Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 252
Filtrar
2.
Orbit ; : 1-4, 2022 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-35635143

RESUMO

A 60-year-old female presented with a large, left upper eyelid mass that had rapidly expanded in the 3 months prior to presentation. She had a presumed chalazion excised from the same area 1.5 years ago, but no pathology was investigated. On examination, she had a palpebral mass measuring 4.5 cm x 3.5 cm that abutted the globe with extensive conjunctival involvement. Neuroimaging demonstrated lesions concerning for parotid gland metastases. An incisional biopsy demonstrated synaptophysin-positive small blue cells concerning for neuroendocrine carcinoma. The patient underwent orbital exenteration with parotidectomy and radical neck dissection. The excised mass was found to have distinct neuroendocrine carcinoma cells intermingled with sebaceous carcinoma cells, a combination not previously reported.

3.
Am J Otolaryngol ; 43(1): 103229, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34537506

RESUMO

PURPOSE: There are a variety of implant materials available for orbital floor fracture repair. Implant selection is guided by surgeon experience, availability, and patient specific needs. The purpose of this study is to describe a "wraparound" technique for nylon foil implant placement for large, isolated floor fractures that provides excellent results with low incidence of enophthalmos or other complications. MATERIALS AND METHODS: A retrospective chart review from 2012 to 2020 was conducted in patients who underwent isolated orbital floor fracture repair with the use of the "wraparound" nylon foil implant. The surgical technique is described. Preoperative CT scans were assessed, and the patients were divided into groups based on the size of the floor fracture. Postoperative data was collected including Hertel measurements and complications related to the implant. RESULTS: There were eighty patients who underwent orbital floor fracture repair with the described technique and had adequate follow-up. There were 18 (22.5%) small-sized fractures, 32 (40%) medium-sized fractures, and 30 (37.5%) large-sized fractures in the study group. One patient (3.33%) in the large fracture group had clinically significant enophthalmos of 2 mm postoperatively. There were no other patients with clinically significant enophthalmos. There were no instances of any complications related to the implant, and no patients required implant removal. CONCLUSIONS: The "wraparound" technique for a nylon foil implant provides excellent results for isolated orbital floor fractures. It provides more support and stability than traditional nylon implants for larger fractures and has minimal complication rates.


Assuntos
Órbita/lesões , Fraturas Orbitárias/cirurgia , Implantes Orbitários , Procedimentos de Cirurgia Plástica/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Enoftalmia/epidemiologia , Enoftalmia/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nylons , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Procedimentos de Cirurgia Plástica/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
4.
Ophthalmic Plast Reconstr Surg ; 38(1): 73-78, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34085994

RESUMO

PURPOSE: To present a protocol for audiologic monitoring in the setting of teprotumumab treatment of thyroid eye disease, motivated by 4 cases of significant hearing loss, and review the relevant literature. METHODS: Cases of hearing loss in the setting of teprotumumab were retrospectively elicited as part of a multi-institutional focus group, including oculoplastic surgeons, a neurotologist and an endocrinologist. A literature review was performed. RESULTS: An aggregate of 4 cases of teprotumumab-associated hearing loss documented by formal audiologic testing were identified among 3 clinicians who had treated 28 patients. CONCLUSIONS: Teprotumumab may cause a spectrum of potentially irreversible hearing loss ranging from mild to severe, likely resulting from the inhibition of the insulin-like growth factor-1 and the insulin-like growth factor-1 receptor pathway. Due to the novelty of teprotumumab and the lack of a comprehensive understanding of its effect on hearing, the authors endorse prospective investigations of hearing loss in the setting of teprotumumab treatment. Until the results of such studies are available, the authors think it prudent to adopt a surveillance protocol to include an audiogram and tympanometry before, during and after infusion, and when prompted by new symptoms of hearing dysfunction.


