapping effect of bone stress. In addition, a formula for determining the minimum screw spacing was proposed based on the computational simulation results. Finally, if the outcomes of this study are applied to pediatric patients with DDH in the pre-proximal femoral osteotomy stage, post-operative load-induced femur damage will be reduced.


Assuntos
Parafusos Ósseos , Fêmur , Humanos , Criança , Fêmur/cirurgia , Cabeça do Fêmur , Pressão , Osteotomia/métodos
11.
Sci Rep ; 13(1): 6387, 2023 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-37076517

RESUMO

Pulmonary contusion is an important risk factor for respiratory complications in trauma patients. Hence, we aimed to determine the relationship between the ratio of pulmonary contusion volume to the total lung volume and patient outcomes and the predictability of respiratory complications. We retrospectively included 73 patients with a pulmonary contusion on chest computed tomography (CT) from 800 patients with chest trauma admitted to our facility between January 2019 and January 2020. Chest injury severity was expressed as the ratio of pulmonary contusion volume to total lung volume by quantifying pulmonary contusion volume on chest CT. The cut-off value was 80%. Among the 73 patients with pulmonary contusion (77% males, mean age: 45.3 years), 28 patients had pneumonia, and five had acute respiratory distress syndrome. The number of patients in the severe risk group with > 20% of pulmonary contusion volume was 38, among whom 23 had pneumonia. For predicting pneumonia, the area under the receiver operating characteristic curves for the ratio of pulmonary contusion volume was 0.85 (95% confidence interval 0.76-0.95, p = 0.008); the optimal threshold was 70.4%. Quantifying pulmonary contusion volume using initial CT enables identifying patients with chest trauma at high risk of delayed respiratory complications.


Assuntos
Contusões , Lesão Pulmonar , Pneumonia , Transtornos Respiratórios , Traumatismos Torácicos , Ferimentos não Penetrantes , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Contusões/complicações , Contusões/diagnóstico por imagem , Lesão Pulmonar/etiologia , Lesão Pulmonar/complicações , Traumatismos Torácicos/complicações , Traumatismos Torácicos/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Pulmão/diagnóstico por imagem , Ferimentos não Penetrantes/complicações , Pneumonia/etiologia , Pneumonia/complicações , Medidas de Volume Pulmonar
12.
Front Bioeng Biotechnol ; 10: 1002276, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36277403

RESUMO

Recently, the objectives of lumbar interbody fusion (LIF) have been extended to include the correction of broader/relative indications in addition to spinal fixation. Accordingly, LIF must be optimized for sagittal alignment while simultaneously achieving decompression. Therefore, a representative model classified into three pelvic types, i.e., neutral pelvis (NP), anterior pelvis (AP), and retroverted pelvis (RP), was selected according to the pelvic index, and LIF was performed on each representative model to analyze Lumbar lordosis (LL) and the corresponding equivalent stress. The finite element (FE) model was based on a sagittal 2D X-ray image. The calculation efficiency and convergence were improved by simplifying the modeling of the vertebral body in general and its posterior portion in particular. Based on the position of the pelvis, according to the pelvic shape, images of patients were classified into three types: AP, RP, and NP. Subsequently, representative images were selected for each type. The fixation device used in the fusion model was a pedicle screw and a spinal rod of a general type. PEEK was used as the cage material, and the cage shape was varied by using three different cage angles: 0°, 4°, and 8°. Spinal mobility: The pelvic type with the highest range of motion (ROM) for the spine was the NP type; the AP type had the highest LL. Under a combination load, the NP type exhibited the highest lumbar flexibility (LF), which was 2.46° lower on average compared to the case where a pure moment was applied. Equivalent stress on the spinal fixation device: The equivalent stress acting on the vertebrae was lowest when cage 0 was used for the NP and AP type. For the RP type, the lowest equivalent stress on the vertebrae was observed when cage 4 was used. Finally, for the L5 upper endplate, the stress did not vary significantly for a given type of cage. In conclusion, there was no significant difference in ROM according to cage angle, and the highest ROM, LL and LF were shown in the pelvic shape of NP type. However, when comparing the results with other pelvic types, it was not possible to confirm that LF is completely dependent on LL and ROM.

13.
Bioengineering (Basel) ; 9(10)2022 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-36290487

RESUMO

Most studies on the ossification of the posterior longitudinal ligament (OPLL) using the finite element method were conducted in the neutral state, and the resulting decompression was judged to be good. As these studies do not reflect the actual behavior of the cervical spine, this study conducted an analysis in the neutral state and a biomechanical analysis during flexion and extension behaviors. After validation via the construction of an intact cervical spine model, the focal OPLL model was inserted into the C4-C5 segment and a simulation was performed. The neutral state was shown by applying a fixed condition to the lower part of the T1 and Y-axis fixed condition of the spinal cord and simulating spinal cord compression with OPLL. For flexion and extension simulation, a ±30-degree displacement was additionally applied to the top of the C2 dens. Accordingly, it was confirmed that spinal cord decompression did not work well during the flexion and extension behaviors, but rather increased. Thus, if patients with focal OPLL inevitably need to undergo posterior decompression, additional surgery using an anterior approach should be considered.

