Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Nanomicro Lett ; 15(1): 76, 2023 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-36976370

RESUMO

Although there is a high demand for absorption-dominant electromagnetic interference (EMI) shielding materials for 5G millimeter-wave (mmWave) frequencies, most current shielding materials are based on reflection-dominant conductive materials. While there are few absorption-dominant shielding materials proposed with magnetic materials, their working frequencies are usually limited to under 30 GHz. In this study, a novel multi-band absorption-dominant EMI shielding film with M-type strontium ferrites and a conductive grid is proposed. This film shows ultralow EMI reflection of less than 5% in multiple mmWave frequency bands with sub-millimeter thicknesses, while shielding more than 99.9% of EMI. The ultralow reflection frequency bands are controllable by tuning the ferromagnetic resonance frequency of M-type strontium ferrites and composite layer geometries. Two examples of shielding films with ultralow reflection frequencies, one for 39 and 52 GHz 5G telecommunication bands and the other for 60 and 77 GHz autonomous radar bands, are presented. The remarkably low reflectance and thinness of the proposed films provide an important advancement toward the commercialization of EMI shielding materials for 5G mmWave applications.

2.
Eur Spine J ; 31(5): 1260-1272, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35325298

RESUMO

PURPOSE: Our study aimed to evaluate non-inferiority of ProDisc-C to anterior cervical discectomy and fusion (ACDF) in terms of clinical outcomes and incidence of adjacent segment disease (ASD) at 24-months post-surgery in Asian patients with symptomatic cervical disc disease (SCDD). METHODS: This multicentre, prospective, randomized controlled trial was initiated after ethics committee approval at nine centres (China/Hong Kong/Korea/Singapore/Taiwan). Patients with single-level SCDD involving C3-C7-vertebral segments were randomized (2:1) into: group-A treated with ProDisc-C and group-B with ACDF. Assessments were conducted at baseline, 6-weeks, 3/6/12/18/24-months post-surgery and annually thereafter till 84-months. Primary endpoint was overall success at 24-months, defined as composite of: (1) ≥ 20% improvement in neck disability index (NDI); (2) maintained/improved neurologic parameters; (3) no implant removal/revision/re-operation at index level; and (4) no adverse/severe/life-threatening events. RESULTS: Of 120 patients (80ProDisc-C,40ACDF), 76 and 37 were treated as per protocol (PP). Overall success (PP) was 76.5% in group-A and 81.8% in group-B at 24-months (p = 0.12), indicating no clear non-inferiority of ProDisc-C to ACDF. Secondary outcomes improved for both groups with no significant inter-group differences. Occurrence of ASD was higher in group-B with no significant between-group differences. Range of motion (ROM) was sustained with ProDisc-C but lost with ACDF at 24-months. CONCLUSION: Cervical TDR with ProDisc-C is feasible, safe, and effective for treatment of SCDD in Asians. No clear non-inferiority was demonstrated between ProDisc-C and ACDF. However, patients treated with ProDisc-C demonstrated significant improvement in NDI, neurologic success, pain scores, and 36-item-short-form survey, along with ROM preservation at 24-months. Enrolment difficulties resulted in inability to achieve pre-planned sample size to prove non-inferiority. Future Asian-focused, large-scale studies are needed to establish unbiased efficacy of ProDisc-C to ACDF.


Assuntos
Degeneração do Disco Intervertebral , Fusão Vertebral , Substituição Total de Disco , Povo Asiático , Vértebras Cervicais/cirurgia , Discotomia/métodos , Seguimentos , Humanos , Degeneração do Disco Intervertebral/etiologia , Degeneração do Disco Intervertebral/cirurgia , Deslocamento do Disco Intervertebral , Estudos Prospectivos , Amplitude de Movimento Articular , Fusão Vertebral/métodos , Substituição Total de Disco/métodos , Resultado do Tratamento
3.
Nanomaterials (Basel) ; 13(1)2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36615937