Assuntos
Anticorpos Monoclonais Humanizados , Perda Auditiva , Perda Auditiva/induzido quimicamente , Perda Auditiva/diagnóstico , Humanos , Estudos Prospectivos , Estudos Retrospectivos
6.
Sci Rep ; 11(1): 10564, 2021 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-34011936

RESUMO

We have studied flux-pinning effects of [Formula: see text] superconductor by doping (Fe, Ti) particles of which radius is 163 nm on average. 5 wt.% (Fe, Ti) doped [Formula: see text] among the specimens showed the best field dependence of magnetization and 25 wt.% one did the worst at 5 K. The difference of field dependence of magnetization of the two specimens increased as temperature increased. Here we show experimental results of (Fe, Ti) particle-doped [Formula: see text] specimens according to dopant level and the causes of the behaviors. Flux-pinning effect of volume defects-doped superconductor was modeled in ideal state and relative equations were derived. During the study, we had to divide M-H curve of volume defect-dominating superconductor as three discreet regions for analyzing flux-pinning effects, which are diamagnetic increase region after [Formula: see text], [Formula: see text] region, and diamagnetic decrease region. As a result, flux-pinning effects of volume defects decreased as dopant level increased over the optimal dopant level, which was caused by decrease of flux-pinning limit of a volume defect. And similar behaviors are obtained as dopant level decreased below the optimal dopant level, which was caused by the decreased number of volume defects. Comparing the model with experimental results, deviations increased as dopant level increased over the optimal dopant level, whereas the two was well matched on less dopant level. The behavior is considered to be caused by the segregation of the volume defects. On the other hand, the cause that diamagnetic properties of over-doped [Formula: see text] specimens dramatically decreased as temperature increased was the double decreases of flux-pinning limit of a volume defect and the segregation effect, which are caused by over-doping and temperature increase.

8.
Am J Otolaryngol ; 42(2): 102879, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33429179

RESUMO

PURPOSE: Diplopia and ocular motility restriction following orbital fracture repair are common complications. The reported rates in the literature differ greatly, in part due to varying definitions of diplopia and methods of measurement. The purpose of this study is to describe a practical and efficient in-office method for examining ocular motility and diplopia in orbital trauma patients and to report the outcomes in a series of patients who underwent orbital floor fracture repair. MATERIALS AND METHODS: A retrospective chart review from 2012 to 2019 was conducted in patients who underwent isolated orbital floor fracture repair within 3 weeks of trauma. All patients had examinations to assess extraocular motility and subjective diplopia using the described techniques. RESULTS: Ninety-three patients underwent orbital floor fracture repair and had adequate follow-up. Preoperatively, 71 (76%) patients had some restriction in motility and 59 (63%) patients complained of diplopia. Postoperatively, only 1 patient (1.09%) had clinically significant diplopia. Five (5.4%) additional patients demonstrated mild restriction in supraduction upon detailed ophthalmic examination that was not discovered upon subjective history. No patients had worsening of diplopia or motility after surgery. CONCLUSIONS: Diplopia and motility restriction following orbital fracture repair can be a persistent problem for some patients. It is important to perform a careful ophthalmic examination to detect motility deficits and diplopia that can be significant to the patient. The true rate of restriction and diplopia may be higher using detailed ophthalmic diagnostic techniques compared to subjective patient history.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Diplopia/diagnóstico , Diplopia/etiologia , Transtornos da Motilidade Ocular/diagnóstico , Transtornos da Motilidade Ocular/etiologia , Procedimentos Cirúrgicos Oftalmológicos/efeitos adversos , Procedimentos Cirúrgicos Oftalmológicos/métodos , Fraturas Orbitárias/cirurgia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
9.
Orbit ; 40(3): 222-227, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32460574