14.
Front Bioeng Biotechnol ; 10: 969636, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36704311

RESUMO

This study replicated the behavior of intraorbital tissue in patients with thyroid eye disease (TED) based on finite element analysis for general orbital decompression risk evaluation in thyroid eye disease patients. The orbit and intraorbital tissues of thyroid eye disease patients who underwent orbital decompression were modeled as finite element models. The stress was examined at specific locations of the removed orbital wall of a thyroid eye disease patient with undergone orbital decompression, and its variation was analyzed as a function of the shape and dimension (to be removed). As a result, in orbital decompression surgery which removes the orbital wall in a rectangular shape, the stress at the orbital wall decreased as the width and depth of the removed orbital wall increased. In addition, in the case of orbital decompression, it can be seen that the chamfered model compared to the non-chamfered model (a form of general orbital decompression) have the stress reduction rate from 11.08% to 97.88%. It is inferred that if orbital decompression surgery considering the chamfered model is performed on an actual thyroid eye disease patient, it is expected that the damage to the extraocular muscle caused by the removed orbital wall will be reduced.

16.
Sci Rep ; 10(1): 7357, 2020 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-32355303

RESUMO

It is now common to perform the Nuss procedure as a surgical treatment for pectus excavatum. As several types of detailed surgical methods exist as part of the Nuss procedure, studies are currently being conducted to verify their relative superiority via computerized biomechanical methods. However, no studies have considered the influence of sternoclavicular joints on the simulations of the Nuss procedure. Accordingly, this study aims to demonstrate the influence of these joints by comparing the clinical data with the finite element analysis data. Scenarios were set by classifying the movement of the joints based on the constraints of translation and rotation in the coordinate plane. The analyses were performed by applying the set scenarios to the constructed finite element model of a chest wall. The sternal displacement, Haller index, and equivalent stress were obtained from the analysis, and the data were compared with the data of the postoperative patient. When the translation of the anterior direction on the chest wall was constrained, the result obtained thereof was found to be similar to those obtained in the actual surgery. It is suggested that more accurate results can be obtained if the influence of the sternoclavicular joints is considered.


Assuntos
Tórax em Funil/cirurgia , Articulação Esternoclavicular/cirurgia , Análise de Elementos Finitos , Humanos , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Período Pós-Operatório , Esterno/cirurgia , Resultado do Tratamento
17.
J Med Internet Res ; 22(5): e16084, 2020 05 05.
Artigo em Inglês | MEDLINE | ID: mdl-32369034

RESUMO

BACKGROUND: Prognostic genes or gene signatures have been widely used to predict patient survival and aid in making decisions pertaining to therapeutic actions. Although some web-based survival analysis tools have been developed, they have several limitations. OBJECTIVE: Taking these limitations into account, we developed ESurv (Easy, Effective, and Excellent Survival analysis tool), a web-based tool that can perform advanced survival analyses using user-derived data or data from The Cancer Genome Atlas (TCGA). Users can conduct univariate analyses and grouped variable selections using multiomics data from TCGA. METHODS: We used R to code survival analyses based on multiomics data from TCGA. To perform these analyses, we excluded patients and genes that had insufficient information. Clinical variables were classified as 0 and 1 when there were two categories (for example, chemotherapy: no or yes), and dummy variables were used where features had 3 or more outcomes (for example, with respect to laterality: right, left, or bilateral). RESULTS: Through univariate analyses, ESurv can identify the prognostic significance for single genes using the survival curve (median or optimal cutoff), area under the curve (AUC) with C statistics, and receiver operating characteristics (ROC). Users can obtain prognostic variable signatures based on multiomics data from clinical variables or grouped variable selections (lasso, elastic net regularization, and network-regularized high-dimensional Cox-regression) and select the same outputs as above. In addition, users can create custom gene signatures for specific cancers using various genes of interest. One of the most important functions of ESurv is that users can perform all survival analyses using their own data. CONCLUSIONS: Using advanced statistical techniques suitable for high-dimensional data, including genetic data, and integrated survival analysis, ESurv overcomes the limitations of previous web-based tools and will help biomedical researchers easily perform complex survival analyses.