RESUMO

Yttria-stabilized zirconia (YSZ) nanospheres were synthesized by calcination at 900 °C after the adsorption of Y3+ ions into the pores of a zirconium-based metal-organic framework (MOF). The synthesized 3YSZ (zirconia doped with 3 mol% Y2O3), 8YSZ (8 mol% Y2O3), and 30YSZ (30 mol% Y2O3) nanospheres were found to exhibit uniform sizes and shapes. Complex permittivity and complex permeability were carried out in K-band (i.e., 18-26.5 GHz) to determine their suitability for use as low-k materials in 5G communications. The real and imaginary parts of the permittivity of the sintered 3YSZ were determined to be 21.24 and 0.12, respectively, while those of 8YSZ were 22.80 and 0.16, and those of 30YSZ were 7.16 and 0.38. Control of the real part of the permittivity in the sintered YSZ was facilitated by modifying the Y2O3 content, thereby rendering this material an electronic ceramic with potential for use in high-frequency 5G communications due to its excellent mechanical properties, high chemical resistance, and good thermal stability. In particular, it could be employed as an exterior material for electronic communication products requiring the minimization of information loss.

4.
ACS Appl Mater Interfaces ; 12(45): 50803-50811, 2020 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-33135419

RESUMO

Fiber strain sensors that are directly woven into smart textiles play an important role in wearable systems. These sensors require a high sensitivity to detect the subtle strain in practical applications. However, traditional fiber strain sensors with constant diameters undergo homogeneous strain distribution in the axial direction, thereby limiting the sensitivity improvement. Herein, a novel strategy of internal or external structural design is proposed to significantly improve the sensitivity of fiber strain sensors. The fibers are produced with directional increases in diameter (internal design) or polydimethylsiloxane (PDMS) microbeads attached to surfaces (external design) by combining hollow glass tubes used as templates with PDMS drops. The structural modification of the fiber significantly impacts the sensing performance. After optimizing structural parameters, the highest gauge factor reaches 123.1 in the internal-external structure design at 25% strain. A comprehensive analysis reveals that the desirable scheme is the internal structural design, which features a high sensitivity of 110 with a 100% improvement at ∼5-20% strain. Because of the sufficiently robust interface, even at the 800th cycle, fiber sensors still possessed an excellent stable performance. The morphology evolution mechanism indicates that the resistance increase is closely related with the increased peak width and distance, and the appearance of gaps. Based on the finite element modeling simulation, the quantified effective contributions of different strategies positively correlate with the improved sensitivity. The proposed fiber strain sensors, which are woven into the two-dimensional network structure, exhibit an excellent capability for displacement monitoring and facilitate the traffic control of crossroads.

5.
Materials (Basel) ; 13(7)2020 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-32235613

RESUMO

This study was conducted on titanium diboride (TiB2) reinforced Al metal matrix composites (MMCs) with improved properties using a TiB2 and aluminum (Al) 1050 alloy. Al composites reinforced with fine TiB2 at volume ratios of more than 60% were successfully fabricated via the liquid pressing infiltration (LPI) process, which can be used to apply gas pressure at a high temperature. The microstructure of the TiB2-Al composite fabricated at 1000 °C with pressurization of 10 bar for 1 h showed that molten Al effectively infiltrated into the high volume-fraction TiB2 preform due to the improved wettability and external gas pressurization. In addition, the interface of TiB2 and Al not only had no cracks or pores but also had no brittle intermetallic compounds. In conclusion, TiB2-Al composite, which has a sound microstructure without defects, has improved mechanical properties, such as hardness and strength, due to effective load transfer from the Al matrix to the fine TiB2 reinforcement.

6.
Materials (Basel) ; 12(20)2019 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-31623088

RESUMO

Aluminum alloy (Al7075) composites reinforced with a high volume fraction of silicon carbide (SiC) were produced by a liquid-pressing process. The characterization of their microstructure showed that SiC particles corresponding to a volume fraction greater than 60% were uniformly distributed in the composite, and Mg2Si precipitates were present at the interface between the matrix and the reinforcement. A superior compressive strength (1130 MPa) was obtained by an effective load transfer to the hard ceramic particles. After solution heat treatment and artificial aging, the Mg2Si precipitates decomposed from rod-shaped large particles to smaller spherical particles, which led to an increase of the compressive strength by more than 200 MPa. The strengthening mechanism is discussed on the basis of the observed microstructural evolution.