RESUMO

Purpose: To compare the efficacy of the vertical lid split (VLS) to the standard lateral canthotomy and cantholysis (LC/C) for orbital compartment syndrome (OCS) in the cadaveric model.Methods: Simulated OCS was achieved in seven fresh frozen cadaveric orbits. Orbital pressure (OP) was monitored in one control orbit and six interventional orbits. Initial OP was recorded before three right orbits underwent lateral canthotomy with superior and inferior cantholysis, and three left orbits underwent vertical lid split of the upper and lower eyelids. In all 7 orbits, OP was recorded for a total of 16 min. The main outcome measure was the amount of OP reduction at timed intervals.Results: Beginning OP in the control orbit was 109 mmHg, and average initial OP of the LC/C and VLS orbits were 90 and 103 mmHg, respectively. The control orbit maintained high OP without intervention. One minute after LC/C, OP decreased an average of 58.7 mmHg (65.2%; range 48-65 mmHg). One minute following VLS, OP decreased an average of 63 mmHg (61.0%; range 39-102 mmHg). At 16 min, OP reduction in the LC/C orbits averaged 65.3 mmHg (72.6%; range 56-71 mmHg), and OP reduction in the VLS orbits averaged 78 mmHg (75.5%; range 54-121 mmHg). Both interventions produced a comparable reduction in OP.Conclusions: Vertical lid split was found to be as effective as LC/C in reducing OP. The technical simplicity of the VLS lends itself well to utilization by physicians who are unfamiliar with eyelid surgery.


Assuntos
Síndromes Compartimentais , Órbita , Síndromes Compartimentais/cirurgia , Pálpebras/cirurgia , Humanos , Pressão Intraocular , Órbita/cirurgia
10.
Sci Rep ; 10(1): 15445, 2020 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-32963275

RESUMO

We investigated the relationship between the prognostic importance of anatomic tumour burden and subtypes of breast cancer using data from the Korean Breast Cancer Registry Database. In HR+/HER2+ and HR-/HER2-tumours, an increase in T stage profoundly increased the hazard of death, while the presence of lymph node metastasis was more important in HR+/HER2+ and HR-/HER2+ tumours among 131,178 patients with stage I-III breast cancer. The patterns of increasing mortality risk and tumour growth (per centimetre) and metastatic nodes (per node) were examined in 67,038 patients with a tumour diameter ≤ 7 cm and < 8 metastatic nodes. HR+/HER2- and HR-/HER2- tumours showed a persistent increase in mortality risk with an increase in tumour diameter, while the effect was modest in HER2+ tumours. Conversely, an increased number of metastatic nodes was accompanied by a persistently increased risk in HR-/HER2+ tumours, while the effect was minimal for HR-/HER2- tumours with > 3 or 4 nodes. The interactions between the prognostic significance of anatomic tumour burden and subtypes were significant. The prognostic relevance of the anatomic tumour burden was non-linear and highly dependent on the subtypes of breast cancer.


Assuntos
Neoplasias da Mama/classificação , Neoplasias da Mama/patologia , Receptor ErbB-2/metabolismo , Receptores de Estrogênio/metabolismo , Receptores de Progesterona/metabolismo , Carga Tumoral , Adolescente , Adulto , Idoso , Biomarcadores Tumorais/metabolismo , Neoplasias da Mama/metabolismo , Neoplasias da Mama/terapia , Terapia Combinada , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Metástase Neoplásica , Prognóstico , Taxa de Sobrevida , Adulto Jovem
11.
Sci Rep ; 10(1): 5416, 2020 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-32214124

RESUMO

We studied a method of measuring upper critical field (Hc2) of a superconductor based on a width of ΔH = ΔB region, which appears in a superconductor that volume defects are many and dominant. Here we show basic concepts and details of the method. Although Hc2 of a superconductor is fixed according to a kind of superconductor, it is difficult to measure Hc2 experimentally. Thus, results are different depending on experimental conditions. Hc2 was otained by a theory on a width of ΔH = ΔB region, which is that pinned fluxes at volume defects are picked out and move into an inside of the superconductor when the distance between pinned fluxes is the same as that at Hc2 of the superconductor. Hc2 of MgB2 obtained by the method was 65.4 Tesla at 0 K, which is quite same as that of Ginzburg-Landau theory. The reason that Hc2 obtained by the method is closer to ultimate Hc2 is based on that Fpinning/Fpickout is more than 4 when pinned fluxes at volume defects of 163 nm radius are depinned, which means that the Hc2 is less sensitive to fluctuation. The method will help to find the ultimate Hc2 of volume defect-dominating superconductors.

