Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Healthc Mater ; : e2400235, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38569198

RESUMO

Cancer immunotherapy by immune checkpoint inhibitors (ICIs) acts on antitumor responses by stimulating the immune system to attack cancer cells. However, this powerful therapy is hampered by its high treatment cost and limited efficacy. Here, it is shown that the development of an antibody-conjugated nanogel (ANGel), consisting of N-isopropylacrylamide-co-acrylic acid and antibody-binding protein (protein A), potentiates the efficacy of two ICI monoclonal antibodies (mAbs) (cytotoxic-T-lymphocyte-associated antigen 4 and programmed death ligand-1 mAbs). Compared with mAb treatment alone, treatment with a bispecific ANGel surface-conjugated with the mAbs significantly decreases both the survival of Michigan Cancer Foundation-7 (MCF-7) and M D Anderson-Metastatic Breast-231 (MDA-MB-231) breast cancer cells in vitro and the burden of 4T1-luciferase-2-derived orthotopic syngeneic tumors in vivo. The bispecific ANGel is also more potent than the conventional treatment at prolonging survival in animals with triple-negative breast cancer. The advantage of the bispecific ANGel over other engineered bispecific antibodies arises not only from the adaptability to link multiple antibodies quickly and easily, but also from the capability to maintain the anticancer effect steadily at subcutaneously delivered tumor site. This finding has an important implication for cancer immunotherapy, opening a new paradigm to treat solid tumors.

2.
Nat Commun ; 14(1): 2263, 2023 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-37081012

RESUMO

As rubber-like elastomers have led to scientific breakthroughs in soft, stretchable characteristics-based wearable, implantable electronic devices or relevant research fields, developments of degradable elastomers with comparable mechanical properties could bring similar technological innovations in transient, bioresorbable electronics or expansion into unexplored areas. Here, we introduce ultra-stretchable, biodegradable elastomers capable of stretching up to ~1600% with outstanding properties in toughness, tear-tolerance, and storage stability, all of which are validated by comprehensive mechanical and biochemical studies. The facile formation of thin films enables the integration of almost any type of electronic device with tunable, suitable adhesive strengths. Conductive elastomers tolerant/sensitive to mechanical deformations highlight possibilities for versatile monitoring/sensing components, particularly the strain-tolerant composites retain high levels of conductivities even under tensile strains of ~550%. Demonstrations of soft electronic grippers and transient, suture-free cardiac jackets could be the cornerstone for sophisticated, multifunctional biodegradable electronics in the fields of soft robots and biomedical implants.


Assuntos
Robótica , Dispositivos Eletrônicos Vestíveis , Elastômeros/química , Eletrônica , Próteses e Implantes
3.
ACS Biomater Sci Eng ; 8(10): 4486-4496, 2022 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-36178141

RESUMO

Stromal cell-derived factor-1 alpha (SDF-1α, CXCL12) mediates the migration of circulating cells to desired sites for tissue development, homeostasis, and regeneration and can be used to promote cardiac regeneration by recruiting stem cells. However, the use of SDF-1α in the injured heart necessitates not only higher binding affinity to its receptor, CXCR4+, but also better robustness against enzymatic degradation than other SDF-1 isoforms. Here, we conduct a screening of SDF-1α analog peptides that were designed by structure-based drug design (SBDD), a type of computer-aided drug design (CADD). We have developed in vitro and in vivo methods that enable us to estimate the effect of peptides on the migration of human mesenchymal stem cells (hMSCs) and cardiac regeneration in acute myocardial infarction (AMI)-induced animals, respectively. We demonstrate that one type of SDF-1α analog peptide, SDP-4, among the four analog peptides preselected by SBDD, is more potent than native SDF-1α for cardiac regeneration in myocardial infarction. It is interesting to note that the migratory effects of SDP-4 determined by a wound healing assay, a Transwell assay, and a 2D migration assay are comparable to those of SDF-1α. These results suggest that in vivo, as well as in vitro, screening of peptides developed by SBDD is a quintessential process to the development of a novel therapeutic compound for cardiac regeneration. Our finding also has an implication that the SDP-4 peptide is an excellent candidate for use in the regeneration of an AMI heart.


Assuntos
Quimiocina CXCL12 , Infarto do Miocárdio , Animais , Movimento Celular , Quimiocina CXCL12/química , Quimiocina CXCL12/farmacologia , Quimiocina CXCL12/uso terapêutico , Desenho de Fármacos , Humanos , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/metabolismo , Peptídeos/farmacologia , Peptídeos/uso terapêutico , Receptores CXCR4/metabolismo , Receptores CXCR4/uso terapêutico
4.
Biomed Mater ; 16(5)2021 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-34181586

RESUMO

The onlay-graft, one of the most difficult graft conditions, is used for diverse clinical conditions, including plastic and dental surgery. The graft should withstand continuous pressure from overlying tissues and have excellent bone formation capability in a limited bone contact situation. We recently developed a 3D printed Kagome-structured polycaprolactone (PCL) scaffold that has a stronger mechanical property. This study evaluated the clinical feasibility of this scaffold for onlay-graft use. The value of the scaffold containing recombinant human bone morphogenetic protein-2 in a hyaluronate-based hydrogel (rhBMP-2/HA) to enhance bone regeneration was also assessed. 3D-printed Kagome-PCL scaffolds alone (n= 12, group I) or loaded with rhBMP-2/HA (n= 12, group II) were grafted using a rat calvarial onlay-graft model. Following sacrifice at 2, 4, and 8 weeks, all 3D-printed Kagome-PCL scaffolds were accurately positioned and firmly integrated to the recipient bone. Micro-computed tomography and histology analyses revealed a constant height of the scaffolds over time in all animals. New bone grew into the scaffolds in both groups, but with greater volume in group II. These results suggest the promising clinical feasibility of the 3D-printed Kagome-PCL scaffold for onlay-graft use and it could substitute the conventional onlay-graft in the plastic and dental reconstructive surgery in the near future.