7.
J Korean Neurosurg Soc ; 61(6): 737-746, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30396247

RESUMO

OBJECTIVE: The purpose of this study was to compare the cosmetic outcome and complications after cranioplasty (CP) due to three different implant materials, and analyze the mean implant survival and cumulative survival rate based on these results. METHODS: We reviewed 108 patients retrospectively who underwent CP between January 2014 and November 2016. Autologous bone (AB; 45 patients) and synthetic materials with porous polyethylene (PP; 32 patients) and custom-made 3-dimensional printed titanium mesh (CT; 31 patients) were used as implants. RESULTS: Regardless of implanted materials, more than 89.8% of the CP patients were satisfied with the cosmetic outcome. No statistically significant difference was observed among the three groups. The overall postoperative complication rates of each group were 31.1% in the AB group, 15.6% in the PP group and 3.2% in the CT group. The CT group showed lower complication rates compared with AB and PP groups (χ2-test : AB vs. PP, p=0.34; AB vs. CT, p=0.00; PP vs. CT, p=0.03). The AB and PP groups demonstrated a higher post-CP infection rate (11.1% and 6.3%) than the CT group (3.2%). However, no significant difference in the incidence of post-CP infection was observed among the three groups. The PP and CT groups demonstrated a higher mean implant survival time and cumulative survival rate than the AB group at the last follow-up (p<0.05). CONCLUSION: In comparison with AB and PP, cranioplasty with CT shows benefits in terms of lower post-CP complication, less intraoperative bleeding loss, shorter operation time and in-hospital stay. The PP and CT groups showed higher implant survival time and cumulative survival rate compared with the AB group.

8.
ACS Appl Mater Interfaces ; 10(38): 32323-32330, 2018 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-30168328

RESUMO

We report the effect of epoxy adhesion layers with different mechanical or physical property on a magnetoelectric (ME) composite laminate composed of FeBSi alloy (Metglas)/single-crystal Pb(Mg1/3Nb2/3)O3-Pb(Zr,Ti)O3/Metglas to achieve an improved ME conversion performance. Through theoretical simulation, it was revealed that the Young's modulus and the thickness of interfacial adhesives were major parameters that influence the conversion efficiency in ME composites. In the experimental evaluation, we utilized three epoxy materials with a distinct Young's modulus and adjusted the average thickness of the adhesion layers to optimize the ME conversion. The experimental results show that a thin epoxy layer with a high Young's modulus provided the best performance in the inorganic-based ME conversion process. By tailoring the interfacial adhesion property, the ME laminate generated a high conversion coefficient of 328.8 V/(cm Oe), with a mechanical quality factor of 132.0 at the resonance mode. Moreover, we demonstrated a highly sensitive alternating current magnetic field sensor that had a detection resolution below 10 pT. The optimization of the epoxy layers in the ME laminate composite provided significant enhancement of the ME response in a simple manner.

9.
Int J Occup Saf Ergon ; 24(2): 165-170, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27976980

RESUMO

This study investigates differences between male and female public office workers' satisfaction levels, sick building syndrome (SBS) symptoms and musculoskeletal disorder (MSD) complaints in workplace and office environments. Questionnaire surveys were performed in 30 offices from 15 public institutions. Male and female workers of the same age were coupled and selected from each office, gathering a total of 120 male and 120 female subjects. The results show that differences exist between genders in noise and lighting satisfaction levels, SBS-related symptoms (eye, nose, skin) and MSD complaints of hand/wrist/finger, while there is no difference in overall satisfaction level of office environments. The study also suggests that office design for public office workers should take into account gender differences in preventing MSDs and also SBS. The findings of this study are expected to serve as basic data for designing effective public office environments.


Assuntos
Doenças Musculoesqueléticas/epidemiologia , Fatores Sexuais , Síndrome do Edifício Doente/epidemiologia , Local de Trabalho , Adulto , Poluição do Ar em Ambientes Fechados/efeitos adversos , Feminino , Humanos , Satisfação no Emprego , Iluminação , Masculino , Pessoa de Meia-Idade , Ruído Ocupacional/efeitos adversos , Doenças Profissionais/epidemiologia , Setor Público , República da Coreia/epidemiologia , Fatores de Risco , Inquéritos e Questionários
10.
Sci Rep ; 7(1): 14943, 2017 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-29097802

RESUMO

In order to explore the possibility of using carbon nanotube (CNT) to introduce and control the temperature coefficient of resistance (TCR) of metal matrix composite, relatively thick and short multi-walled CNTs (MWCNTs) were introduced in the metal matrix with in-situ formation of chromium carbide (Cr7C3) at the CNT/copper (Cu) interface. We demonstrate that incompatible properties such as electrical conductivity and TCR can be achieved simultaneously by introducing MWCNTs in the Cu matrix, with control of the interfacial resistivity using the MWCNT/Cr7C3-Cu system. High electrical conductivity of 94.66 IACS and low TCR of 1,451 10-6 °C-1 are achieved in the 5 vol.% MWCNT-CuCr composite. In-situ formation of Cr7C3 nanostructures at the MWCNT/Cu interface by reaction of diffused Cr atoms and amorphous carbon of MWCNTs would assist in improving the electrical properties of the MWCNT-CuCr composites.

