Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-32457880

RESUMO

BACKGROUND: To evaluate the lifetime secondary cancer risk (SCR) of stereotactic body radiotherapy (SBRT) using the CyberKnife (CK) M6 system with a lung-optimized treatment (LOT) module for lung cancer patients. METHODS: We retrospectively enrolled 11 lung cancer patients curatively treated with SBRT using the CK M6 robotic radiosurgery system. The planning treatment volume (PTV) and common organs at risk (OARs) for SCR analysis included the spinal cord, total lung, and healthy normal lung tissue (total lung volume - PTV). Schneider's full model was used to calculate SCR according to the concept of organ equivalent dose (OED). RESULTS: CK-LOT-SBRT delivers precisely targeted radiation doses to lung cancers and achieves good PTV coverage and conformal dose distribution, thus posing limited SCR to surrounding tissues. The three OARs had similar risk equivalent dose (RED) values among four different models. However, for the PTV, differences in RED values were observed among the models. The cumulative excess absolute risk (EAR) value for the normal lung, spinal cord, and PTV was 70.47 (per 10,000 person-years). Schneider's Lnt model seemed to overestimate the EAR/lifetime attributable risk (LAR). CONCLUSION: For lung cancer patients treated with CK-LOT optimized with the Monte Carlo algorithm, the SCR might be lower. Younger patients had a greater SCR, although the dose-response relationship seemed be non-linear for the investigated organs, especially with respect to the PTV. Despite the etiological association, the SCR after CK-LOT-SBRT for carcinoma and sarcoma, is low, but not equal to zero. Further research is required to understand and to show the lung SBRT SCR comparisons and differences across different modalities with motion management strategies.

2.
Sci Rep ; 9(1): 9953, 2019 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-31289294

RESUMO

This study was performed to examine the quality of planning and treatment modality using a CyberKnife (CK) robotic radiosurgery system with multileaf collimator (MLC)-based plans and IRIS (variable aperture collimator system)-based plans in relation to the dose-response of secondary cancer risk (SCR) in patients with benign intracranial tumors. The study population consisted of 15 patients with benign intracranial lesions after curative treatment using a CyberKnife M6 robotic radiosurgery system. Each patient had a single tumor with a median volume of 6.43 cm3 (range, 0.33-29.72 cm3). The IRIS-based plan quality and MLC-based plan quality were evaluated by comparing the dosimetric indices, taking into account the planning target volume (PTV) coverage, the conformity index (CI), and the dose gradient (R10% and R50%). The dose-response SCR with sarcoma/carcinoma induction was calculated using the concept of the organ equivalent dose (OED). Analyses of sarcoma/carcinoma induction were performed using excess absolute risk (EAR) and various OED models of dose-response type/lifetime attributable risk (LAR). Moreover, analyses were performed using the BEIR VII model. PTV coverage using both IRIS-based plans and MLC-based plans was identical, although the CI values obtained using the MLC-based plans showed greater statistical significance. In comparison with the IRIS-based plans, the MLC-based plans showed better dose falloff for R10% and R50% evaluation. The estimated difference between Schneider's model and BEIR VII in linear-no-threshold (Lnt) cumulative EAR was about twofold. The average values of LAR/EAR for carcinoma, for the IRIS-based plans, were 25% higher than those for the MLC-based plans using four SCR models; for sarcoma, they were 15% better in Schneider's SCR models. MLC-based plans showed slightly better conformity, dose gradients, and SCR reduction. There was a slight increase in SCR with IRIS-based plans in comparison with MLC-based plans. EAR analyses did not show any significant difference between PTV and brainstem analyses, regardless of the tumor volume. Nevertheless, an increase in target volume led to an increase in the probability of SCR. EAR showed statistically significant differences in the soft tissue according to tumor volume (1-10 cc and ≥10 cc).


Assuntos
Algoritmos , Neoplasias Encefálicas/cirurgia , Segunda Neoplasia Primária/etiologia , Radiocirurgia/efeitos adversos , Planejamento da Radioterapia Assistida por Computador/normas , Medição de Risco/métodos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Adolescente , Adulto , Idoso , Neoplasias Encefálicas/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Segunda Neoplasia Primária/patologia , Prognóstico , Radioterapia de Intensidade Modulada/efeitos adversos , Estudos Retrospectivos , Adulto Jovem
3.
Cancer Manag Res ; 10: 131-141, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29403311

RESUMO

BACKGROUND: Patients treated with radiotherapy are at risk of developing a second cancer during their lifetime, which can directly impact treatment decision-making and patient management. The aim of this study was to qualify and compare the secondary cancer risk (SCR) after intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) in nasopharyngeal carcinoma (NPC) patients. PATIENTS AND METHODS: We analyzed the treatment plans of a cohort of 10 NPC patients originally treated with IMRT or VMAT. Dose distributions in these plans were used to calculate the organ equivalent dose (OED) with Schneider's full model. Analyses were applied to the brain stem, spinal cord, oral cavity, pharynx, parotid glands, lung, mandible, healthy tissue, and planning target volume. RESULTS: We observed that the OED-based risks of SCR were slightly higher for the oral cavity and mandible when VMAT was used. No significant difference was found in terms of the doses to other organs, including the brain stem, parotids, pharynx, submandibular gland, lung, spinal cord, and healthy tissue. In the NPC cohort, the lungs were the organs that were most sensitive to radiation-induced cancer. CONCLUSION: VMAT afforded superior results in terms of organ-at-risk-sparing compared with IMRT. Most OED-based second cancer risks for various organs were similar when VMAT and IMRT were employed, but the risks for the oral cavity and mandible were slightly higher when VMAT was used.