12.
Ophthalmic Plast Reconstr Surg ; 36(1): 34-37, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31567912

RESUMO

PURPOSE: To assess the recurrence rate of involutional entropion in patients treated with a combined approach including a modified Bick procedure, excision of preseptal orbicularis muscle, and conservative resection of prolapsed orbital fat. METHODS: A retrospective chart review of patients undergoing repair of involutional entropion with the combined procedure including orbital fat resection and a second group with standard entropion repair without orbital fat resection was performed. Only patients with follow-up greater than 6 months were included in the study. RESULTS: Seventy eyelids of 54 patients met all inclusion criteria for the combined procedure group over a 9-year period from 2008 to 2016. Average follow-up was 46.9 months. There was a documented recurrence of entropion in 1 eyelid during the follow-up period (1.4%). The remaining 69 cases had successful subjective and objective results without need for any additional procedures. In the group undergoing entropion repair without fat resection, 22 eyelids of 19 patients had the required follow-up period with a recurrence rate of 4.5% (p > 0.05). CONCLUSIONS: The authors demonstrate good surgical success with a combined approach of a modified Bick procedure, preseptal orbicularis excision, and conservative orbital fat resection. Conservative fat resection during entropion repair was found to be safe, and the combined procedure was found to be effective with a rate of recurrent entropion of 1.4% on extended follow-up.The authors propose that orbital fat prolapse contributes to the mechanics of involutional entropion and that conservative orbital fat resection during surgical repair of entropion can be done safely, resulting in low recurrence rates.


Assuntos
Blefaroplastia , Entrópio , Entrópio/cirurgia , Seguimentos , Humanos , Prolapso , Recidiva , Estudos Retrospectivos
13.
Am J Otolaryngol ; 40(4): 564-566, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31109804

RESUMO

PURPOSE: The safety profile of the transcutaneous medial canthal incision for access to the medial orbit is assessed with a focus on the risk of post-operative iatrogenic epiphora. METHODS: A retrospective chart review of patients undergoing medial orbitotomy via the transcutaneous medial canthal incision was performed. Patients with a minimum of 3 months of follow-up were included and post-operative complications were assessed and characterized. RESULTS: One-hundred-fifty patients were included in the study. A total of 4 complications were identified, including one each of the following: nasolacrimal duct obstruction, hypertrophic scar, suture granuloma and soft tissue infection. Only the nasolacrimal duct obstruction required surgical intervention. DISCUSSION: Access to the medial orbit has been achieved through a variety of approaches, each with their own benefits and risk profile. The transcaruncular approach has increased in usage as a means to avoid a visible cutaneous scar and decrease the risk of iatrogenic epiphora, however, there are specific patients who may have relative contraindications to this approach. The current study demonstrates the low risk profile of the transcutaneous medial canthal incision, specifically the minimal risk of iatrogenic damage to the nasolacrimal outflow system. This approach is another useful tool which orbit surgeons should be familiar with to offer as an option to patients requiring medial orbitotomy.


Assuntos
Doença Iatrogênica/prevenção & controle , Doenças do Aparelho Lacrimal/prevenção & controle , Aparelho Lacrimal/cirurgia , Procedimentos Cirúrgicos Oftalmológicos/métodos , Órbita/cirurgia , Osteotomia/métodos , Complicações Pós-Operatórias/prevenção & controle , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Risco , Adulto Jovem
14.
Am J Otolaryngol ; 40(4): 509-511, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30987775