11.
J Korean Neurosurg Soc ; 60(6): 676-683, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29142627

RESUMO

OBJECTIVE: The purpose of this study is to evaluate the efficacy and safety of 3-level hybrid surgery (HS), which combines fusion and cervical disc replacement (CDR), compared to 3-level fusionin patient with cervical spondylosis involving 3 levels. METHODS: Patients in the anterior cervical discectomy and fusion (ACDF) group (n=30) underwent 3-level fusion and the HS group (n=19) underwent combined surgery with fusion and CDR. Clinical outcomes were evaluated using the visual analogue scale for the arm, the neck disability index (NDI), Odom criteria and postoperative complications. The cervical range of motion (ROM), fusion rate and adjacent segments degeneration were assessed with radiographs. RESULTS: Significant improvements in arm pain relief and functional outcome were observed in ACDF and HS group. The NDI in the HS group showed better improvement 6 months after surgery than that of the ACDF group. The ACDF group had a lower fusion rate, higher incidence of device related complications and radiological changes in adjacent segments compared with the HS group. The better recovery of cervical ROM was observed in HS group. However, that of the ACDF group was significantly decreased and did not recover. CONCLUSION: The HS group was better than the ACDF group in terms of NDI, cervical ROM, fusion rate, incidence of postoperative complications and adjacent segment degeneration.

12.
Mol Cells ; 40(10): 714-730, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29047256

RESUMO

Pre-mRNA splicing further increases protein diversity acquired through evolution. The underlying driving forces for this phenomenon are unknown, especially in terms of gene expression. A rice alternatively spliced transcript detection microarray (ASDM) and RNA sequencing (RNA-Seq) were applied to differentiate the transcriptome of 4 representative organs of Oryza sativa L. cv. Ilmi: leaves, roots, 1-cm-stage panicles and young seeds at 21 days after pollination. Comparison of data obtained by microarray and RNA-Seq showed a bell-shaped distribution and a co-lineation for highly expressed genes. Transcripts were classified according to the degree of organ enrichment using a coefficient value (CV, the ratio of the standard deviation to the mean values): highly variable (CVI), variable (CVII), and constitutive (CVIII) groups. A higher index of the portion of loci with alternatively spliced transcripts in a group (IAST) value was observed for the constitutive group. Genes of the highly variable group showed the characteristics of the examined organs, and alternatively spliced transcripts tended to exhibit the same organ specificity or less organ preferences, with avoidance of 'organ distinctness'. In addition, within a locus, a tendency of higher expression was found for transcripts with a longer coding sequence (CDS), and a spliced intron was the most commonly found type of alternative splicing for an extended CDS. Thus, pre-mRNA splicing might have evolved to retain maximum functionality in terms of organ preference and multiplicity.


Assuntos
Processamento Alternativo/genética , Oryza/genética , Splicing de RNA/genética , Transcriptoma/genética , Éxons/genética , Regulação da Expressão Gênica de Plantas , Genoma de Planta , Íntrons/genética , Análise em Microsséries , Folhas de Planta/genética , Folhas de Planta/crescimento & desenvolvimento , Raízes de Plantas/genética , Raízes de Plantas/metabolismo , Sementes/genética , Sementes/crescimento & desenvolvimento
13.
Clin Neurol Neurosurg ; 162: 59-66, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28938108