Assuntos
Neoplasias/genética , Análise de Sobrevida , Humanos , Internet , Neoplasias/mortalidade , Prognóstico
18.
Oncol Lett ; 17(5): 4614-4620, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30944650

RESUMO

With the growing requirement for novel prognostic biomarkers for pancreatic cancer, many studies have focused on clinical and/or genomic variables. Although many studies have been performed, carbohydrate antigen 19-9 is the only biomarker in clinical use. Therefore, the present study examined whether γ-secretase genes, including presenilin (PSEN), nicastrin (NCSTN), presenilin enhancer protein 2 (PSENEN), and anterior pharynx-defective 1 (APH1-), could serve as prognostic factors for pancreatic cancer. The cohorts selected included >100 pancreatic cancer patients. Patient data were downloaded from The Cancer Genome Atlas (TCGA) and Gene Expression Omnibus (GSE21501). The prognostic roles of the γ-secretase genes were analyzed by several survival analysis methods. Among the γ-secretase genes, the prognosis tended to be worse in the 2 cohorts with increasing expression of PSEN1, APH1A, and PSENEN, while the remaining genes were the opposite in the 2 cohorts. Notably, although the patient characteristics were quite different, APH1A was statistically significantly associated with prognosis in the 2 cohorts. The hazard ratio of APH1A for overall survival was 1.598 (TCGA) and 2.724 (GSE21501). These results contribute to the study of γ-secretase in pancreatic cancer. We believe that γ-secretase, particularly APH1A, will be a new prognostic biomarker for pancreatic cancer.

19.
PLoS One ; 13(8): e0201801, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30114271

RESUMO

PURPOSE: Spinopelvic fixations involving the S2-alar-iliac (S2AI) and iliac screws are commonly used in various spinal fusion surgeries. This study aimed to compare the biomechanical characteristics, specifically the risk of screw and adjacent bone failures of S2AI screw fixation with those of iliac screw fixation using a finite element analysis (FEA). METHODS: A three-dimensional finite element (FE) model of a healthy spinopelvis was generated. The pedicle screws were placed on the L3-S1 with three different lengths of the S2AI and iliac screws (60 mm, 75 mm, and 90 mm). In particular, two types of the S2AI screw, 15°- and 30°-angled polyaxial screw, were adopted. Physiological loads, such as a combination of compression, torsion, and flexion/extension loads, were applied to the spinopelvic FE model, and the stress distribution as well as the maximum von Mises equivalent stress values were calculated. RESULTS: For the iliac screw, the highest stress on the screw was observed with the 75-mm screw, rather than the 60-mm screw. The bones around the iliac screw indicated that the maximum equivalent stress decreased as the screw length increased. For the S2AI screw, the lowest stress was observed in the 90-mm screw length with a 30° head angle. The bones around the S2AI screw indicated that the lowest stress was observed in the 90-mm screw length and a 15° head angle. CONCLUSIONS: It was found that the S2AI screw, rather than the iliac screw, reduced the risk of implant failure for the spinopelvic fixation technique, and the 90-mm screw length with a 15° head angle for the S2AI screw could be biomechanically advantageous.


Assuntos
Parafusos Ósseos , Fixação Interna de Fraturas/instrumentação , Pelve/cirurgia , Falha de Prótese , Coluna Vertebral/cirurgia , Adulto , Fenômenos Biomecânicos , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Masculino , Modelos Anatômicos , Pelve/diagnóstico por imagem , Fatores de Risco , Coluna Vertebral/diagnóstico por imagem , Estresse Mecânico , Tomografia Computadorizada por Raios X , Torção Mecânica
20.
Oncotarget ; 8(44): 77515-77526, 2017 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-29100405

RESUMO

Accurate prediction of prognosis is critical for therapeutic decisions regarding cancer patients. Many previously developed prognostic scoring systems have limitations in reflecting recent progress in the field of cancer biology such as microarray, next-generation sequencing, and signaling pathways. To develop a new prognostic scoring system for cancer patients, we used mRNA expression and clinical data in various independent breast cancer cohorts (n=1214) from the Molecular Taxonomy of Breast Cancer International Consortium (METABRIC) and Gene Expression Omnibus (GEO). A new prognostic score that reflects gene network inherent in genomic big data was calculated using Network-Regularized high-dimensional Cox-regression (Net-score). We compared its discriminatory power with those of two previously used statistical methods: stepwise variable selection via univariate Cox regression (Uni-score) and Cox regression via Elastic net (Enet-score). The Net scoring system showed better discriminatory power in prediction of disease-specific survival (DSS) than other statistical methods (p=0 in METABRIC training cohort, p=0.000331, 4.58e-06 in two METABRIC validation cohorts) when accuracy was examined by log-rank test. Notably, comparison of C-index and AUC values in receiver operating characteristic analysis at 5 years showed fewer differences between training and validation cohorts with the Net scoring system than other statistical methods, suggesting minimal overfitting. The Net-based scoring system also successfully predicted prognosis in various independent GEO cohorts with high discriminatory power. In conclusion, the Net-based scoring system showed better discriminative power than previous statistical methods in prognostic prediction for breast cancer patients. This new system will mark a new era in prognosis prediction for cancer patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...