4.
Sci Rep ; 7(1): 13771, 2017 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-29062118

RESUMO

Propensity score matching evaluates the treatment incidence of radiation-induced pneumonitis (RP) and secondary cancer risk (SCR) after intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for breast cancer patients. Of 32 patients treated with IMRT and 58 who received VMAT were propensity matched in a 1:1 ratio. RP and SCR were evaluated as the endpoints of acute and chronic toxicity, respectively. Self-fitted normal tissue complication probability (NTCP) parameter values were used to analyze the risk of RP. SCRs were evaluated using the preferred Schneider's parameterization risk models. The dosimetric parameter of the ipsilateral lung volume receiving 40 Gy (IV40) was selected as the dominant risk factor for the RP NTCP model. The results showed that the risks of RP and NTCP, as well as that of SCR of the ipsilateral lung, were slightly lower than the values in patients treated with VMAT versus IMRT (p ≤ 0.01). However, the organ equivalent dose and excess absolute risk values in the contralateral lung and breast were slightly higher with VMAT than with IMRT (p ≤ 0.05). When compared to IMRT, VMAT is a rational radiotherapy option for breast cancer patients, based on its reduced potential for inducing secondary malignancies and RP complications.


Assuntos
Neoplasias da Mama/radioterapia , Segunda Neoplasia Primária/etiologia , Pontuação de Propensão , Pneumonite por Radiação/epidemiologia , Radioterapia de Intensidade Modulada/efeitos adversos , Adulto , Idoso , Neoplasias da Mama/patologia , Feminino , Seguimentos , Humanos , Incidência , Pessoa de Meia-Idade , Órgãos em Risco/efeitos da radiação , Prognóstico , Pneumonite por Radiação/etiologia , Dosagem Radioterapêutica , Fatores de Risco , Taiwan/epidemiologia
5.
J Appl Clin Med Phys ; 14(4): 4133, 2013 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-23835379

RESUMO

A frameless radiosurgery system is using a set of thermoplastic mask for fixation and stereoscopic X-ray imaging for alignment. The accuracy depends on mask fixation and imaging. Under certain circumstances, the guidance images may contain insufficient bony structures, resulting in lesser accuracy. A virtual isocenter function is designed for such scenarios. In this study, we investigated the immobilization and the indications for using virtual isocenter. Twenty-four arbitrary imaginary treatment targets (ITTs) in phantom were evaluated. The external Localizer with positioner films was used as reference. The alignments by using actual and virtual isocenter in image guidance were compared. The deviation of the alignment after mask removing and then resetting was also checked. The results illustrated that the mean deviation between the alignment by image guidance using actual isocenter (Iso(img)) and the localizer(Iso(loc)) was 2.26 mm ± 1.16 mm (standard deviation, SD), 1.66 mm ± 0.83 mm for using virtual isocenter. The deviation of the alignment by the image guidance using actual isocenter to the localizer before and after mask resetting was 7.02 mm ± 5.8 mm. The deviations before and after mask resetting were insignificant for the target center from skull edge larger than 80 mm on craniocaudal direction. The deviations between the alignment using actual and virtual isocenter in image guidance were not significant if the minimum distance from target center to skull edge was larger or equal to 30 mm. Due to an unacceptable deviation after mask resetting, the image guidance is necessary to improve the accuracy of frameless immobilization. A treatment isocenter less than 30 mm from the skull bone should be an indication for using virtual isocenter to align in image guidance. The virtual isocenter should be set as caudally as possible, and the sella of skull should be the ideal point.


Assuntos
Imobilização/instrumentação , Posicionamento do Paciente/instrumentação , Imagens de Fantasmas , Radiocirurgia/instrumentação , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Humanos , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X
6.
J Radiat Res ; 54(5): 909-18, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23536544

RESUMO

To evaluate the effect of different treatment plans for whole-pelvic irradiation on small-bowel volumes (SBVs) in patients with gynecologic malignancies, 40 patients were enrolled in this study. Computed tomography (CT) simulations were performed, and the small bowel of each patient was outlined manually. Treatment plans with equal-weighted (EW) and non-equal-weighted (NEW) (70% in bilateral directions) techniques of four-field and intensity-modulated radiation therapy (IMRT) were performed. The V10-V100 represented the volume (cm³) at different levels of the prescribed doses (10-100%). The V10-V100 was compared among the different treatment planning techniques, and patients who were suitable for IMRT or NEW were identified. IMRT and NEW significantly reduced the V50-V100 and V40-V60 levels compared with EW, respectively. NEW caused a significant reduction in the V30-V60 levels in patients with a BMI ≥26 kg/m². Patients with IMRT demonstrated lower V70-V100 levels compared with those with NEW. In patients with a BMI ≥26 kg/m² or an age ≥55 years, lower V20-V50 levels were noted using NEW compared with IMRT. Treatment planning with larger weighting in the bilateral directions in four-field radiotherapy reduces the low-dose SBV in patients with gynecologic malignancies, especially in those with a high BMI or the elderly. IMRT effectively reduces high-dose SBV, especially in patients with a low BMI.


Assuntos
Neoplasias dos Genitais Femininos/radioterapia , Intestino Delgado/efeitos da radiação , Órgãos em Risco/efeitos da radiação , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...