Heliyon ; 9(3): e13927, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36845040

RESUMO

Recently, the importance of mechanical facilities in charge of the safety and comfort of occupants in buildings has once again been highlighted in accordance with global social issues such as the spread of COVID-19. In response, various ventilation systems are being developed to improve indoor air quality, and efforts are being made to satisfy the indoor comfort of the occupants. Such advanced facilities allow occupants to secure indoor air quality, while frequent ventilation systems can affect the cooling and heating load in the building, and there is also a problem that it can occupy a relatively large amount of space in the building. This study proposes an integrated, outdoor fan-ventilated cooling device and analyzes its performance and economic efficiency. The EnergyPlus simulation program was used to model two types of systems for comparison: an existing (base) model with a condenser located in the outdoor unit, and a developed model with the condenser integrated within the cooling system. The state of the air passing through the condenser was analyzed prior to comparing the efficiency of the integrated, outdoor fan-ventilated cooling device, followed by an in-depth analysis of the performance and economic efficiency based on total energy consumption. In Case 1, the air passing through the cooling system was approximately 5  °C lower than the base model and showed 11% peak load reduction in comparison to the maximum energy consumption. Additionally, a comparison between regions with different outdoor air temperatures showed an average cost reduction of 16% in Daejeon and Busan City.

2.
Ultrasonography ; 39(1): 60-69, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31786903

RESUMO

PURPOSE: The purpose of this study was to evaluate the ability of contrast-enhanced ultrasonography (CEUS) with microbubbles to detect metastatic lymph nodes (LNs) for treatment planning and prognosis. METHODS: For the metastatic LN model, ground VX2 tumor tissues were injected subcutaneously in 12 rabbits, just below the right hind limb. The rabbits were classified into three groups based on the LN area: group A (n=4, >1.9 cm2 ), group B (n=4, 1-1.9 cm2 ), and group C (n=4, <1 cm2 ). The LNs were monitored on CEUS for 10 seconds after injecting 2.5 mL of microbubbles. The percent area of metastatic LNs was calculated on pathologic images and compared with CEUS images. RESULTS: In group A, the mean percent area of metastasis was 40.7%±19.4%. In all cases of metastasis, round-shaped perfusion defects were clearly observed in CEUS images. The metastatic areas were strongly correlated with pathologic findings. The mean percent area in group B was 21.5%±14.4%. The CEUS findings showed multiple nodular perfusion defects, clearly revealing the metastatic areas. In group B, the CEUS and pathologic findings were concordant for three of the four cases. The mean percent area in group C was 9.1%±6.4%. However, in this group, CEUS only detected a small perfusion defect in one case. CONCLUSION: CEUS has the potential to depict characteristic imaging features of metastatic LNs but still has limitations in early detection.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...