RESUMO

PURPOSE: To examine the incidence of intracapsular hemorrhage in orbital fracture repair with non-fixated nylon sheet implants. METHODS: A retrospective chart review of 227 patients presenting from January 2013 to December 2016 for orbital fracture repair with nylon sheet implants. RESULTS: Of the 331 orbital fractures repaired over 4 years, a total of 227 met inclusion criteria. The average implant thickness was 0.38 mm and no implants were fixated. Four total implants (1.8%) were removed due to complications; one each secondary to exploration for ongoing postoperative diplopia, immediate post-operative orbital hemorrhage, a cystic mass anterior to the implant, and pain. There were no cases of intracapsular hemorrhage nor infection for any of the 227 patients over 4 years. CONCLUSIONS: To the authors knowledge, this represents the largest case series to date to assess the rate of intracapsular hemorrhage in non-fixated nylon sheet orbital implants. In the 227 cases reviewed over a 4-year period, there were no cases of intracapsular hemorrhage. This suggests a much lower complication rate than previously reported. PRéCIS: A case series of 227 patients who underwent orbital fracture repair with non-fixated nylon sheet implants.


Assuntos
Hemorragia Ocular/epidemiologia , Nylons/efeitos adversos , Fraturas Orbitárias/cirurgia , Implantes Orbitários/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Diplopia/epidemiologia , Diplopia/etiologia , Hemorragia Ocular/etiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
15.
Ophthalmic Plast Reconstr Surg ; 35(4): 403-406, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30908466

RESUMO

PURPOSE: To evaluate the efficacy in degree of ptosis correction achieved by single suture Müeller muscle conjunctival resection (ssMMCR) when compared with that of traditional MMCR. METHODS: A retrospective chart analysis of patients who underwent either ssMMCR or traditional MMCR at 2 institutions. Single suture MMCR was performed after using a ptosis clamp to imbricate conjunctiva and Müeller muscle. Margin-to-reflex distance 1 was measured pre- and postoperatively, and the change in margin-to-reflex distance 1 was analyzed for both groups. Patients were monitored in follow up for postoperative complications including lagophthalmos, corneal abrasions, and change in visual acuity. Statistical analysis was performed using the Microsoft Excel and Stata software programs. RESULTS: Twenty-seven and 30 patients underwent single suture and traditional MMCR, respectively. The ssMMCR and MMCR groups were followed postoperatively for approximately 4.2 and 9.7 months, respectively and the average margin-to-reflex distance 1 increased by 2.93 mm and 2.81 mm, respectively. Notably, there was no statistically significant difference in the means identified by t test. Of the 94 eyelid surgeries evaluated, 1 ssMMCR and 3 MMCR eyelids required further surgical revision for persistent ptosis, and 1 ssMMCR developed a transient corneal epithelial abrasion. Surgical revisions were rare with both procedures, and patient satisfaction was high. CONCLUSIONS: Single suture MMCR is an efficient and effective method for ptosis repair. It results in comparable outcomes including elevation in margin-to-reflex distance 1, safety profile, and reoperation rates, when compared with traditional MMCR.


Assuntos
Blefaroplastia/métodos , Blefaroptose/cirurgia , Túnica Conjuntiva/cirurgia , Músculos Oculomotores/cirurgia , Técnicas de Sutura/instrumentação , Suturas , Idoso , Idoso de 80 Anos ou mais , Pálpebras/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Retrospectivos , Resultado do Tratamento
16.
Ophthalmic Plast Reconstr Surg ; 35(1): 67-70, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30198963