RESUMO

OBJECTIVE: The purpose of this study is to compare the efficacy and safety of anterior cervical discectomy and fusion (ACDF) and cervical total disc replacement (CTDR) as revision surgeries for symptomatic adjacent segment degeneration (ASD) in cases with previous ACDF. PATIENTS AND METHODS: Between 2010 and 2014, 41 patients with previous cervical fusion surgery underwent ACDF or CTDR for symptomatic ASD. Twenty-two patients in the ACDF group underwent 26 ACDFs, and 19 patients in the CTDR group underwent 25 arthroplasties for symptomatic ASD. Clinical outcomes were assessed by a visual analogue scale (VAS) for arm pain, the neck disability index (NDI) and Odom's criteria. Radiological evaluations were performed preoperatively and postoperatively to measure changes in the range of motion (ROM) of the cervical spine and adjacent segments and arthroplasty level. The radiological change of ASD was assessed in radiographs. RESULTS: Clinical outcomes as assessed with VAS for arm pain and Odom's criteria were significantly improved in both groups. The CTDR group showed better NDI improvement after surgery (P<0.05). The mean C2-7 ROM of the CTDR group revealed faster recovery than did that of the ACDF group and the preoperative values were recovered at the last follow-up visit. There was a significant difference in the ROM of the inferior adjacent segment between the ACDF and CTDR groups (P<0.05). The ACDF group had a higher incidence of radiological changes in the adjacent segment compared with the CTDR group (P<0.05). CONCLUSIONS: The 2-year clinical results of CTDR for symptomatic ASD are safe and are comparable to the outcomes of ACDF in terms of arm pain relief and functional recovery. The CTDR group showed better NDI improvement, faster C2-7 ROM recovery, less of an increase in ROM in the inferior adjacent segment, and a lower incidence of adjacent segment degeneration than did the ACDF group.


Assuntos
Vértebras Cervicais/cirurgia , Discotomia/métodos , Degeneração do Disco Intervertebral/cirurgia , Avaliação de Resultados em Cuidados de Saúde/métodos , Reoperação/métodos , Fusão Vertebral/métodos , Substituição Total de Disco/métodos , Adulto , Idoso , Vértebras Cervicais/patologia , Feminino , Seguimentos , Humanos , Degeneração do Disco Intervertebral/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
14.
Brain Tumor Res Treat ; 5(1): 34-36, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28516077

RESUMO

Toxoplasmic encephalitis (TE) is an opportunistic infection found in immunocompromised patients and TE related cerebral mass lesion is often reported in acquired immunodeficiency acquired immunodeficiency syndrome (AIDS) patients. However, incidence of TE related AIDS in Korea is still rare and is unfamiliar to neurosurgeons. Differential diagnosis is needed to rule out other brain lesions. A 39-year-old man visited the emergency room with rapid progressive left hemiparesis. Magnetic resonance imaging showed a ring-enhanced mass lesion in his right frontal lobe. Human immunodeficiency virus and Toxoplasma gondii immunoglobulin G were tested positive by a serologic test. We report here a rare case of patient with TE related AIDS.

15.
Saf Health Work ; 7(2): 138-42, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27340601

RESUMO

BACKGROUND: Household waste collectors (HWCs) are exposed to hazardous conditions. This study investigates the patterns of workplace injuries and work-related illnesses of HWCs. METHODS: This study uses cases of workplace injuries and work-related illnesses of HWCs that occurred between 2010 and 2011. We analyzed 325 cases of injuries and 36 cases of illnesses according to the workers' age, length of employment, size of workplace, injured part of body, day and month of injury, type of accident, agency of accident, and collection process. RESULTS: There were significant differences in the effect of workers' length of employment, injured part of body, type of accident, agency of accident, and collection process. Results show that most injuries occur in workers in their 50s and older. This study also shows that 51.4% of injuries occur at businesses with 49 employees or fewer. Injuries to waste collectors happen most often when workers are electrocuted after slipping on the ground. The second most prevalent form of injury is falling, which usually happens when workers hang from the rear of the truck during transportation or otherwise slip and fall from the truck. Work-related illnesses amongst waste collectors are mostly musculoskeletal conditions due to damaging postures. CONCLUSION: These findings will be instructive in devising policies and guidelines for preventing workplace injuries and work-related illnesses of HWCs.

16.
Saf Health Work ; 7(1): 38-42, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27014489

RESUMO

BACKGROUND: Truck driving is known as one of the occupations with the highest accident rate. This study investigates the characteristics of traffic collisions according to road types (expressway and rural road). METHODS: Classifying 267 accidents into expressway and rural road, we analyzed them based on driver characteristics (age, working experience, size of employment), time characteristics (day of accident, time, weather), and accident characteristics (accident causes, accident locations, accident types, driving conditions). RESULTS: When we compared the accidents by road conditions, no differences were found between the driver characteristics. However, from the accident characteristics, the injured person distributions were different by the road conditions. In particular, driving while drowsy is shown to be highly related with the accident characteristics. CONCLUSION: This study can be used as a guideline and a base line to develop a plan of action to prevent traffic accidents. It can also help to prepare formal regulations about a truck driver's vehicle maintenance and driving attitude for a precaution on road accidents.

