Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 15(23)2022 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-36499798

RESUMO

In this study, ground stability was evaluated through vertical displacement distribution and surface settlement results. In particular, a finite element analysis was conducted considering various factors (namely, cavity type and area, traffic load, pavement thickness, and elastic modulus) that affect a road above a cavity. The aim of this study was to evaluate the effect of pavement layer and traffic load condition on surface settlement according to the cavity shape. Field measurement results were analyzed and compared with the results of previous studies to verify the reliability of the numerical analysis method applied herein. After performing the numerical analysis using the verified method, ground stability was evaluated by analyzing the underground mechanical behavior of a road above a cavity. To this end, the correlations among the vertical displacement distribution, surface settlement, and influencing factors obtained from the analysis results were analyzed. In the numerical analysis, the ground was simulated with a hardening soil model based on the elastoplastic theory. This mechanical soil model can accurately reproduce the behavior of actual ground and can closely represent the mechanical behavior of the soil surrounding a cavity according to the cavity generation. In addition, the elapsed time was not considered when applying a load on the pavement layer, and a uniformly distributed load was applied. Consequently, it was found that, with increasing cavity area and traffic load and decreasing pavement thickness and elastic modulus, the vertical displacement and maximum surface settlement above the cavity increased, and the reduction in ground stability was greater. Furthermore, the reduction in ground stability was greater when the cavity was rectangular than when it was circular.

2.
Nanomaterials (Basel) ; 12(12)2022 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-35745298

RESUMO

The demand for synthetic diamonds and research on their use in next-generation semiconductor devices have recently increased. Microwave plasma chemical vapor deposition (MPCVD) is considered one of the most promising techniques for the mass production of large-sized and high-quality single-, micro- and nanocrystalline diamond films. Although the low-pressure resonant cavity MPCVD method can synthesize high-quality diamonds, improvements are needed in terms of the resulting area. In this study, a large-area diamond synthesis method was developed by arranging several point plasma sources capable of processing a small area and scanning a wafer. A unit combination of three plasma sources afforded a diamond film thickness uniformity of ±6.25% at a wafer width of 70 mm with a power of 700 W for each plasma source. Even distribution of the diamond grains in a size range of 0.1-1 µm on the thin-film surface was verified using field-emission scanning electron microscopy. Therefore, the proposed novel diamond synthesis method can be theoretically expanded to achieve large-area films.

3.
Sensors (Basel) ; 22(5)2022 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-35271051

RESUMO

Various types of motion blur are frequently observed in the images captured by sensors based on thermal and photon detectors. The difference in mechanisms between thermal and photon detectors directly results in different patterns of motion blur. Motivated by this observation, we propose a novel method to synthesize blurry images from sharp images by analyzing the mechanisms of the thermal detector. Further, we propose a novel blur kernel rendering method, which combines our proposed motion blur model with the inertial sensor in the thermal image domain. The accuracy of the blur kernel rendering method is evaluated by the task of thermal image deblurring. We construct a synthetic blurry image dataset based on acquired thermal images using an infrared camera for evaluation. This dataset is the first blurry thermal image dataset with ground-truth images in the thermal image domain. Qualitative and quantitative experiments are extensively carried out on our dataset, which show that our proposed method outperforms state-of-the-art methods.

4.
Rev Sci Instrum ; 92(1): 013507, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33514259

RESUMO

Optical emission spectroscopy is widely used in semiconductor and display manufacturing for plasma process monitoring. However, because of the contamination of the viewport, quantitative analysis is extremely difficult; therefore, qualitative analysis is used to detect species in the process. To extend plasma monitoring in advanced precise processes, the contamination problem of the viewport must be solved. We propose a new spectrum monitoring apparatus with a roll-to-roll transparent film window for optical diagnostics of a plasma system. By moving a transparent film in front of the viewport, contamination in the emission light path becomes negligible. However, the speed of the film should be optimized to reduce the maintenance period and to minimize measurement errors. We calculated the maximum thickness of SiO2, Si3N4, ITO, and the Ar/CHF3 plasma contaminant to suppress the electron temperature error measured by the line-intensity-ratio within 2% at 2 eV. The thickness of the Si3N4, ITO, and Ar/CHF3 plasma contaminant should be thinner than 12.5 nm, 7.5 nm, and 100 nm, respectively.

5.
Front Vet Sci ; 7: 598792, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33363237

RESUMO

A 9-year-old, intact male Shih Tzu dog presented with systemic weakness and peracute onset of tetraplegia. Tetraplegia with lower motor neuron signs was noted upon neurological examination. Diseases that cause acute flaccid tetraparesis, such as acute fulminating myasthenia gravis, polyradiculoneuritis, tick paralysis, and botulism, were ruled out based on the medical history, normal electrophysiological tests, and non-response to the neostigmine challenging test. Initial 0.3-Tesla (T) magnetic resonance imaging (MRI) findings included sharply demarcated intramedullary lesions at the C3-C6 level, mainly involving gray matter, which appeared hypo- to iso- intense on T1-weighted images (WIs), and hyperintense on T2-WIs and fluid-attenuated inversion recovery images. There was no enhancement on post-contrast T1-WIs. Neutrophilic pleocytosis was observed in the cerebrospinal fluid analysis. No clinical responses were observed for the treatment of non-infectious myelitis with an immunosuppressive dosage of prednisolone. A follow-up 3-T MRI 6 days later demonstrated hyperintensity on diffusion-WI (DWI) and a decreased apparent diffusion coefficient (ADC) value (0.54 × 10-3 mm2/s) of the spinal lesions. Through histological examination, a fibrocartilaginous embolism was definitively confirmed. This is the first report to describe an ischemic spinal injury visualized by DWI and ADC mapping with high-field MRI in a chondrodystrophic dog diagnosed with a fibrocartilaginous embolism.

6.
Rev Sci Instrum ; 87(12): 123501, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28040975

RESUMO

The novel technique of Plasma-Assisted Vapor Deposition (PAVD) is developed as a new deposition method for thin metal films. The PAVD technique yields a high-quality thin film without any heating of the substrate because evaporated particles acquire energy from plasma that is confined to the inside of the evaporation source. Experiments of silver thin film deposition have been carried out in conditions of pressure lower than 10-3 Pa. Pure silver plasma generation is verified by the measurement of the Ag-I peak using optical emission spectroscopy. A four point probe and a UV-VIS spectrophotometer are used to measure the electrical and optical properties of the silver film that is deposited by PAVD. For an ultra-thin silver film with a thickness of 6.5 nm, we obtain the result of high-performance silver film properties, including a sheet resistance <20 Ω sq-1 and a visible-range transmittance >75%. The PAVD-film properties show a low sheet resistance of 30% and the same transmittance with conventional thermal evaporation film. In the PAVD source, highly energetic particles and UV from plasma do not reach the substrate because the plasma is completely shielded by the optimized nozzle of the crucible. This new PAVD technique could be a realistic solution to improve the qualities of transparent electrodes for organic light emission device fabrication without causing damage to the organic layers.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...