RESUMO

PURPOSE: The aim of this study was to evaluate the efficacy of the nonporous polyethylene barrier sheet as an alternative for nylon foil (SupraFOIL) implants in repair of orbital fractures. METHODS: This is a prospective, case series using the Stryker 0.4-mm-thick nonporous polyethylene barrier sheet in all patients over the age of 18 years presenting with orbital fractures from December 2014 to June 2015. Patient's age, location of fracture, etiology of injury, presence of preoperative restriction and diplopia, and postoperative diplopia and/or enophthalmos was recorded. Institutional review board approval was received, and consent was obtained from all participants. Patients were followed for at least 6 months when possible. Scanning electron microscopy was used to compare the thickness, surface characteristics, and porosity of the nonporous polyethylene barrier and nylon foil implants. Beam deflection testing was also performed to compare the biomechanical properties of each implant. RESULTS: Forty-six patients who underwent repair of orbital fractures with the nonporous polyethylene barrier sheet were included in this series. Average age was 43.3 years (range: 18-84 years). Twenty-six of 46 patients (56.5%) were males, and 20 (43.4%) were females. The most common causes of injuries were assault (38.3%), falls (25.5%), motor vehicle accident (14.9%), and sports related (10.5%). Twenty of 46 patients (43.4%) had isolated orbital floor, and 2 patients (4.3%) had isolated medial wall fractures. Fifteen patients (32.6%) had combined floor and medial wall fractures involving the inferomedial orbital strut, and 9 (19.6%) had floor fractures associated with zygomaticomaxillary complex or lateral wall fractures. Twenty-eight patients (60.9%) had preoperative diplopia. Timing of surgery was between 3 and 55 days, with the median of 11.5 days. Five of 46 patients (10.8%) had residual diplopia at their 1-week postoperative visit, 4 of those patients' diplopia had resolved at 2 months postoperatively. One patient had residual diplopia at 6-month follow up. Electron microscopy showed that the 0.4-mm nonporous polyethylene barrier implant was thinner (0.33 mm) than expected and thinner than 0.4-mm SupraFOIL (0.38 mm). Scanning electron microscopy exhibited that the surface of the nonporous polyethylene barrier was smooth and nonporous. Beam deflection testing showed that for small forces (<100 mN), the 2 materials behaved nearly identically, but at higher forces, the nonporous polyethylene implant exhibited less stiffness. CONCLUSIONS: The use of nonporous polyethylene barrier sheet implant for orbital fracture repair is a safe and effective alternative to nonporous nylon foil implants. There were no complications and one case of residual diplopia (2.1%) in this case series.


Assuntos
Fixação de Fratura/métodos , Procedimentos Cirúrgicos Oftalmológicos/métodos , Implantes Orbitários , Procedimentos de Cirurgia Plástica/métodos , Polietileno , Implantação de Prótese/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas Orbitárias/diagnóstico , Fraturas Orbitárias/cirurgia , Porosidade , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
17.
Orbit ; 38(4): 318-321, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30388918

RESUMO

Purpose: The anterior vestibule salvaging ('Birdcage') technique may limit orbital implant extrusion following evisceration. Methods: A 10-year retrospective chart review from 2005 to 2015 of individuals who underwent evisceration procedures utilizing the vestibule salvaging technique was performed. Results: A total of 96 patients (61 male; 35 female; average age 64 years; range 17-96 years) underwent evisceration with a technique avoiding anterior scleral relaxing incisions. Three (3.1%) patients had documented extrusion of the silicone implant. Time from evisceration to extrusion ranged from 26 to 372 days. Conclusions: Maintenance of the anterior scleral vestibule during evisceration may decrease extrusion rates after surgery compared with traditional evisceration techniques that utilize anterior relaxing incisions.


Assuntos
Evisceração do Olho , Procedimentos Cirúrgicos Oftalmológicos , Implantes Orbitários , Complicações Pós-Operatórias/prevenção & controle , Esclera/cirurgia , Elastômeros de Silicone , Deiscência da Ferida Operatória/prevenção & controle , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Implantação de Prótese , Estudos Retrospectivos , Adulto Jovem
18.
Am J Otolaryngol ; 39(5): 472-475, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29776684

RESUMO

PURPOSE: To present the results of treating combined lower eyelid laxity, retraction and midface descent secondary to facial nerve weakness with a hybrid surgical procedure. MATERIALS AND METHODS: A retrospective analysis of patients from January 2015 to January 2017 who underwent a hybrid surgical technique for the treatment of corneal exposure secondary to facial nerve paresis with a single surgeon was performed. Age, gender, and presence of exposure symptoms were recorded pre-operatively. Outcomes assessed included improvement of lower eyelid laxity and position, operative complications, and post-operative symptomatic relief. RESULTS: A total of 11 patients underwent unilateral eyelid surgery. All patients had symptomatic relief and good functional outcomes defined as improvement in eyelid laxity, lower eyelid position, and objective corneal exposure. No cases required reoperation during an average follow up of 174.5 days. CONCLUSIONS: Combining portions of a tarsorrhaphy and lateral wedge resection technique is a simple and effective procedure to improve lower eyelid position and limit corneal exposure secondary to facial nerve paresis.


