Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 14(21)2021 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-34772250

RESUMO

This study analyzed the influence of carbon nanotubes (CNTs) on the carbonation conductive cementitious composites. Two powder types of CNT, multi-walled and single-wall CNTs, were employed to give the cement mortar the conductivity, and four tests including the accelerated carbonation, compressive and flexural strength, electrical resistance, and porosity tests were carried out. To intentionally accelerate the carbonation, the prismatic specimens of conductive cement composites were fabricated and stored in the controlled environmental chamber at a constant temperature of 20 ± 2 °C, constant relative humidity of 60 ± 5%, and carbon dioxide (CO2) concentration of 5% for 12 weeks. It was observed that carbonation resulted in only chemical damage so that there was no change in the electrical resistance value of conductive cementitious mortar that had undergone a carbonation attack.

2.
Materials (Basel) ; 14(16)2021 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-34442906

RESUMO

To date, a method of attaching a FRP (fiber-reinforced polymer) to concrete members with epoxy has been widely applied to increase the strength of the member. However, there are cases in which the adhesion of the epoxy deteriorates over time and the reinforcing effect of the FRP is gradually lost. Therefore, monitoring whether or not the reinforcing effect is properly maintained is needed in order to prevent a decrease in the structural performance of the member improved by FRP reinforcement. In this regard, this study examines FRP with OF (optical fiber) sensors to monitor the reinforcing effect of FRP in concrete structural members. In particular, this paper seeks to determine an appropriate adhesion length when FBG (fiber Bragg grating) based OF sensors are externally bonded to FRP strips with epoxy resin. To this end, a tensile test was carried out to evaluate the sensing performance according to the adhesion length. In addition, an analytical approach was performed and the result were compared with test result. The results of the experimental and analytical studies showed that the strain generated in the FRP is sufficiently transferred to the OF if the total adhesion length of it is 40 mm or more in consideration of the error in the epoxy thickness.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...