Assuntos
Proteína Morfogenética Óssea 2 , Ácido Hialurônico , Poliésteres , Impressão Tridimensional , Alicerces Teciduais/química , Fator de Crescimento Transformador beta , Animais , Proteína Morfogenética Óssea 2/química , Proteína Morfogenética Óssea 2/farmacologia , Regeneração Óssea/efeitos dos fármacos , Ácido Hialurônico/química , Ácido Hialurônico/farmacologia , Hidrogéis/química , Hidrogéis/farmacologia , Masculino , Poliésteres/química , Poliésteres/farmacologia , Ratos , Ratos Sprague-Dawley , Proteínas Recombinantes/química , Proteínas Recombinantes/farmacologia , Fator de Crescimento Transformador beta/química , Fator de Crescimento Transformador beta/farmacologia
5.
Mater Sci Eng C Mater Biol Appl ; 98: 949-959, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30813102

RESUMO

In clinical conditions, the reconstructions performed in the complex and three-dimensional bone defects in the craniomaxillofacial (CMF) area are often limited in facial esthetics and jaw function. Furthermore, to regenerate a bone defect in the CMF area, the used scaffold should have unique features such as different mechanical strength or physical property suitable for complex shape and function of the CMF bones. Therefore, a three-dimensional synthetic scaffold with a patient-customized structure and mechanical properties is more suitable for the regeneration. In this study, the customized kagome-structure scaffold with complex morphology was assessed in vivo. The customized 3D kagome-structure model for the defect region was designed according to data using 3D computed tomography. The kagome-structure scaffold and the conventional grid-structure scaffold (as a control group) were fabricated using a 3D printer with a precision extruding deposition head using poly(ε-caprolactone) (PCL). The two types of 3D printed scaffolds were implanted in the 8-shaped defect model on the rabbit calvarium. To evaluate the osteoconductivity of the implanted scaffolds, new bone formation, hematoxylin and eosin staining, immunohistochemistry, and Masson's trichrome staining were evaluated for 16 weeks after implantation of the scaffolds. To assess the mechanical robustness and stability of the kagome-structure scaffold, numerical analysis considering the 'elastic-perfectly plastic' material properties and deformation under self-contact condition was performed by finite element analysis. As a result, the kagome-structure scaffold fabricated using 3D printing technology showed excellent mechanical robustness and enhanced osteoconductivity than the control group. Therefore, the 3D printed kagome-structure scaffold can be a better option for bone regeneration in complex and large defects than the conventional grid-type 3D printed scaffold.


Assuntos
Regeneração Óssea , Teste de Materiais/métodos , Impressão Tridimensional , Crânio/patologia , Alicerces Teciduais/química , Animais , Fenômenos Biomecânicos , Modelos Animais de Doenças , Análise Numérica Assistida por Computador , Osteogênese , Poliésteres/química , Coelhos
6.
Tissue Eng Part C Methods ; 24(5): 255-262, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29466922

RESUMO

Bone graft materials are commonly used to regenerate various bone defects, but their application is often limited because of the complex defect shape in various clinical conditions. Hence, customized bone grafts using three-dimensional (3D) printing techniques have been developed. However, conventional simple bone defect models are limited for evaluating the benefits and manufacturing accuracy of 3D-printed customized bone grafts. Thus, the aim of the present study was to develop a complex-shaped bone defect model. We designed an 8-shaped bony defect that consists of two simple circles attached to the rabbit calvarium. To determine the critical-sized defect (CSD) of the 8-shaped defects, 5.6- and 7-mm-diameter trephine burs were tested, and the 7-mm-diameter bur could successfully create a CSD, which was easily reproducible on the rabbit calvarium. The rate of new bone formation was 28.65% ± 8.63% at 16 weeks following creation of the defect. To confirm its efficacy for clinical use, the 8-shaped defect was created on a rabbit calvarium and 3D computed tomography (CT) was performed. A stereolithography file was produced using the CT data, and a 3D-printed polycaprolactone graft was fabricated. Using our 8-shaped defect model, we were able to modify the tolerances of the bone graft and calvarial defect to fabricate a more precise bone graft. Customized characteristics of the bone graft were then used to improve the accuracy of the bone graft. In addition, we confirmed the fitting ability of the 3D-printed graft during implantation of the graft. Our 8-shaped defect model on the rabbit calvarium using a 7.0-mm trephine bur may be a useful CSD model for evaluating 3D-printed graft materials.


Assuntos
Transplante Ósseo , Impressão Tridimensional , Crânio/patologia , Animais , Regeneração Óssea , Modelos Animais de Doenças , Osteogênese , Coelhos , Crânio/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...