Assuntos
Blefaroplastia/métodos , Doenças Palpebrais/etiologia , Doenças Palpebrais/cirurgia , Doenças do Nervo Facial/complicações , Procedimentos de Cirurgia Plástica/métodos , Adulto , Idoso , Estudos de Coortes , Córnea/fisiopatologia , Estética , Doenças Palpebrais/fisiopatologia , Pálpebras/inervação , Doenças do Nervo Facial/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paresia/complicações , Paresia/diagnóstico , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Resultado do Tratamento
19.
Ophthalmic Plast Reconstr Surg ; 34(4): 387-389, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29356717

RESUMO

PURPOSE: To review physician-based clinical surveys published in Ophthalmic Plastic and Reconstructive Surgery. METHODS: Complementary Ovid and PubMed searches of Ophthalmic Plastic and Reconstructive Surgery journal content were performed for the term "survey." Results were narrowed to studies that specifically addressed physicians' clinical practices. This search resulted in 162 articles, and after dual-investigator independent screening, 13 surveys met inclusion criteria. RESULTS: Of the 13 surveys published from 2007 to January 2017, 6 were published since 2015, showing an increased trend in survey-based publications. Topics included assessing practice patterns regarding eyelid disorders, thyroid eye disease, optic nerve sheath fenestration, anophthalmic socket, and diagnosing lacrimal disorders. Average response rate was 38.7% (range 17.5-60%), with 201 average number of replies (range 72-310). Nine out of 13 surveys included some form of statistical analysis with the remainder presenting data in percentages. CONCLUSIONS: There has been an increased rate of survey-type publications in Ophthalmic Plastic and Reconstructive Surgery over the past 10 years. The low response rate and frequent lack of statistical analysis raise concerns regarding the validity and usefulness of such studies. The authors believe that survey studies can be improved through better standardization and the use of author guidelines. They have made specific recommendations to improve the impact of survey papers in the future.


Assuntos
Pesquisas sobre Atenção à Saúde/tendências , Pesquisa sobre Serviços de Saúde/métodos , Oftalmologia , Publicações Periódicas como Assunto , Procedimentos de Cirurgia Plástica , Editoração/tendências , Cirurgia Plástica , Humanos , Estudos Retrospectivos
20.
Vet Comp Oncol ; 16(2): 239-245, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29266697

RESUMO

Glutamine metabolism is an important metabolic pathway for cancer cell survival, and there is a critical connection between tumour growth and glutamine metabolism. Because of their similarities, canine mammary carcinomas are useful for studying human breast cancer. Accordingly, we investigated the correlations between the expression of glutamine metabolism-related proteins and the pathological features of canine mammary tumours. We performed immunohistochemical and western blot analysis of 39 mammary tumour tissues. In immunohistochemical analysis, the expression of glutaminase 1 (GLS1) in the epithelial region increased according to the histological grade (P < .005). In the stromal region, complex-type tumours displayed significantly higher GLS1 intensity than simple-type tumours. However, glutamate dehydrogenase expression did not show the same tendencies as GLS1. The western blot results were consistent with the immunohistochemical findings. These results suggest that the expression of GLS1 is correlates with clinicopathological factors in canine mammary tumours and shows a similar pattern to human breast cancer.


Assuntos
Doenças do Cão/metabolismo , Glutamato Desidrogenase/metabolismo , Glutaminase/metabolismo , Glutamina/metabolismo , Neoplasias Mamárias Animais/metabolismo , Análise de Variância , Animais , Neoplasias da Mama/metabolismo , Doenças do Cão/patologia , Cães , Feminino , Humanos , Imuno-Histoquímica/veterinária , Neoplasias Mamárias Animais/patologia , República da Coreia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...