17.
ACS Nano ; 9(6): 5884-92, 2015 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-25970127

RESUMO

Lithium metal is considered to be the most promising anode for next-generation batteries due to its high energy density of 3840 mAh g(-1). However, the extreme reactivity of the Li surface can induce parasitic reactions with solvents, contamination, and shuttled active species in the electrolyte, reducing the performance of batteries employing Li metal anodes. One promising solution to this issue is application of thin chemical protection layers to the Li metal surface. Using a custom-made ultrahigh vacuum integrated deposition and characterization system, we demonstrate atomic layer deposition (ALD) of protection layers directly on Li metal with exquisite thickness control. We demonstrate as a proof-of-concept that a 14 nm thick ALD Al2O3 layer can protect the Li surface from corrosion due to atmosphere, sulfur, and electrolyte exposure. Using Li-S battery cells as a test system, we demonstrate an improved capacity retention using ALD-protected anodes over cells assembled with bare Li metal anodes for up to 100 cycles.

18.
Korean J Neurotrauma ; 11(2): 191-4, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27169093

RESUMO

Esophageal perforation is a serious possible complication after anterior cervical discectomy and fusion (ACDF). It usually occurs during the first postoperative day. Esophageal perforation is a potentially life-threatening complication. A 63-year-old man who underwent ACDF 8 years prior visited our emergency room with recurrent aspiration pneumonia, fever, dysphagia and neck pain. Endoscopic study showed esophageal perforation by cervical plate. Successful treatment of the perforation resulted after surgical repair using a sternocleidomastoid muscle flap. We presented a rare case of delayed esophageal perforation after ACDF and successful treatment of the perforation by surgical repair using a sternocleidomastoid muscle flap.

19.
J Cerebrovasc Endovasc Neurosurg ; 16(3): 200-8, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25340021

RESUMO

OBJECTIVE: According to the development of endovascular technique and devices, larger aneurysms on the distal internal carotid artery (ICA) can be treated using a less invasive method. The authors report on clinical and angiographic outcomes of these aneurysms treated using an endovascular technique. MATERIALS AND METHODS: Data on 21 patients with large aneurysms at distal ICA treated by endovascular method between January 2005 and December 2012 were included in this retrospective analysis. RESULTS: Clinical outcome of patients showed strong correlation with the initial neurologic status (p < 0.05). Aneurysm morphology showed saccular, fusiform, and wide-neck in 12, six and three patients. Six patients underwent stent assisted coiling and the other 15 patients underwent simple coiling. Aneurysm occlusion was performed immediately after embolization with near-complete (Raymond class 1-2) in 20 patients (95.2%) and incomplete (Raymond class 3) in one patient (4.8%). Delayed thrombotic occlusion occurred in two patients and their clinical result was fatal. Another five patients died in the hospital, from massive brain edema and/or increased intracranial pressure due to initial subarachnoid hemorrhage. Overall mortality was 30% (seven out of 21). Fatal complication related to the endovascular procedure occurred in two patients with thrombosis at middle cerebral artery (one with stent, the other without it). CONCLUSION: Recent developed endovascular device and technique is safe enough and a less invasive method for distal large or giant aneurysms. Based on our analysis of the study, we suspect that coil embolization of large distal ICA aneurysms (with or without stenting) is effective and safe.

20.
Korean J Neurotrauma ; 10(2): 134-6, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27169049

RESUMO

Acute subdural hematoma (ASDH) constitutes one of the most critical emergencies in neurosurgery and rapid spontaneous resolution of ASDH is an infrequent phenomenon. Several mechanisms have been attributed to explain this phenomenon including redistribution of subdural blood, dilution by cerebral spinal fluid and brain atrophy. Rapid resolution of ASDH related to coagulopathy is a rare phenomenon; to our knowledge, only one case has been reported. We report on a patient who showed rapid resolution of ASDH with coagulopathy and also discuss such a rare case with speculation of the coagulopathy as a factor to promote this phenomenon.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA