Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Vasc Endovasc Surg ; 59(1): 7-15, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31761570

RESUMO

OBJECTIVE: Branched stent grafts represent a viable option for left subclavian artery (LSA) revascularisation in patients treated by thoracic endovascular aortic repair (TEVAR) for Zone 2 lesions. This study investigated the haemodynamic performance of different LSA branched stent graft configurations as potential determinants of thrombotic and stroke risks. METHODS: A three dimensional aortic arch geometry extracted from post-operative computed tomography images of a TEVAR patient using a single LSA branched aortic endograft was modified in silico to obtain ten potential LSA branched stent graft configurations: five down facing (0-5 - 10 mm aortic protrusion with 10-12 mm internal diameter), four curved (30-60° with antegrade/retrograde orientation), and one LSA orifice misalignment. The 0 mm down facing stent graft was considered base configuration. Computational fluid dynamic analyses were performed to identify differences in pressure, energy, and wall shear stress (WSS) based parameters. RESULTS: Total pressure drop and energy loss variations among configurations were not greater than 5 mmHg (6% of mean arterial pressure) and 5.7 mW (0.7% of cardiac power), respectively. Protrusions up to 5 mm created clinically insignificant flow disturbances. However, stent graft protrusions further into the aortic lumen created more complex haemodynamics, characterised by larger energy loss and more prominent flow recirculation. Protrusion greater than 5 mm into the lumen was associated with larger areas of elevated maximum WSS (>20 Pa) along the outer surface of the branched stent graft. CONCLUSION: Arterial haemodynamic characteristics are affected by LSA branched stent graft configurations, with pressure drops and energy losses likely to be clinically insignificant. The length of the stent graft protrusion into the aortic lumen generated the largest haemodynamic variations in the aortic system. Protrusions up to 5 mm have smaller risk of potential thrombus generation. Conversely, larger protrusions into the aortic lumen showed more disturbed haemodynamics, suggesting a greater risk of potential thrombus formation, which may be clinically important over time.


Assuntos
Aorta Torácica/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Hemodinâmica/fisiologia , Stents/efeitos adversos , Artéria Subclávia/fisiopatologia , Idoso , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Simulação por Computador , Desenho Assistido por Computador , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Modelos Anatômicos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/prevenção & controle , Desenho de Prótese/efeitos adversos , Desenho de Prótese/métodos , Artéria Subclávia/cirurgia , Trombose/etiologia , Trombose/fisiopatologia , Trombose/prevenção & controle , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...