1.
Micromachines (Basel) ; 12(4)2021 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-33923849

RESUMO

Piezoresistive tactile sensors made using nanocomposite polymeric materials have been shown to possess good flexibility, electrical performance, and sensitivity. However, the sensing performance, especially in the low-pressure range, can be significantly improved by enabling uniform dispersion of the filler material and utilization of effective structural designs that improve the tactile sensing performance. In this study, a novel flexible piezoresistive tactile sensor with a grid-type microstructure was fabricated using polymer composites comprising multi-walled carbon nanotubes (MWCNTs) as the conductive filler and polydimethylsiloxane (PDMS) as the polymeric matrix. The research focused on improving the tactile sensor performance by enabling uniform dispersion of filler material and optimizing sensor design and structure. The doping weight ratio of MWCNTs in PDMS varied from 1 wt.% to 10 wt.% using the same grid structure-sensing layer (line width, line spacing, and thickness of 1 mm). The sensor with a 7 wt.% doping ratio had the most stable performance, with an observed sensitivity of 6.821 kPa-1 in the lower pressure range of 10-20 kPa and 0.029 kPa-1 in the saturation range of 30-200 kPa. Furthermore, the dimensions of the grid structure were optimized and the relationship between grid structure, sensitivity, and sensing range was correlated. The equation between pressure and resistance output was derived to validate the principle of piezoresistance. For the grid structure, dimensions with line width, line spacing, and thickness of 1, 1, and 0.5 mm were shown to have the most stable and improved response. The observed sensitivity was 0.2704 kPa-1 in the lower pressure range of 50-130 kPa and 0.0968 kPa-1 in the saturation range of 140-200 kPa. The piezoresistive response, which was mainly related to the quantum tunneling effect, can be optimized based on the dopant concentration and the grid microstructure. Furthermore, the tactile sensor showed a repeatable response, and the accuracy was not affected by temperature changes in the range of 10 to 40 °C and humidity variations from 50 to 80%. The maximum error fluctuation was about 5.6% with a response delay time of about 1.6 ms when cyclic loading tests were performed under a normal force of 1 N for 10,200 cycles. Consequently, the proposed tactile sensor shows practical feasibility for a wide range of wearable technologies and robotic applications such as touch detection and grasping.

2.
Materials (Basel) ; 11(2)2018 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-29364832

RESUMO

By the conventional solid state reaction method, a small amount of lithium fluoride (LiF) was used as the sintering promoter to improve the sintering and piezoelectric characteristics of (Ba0.95Ca0.05)(Ti0.93Sn0.07)O3 (BCTS) lead-free piezoceramic sheets. Using X-ray diffraction (XRD) and a scanning electron microscope (SEM), the inferences of the crystalline and surface microstructures were obtained and analyzed. Then, the impedance analyzer and d33-meter were used to measure the dielectric and piezoelectric characteristics. In this study, the optimum sintering temperature of the BCTS sheets decreased from 1450 °C to 1390 °C due to LiF doping. For the 0.07 wt % LiF-doped BCTS sheets sintered at 1390 °C, the piezoelectric constant (d33) is 413 pC/N, the electric-mechanical coupling coefficient (kp) is 47.5%, the dielectric loss (tan δ) is 3.9%, and the dielectric constant (εr) is 8100, which are all close to or even better than that of the pure undoped BCTS ceramics. The Curie temperature also improved, from 85 °C for pure BCTS to 140 °C for BCTS-0.07 LiF sheets. Furthermore, by using the vibration system and fixing 1.5 g tip mass at the end of the sheets, as the vibration frequency is 20 Hz, the proposed piezoelectric ceramic sheets also reveal a good energy harvesting performance at the maximum output peak voltage of 4.6 V, which is large enough and can be applied in modern low-power electronic products.

3.
Biosens Bioelectron ; 84: 126-32, 2016 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-26777732

RESUMO

An ultrasensitive and real-time impedance based immunosensor has been fabricated for the quantitative detection of Galectin-1 (Gal-1) protein, a biomarker for the onset of multiple oncological conditions, especially bladder cancer. The chip consists of a gold annular interdigitated microelectrode array (3×3 format with a sensing area of 200µm) patterned using standard microfabrication processes, with the ability to electrically address each electrode individually. To improve sensitivity and immobilization efficiency, we have utilized nanoprobes (Gal-1 antibodies conjugated to alumina nanoparticles through silane modification) that are trapped on the microelectrode surface using programmable dielectrophoretic manipulations. The limit of detection of the immunosensor for Gal-1 protein is 0.0078mg/ml of T24 (Grade III) cell lysate in phosphate buffered saline, artificial urine and human urine samples. The normalized impedance variations show a linear dependence on the concentration of cell lysate present while specificity is demonstrated by comparing the immunosensor response for two different grades of bladder cancer cell lysates. We have also designed a portable impedance analyzing device to connect the immunosensor for regular checkup in point of care testing with the ability to transfer data over the internet using a personal computer. We believe that this diagnostic system would allow for improved public health monitoring and aid in early cancer diagnosis.


Assuntos
Técnicas Biossensoriais/instrumentação , Galectina 1/urina , Testes Imediatos , Neoplasias da Bexiga Urinária/urina , Óxido de Alumínio/química , Anticorpos Imobilizados/química , Linhagem Celular Tumoral , Impedância Elétrica , Desenho de Equipamento , Humanos , Imunoensaio/instrumentação , Limite de Detecção , Microeletrodos , Nanopartículas/química , Neoplasias da Bexiga Urinária/diagnóstico
SELEÇÃO DE REFERÊNCIAS