Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Catheter Cardiovasc Interv ; 101(3): 505-510, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36651339

RESUMO

OBJECTIVE: The elevated risk of adverse events following percutaneous coronary intervention in diabetic patients persists with newer-generation DES. The polymer-free amphilimus-eluting stent (PF-AES) possesses characteristics with a potentially enhanced performance in patients with diabetes. Data from the 1-year follow-up period has been previously published. The aim of this subanalysis was to assess long-term performance of two contemporary drug-eluting stents (DES) in a diabetic population. METHODS: In the ReCre8 trial, patients were stratified for diabetes and troponin status, and randomized to implantation of a permanent polymer zotarolimus-eluting stent (PP-ZES) or PF-AES. The primary endpoint was target-lesion failure (TLF), a composite of cardiac death, target-vessel myocardial infarction and target-lesion revascularization. Clinical outcomes between discharge and 3 years follow-up were assessed. RESULTS: A total of 302 patients with diabetes were included in this analysis. After 3 years, TLF occurred in 12.5% of PP-ZES patients versus 10.0% in PF-AES patients (p = 0.46). Similarly, the separate components of TLF were comparable between the two study arms. The secondary composite endpoint of NACE was higher in the PP-ZES arm with 45 cases (29.6%) versus 30 cases (20.0%) in the PF-AES arm (p = 0.036). In the insulin-dependent diabetic population, TLF occurred in 19.1% of PP-ZES patients versus 10.4% of PF-AES patients (p = 0.21). NACE occurred in 40.4% of PP-ZES patients versus 27.1% of PF-AES patients (p = 0.10). CONCLUSIONS: This subanalysis shows that the use of PF-AES results in similar clinical outcomes as compared to PP-ZES, yet some benefits of use of PF-AES in diabetic patients may prevail. Future dedicated trials should confirm these findings.


Assuntos
Fármacos Cardiovasculares , Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/induzido quimicamente , Seguimentos , Fatores de Risco , Resultado do Tratamento , Diabetes Mellitus/diagnóstico , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Fármacos Cardiovasculares/efeitos adversos
2.
Catheter Cardiovasc Interv ; 99(2): 366-372, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33811730

RESUMO

OBJECTIVES: The purpose of this analysis was to compare target-lesion failure (TLF) of a permanent polymer zotarolimus-eluting stent (PP-ZES) versus a polymer-free amphilimus-eluting stent (PF-AES) in diabetics. BACKGROUND: The improvement of outcomes with new-generation drug-eluting stent as seen in the general population is less pronounced among diabetics. The PF-AES introduces an elution-technology with potential enhanced performance in diabetics. METHODS: In this subanalysis of the ReCre8 trial, patients were randomized to either a PP-ZES or PF-AES after stratification for diabetes and troponin status. The primary device-oriented endpoint was TLF, a composite of cardiac death, target-vessel myocardial infarction and target-lesion revascularization. RESULTS: In the ReCre8 trial, 304 (20%) patients were diabetic and 96 (6%) had insulin-dependent diabetes mellitus. There was no statistically significant difference between the two study arms regarding the primary endpoint (PP-ZES 7.2% vs. PF-AES 4.0%; p = .21), although the composite of net adverse clinical events was higher in the PP-ZES arm (15.7 vs. 8.0%; p = .035). Stent thrombosis was low in both groups with no cases in the PP-ZES arm and 1 case in the PF-AES arm (p = .32). Regarding insulin-treated diabetics, TLF was higher in the PP-ZES arm (14.9 vs. 2.1%; p = .022). CONCLUSIONS: Diabetics could potentially benefit from a dedicated stent, releasing sirolimus with a lipophilic carrier (amphilimus-formulation). Future trials should confirm the potential benefit of a PF-AES in this population.


Assuntos
Fármacos Cardiovasculares , Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/induzido quimicamente , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Desenho de Prótese , Stents , Resultado do Tratamento
3.
Am Heart J Plus ; 24: 100227, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38560639

RESUMO

Objectives: In an all-comers cohort undergoing percutaneous coronary intervention (PCI), we aimed to assess prevalence of high bleeding risk (HBR) patients and impact of HBR and dual antiplatelet therapy (DAPT) on clinical events. Background: HBR represents a complex subgroup of patients undergoing PCI. Methods: In the ReCre8 trial, patients undergoing PCI were stratified for troponin status and diabetes and randomized to a permanent polymer zotarolimus-eluting- or polymer-free amphilimus-eluting stent. Patients were treated with 12 months (troponin-positive) or one month (troponin-negative) of DAPT. We evaluated clinical outcomes in patients with and without HBR according to the Academic Research Consortium for High Bleeding Risk criteria. Results: From a total of 1488 patients included in this subanalysis, 406 patients (27.3 %) were identified as being at HBR. Among HBR patients, target-lesion failure (TLF) was similar after one year yet was higher after three years (13.3 % vs. 9.1 %; p = 0.013), compared to non-HBR patients. There was no difference in Bleeding Academic Research Consortium (BARC) 3 to 5 bleeding, however BARC 2 to 5 bleeding was higher after three years with 4.9 % vs. 3.0 % (p = 0.037). There were no differences between troponin-positive (12-months DAPT) and -negative (1-month DAPT) HBR patients with respect to ischemic and bleeding outcomes. Conclusions: In this all-comers population of PCI patients, a higher TLF rate among HBR patients at long-term follow-up was found, underlining the complexities involving treatment of HBR patients. We did not observe statistically significant differences in BARC 3 to 5 bleeding between HBR and non-HBR patients regardless of DAPT duration. Clinical trial registration: URL: http://www.clinicaltrials.gov, unique identifier: NCT02328898.

4.
JACC Cardiovasc Interv ; 14(22): 2477-2486, 2021 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-34794654

RESUMO

OBJECTIVES: The aim of this analysis was to assess long-term clinical outcomes of the polymer-free Amphilimus-eluting stent (PF-AES) compared with a latest generation permanent-polymer drug-eluting stent (DES) in an all-comers population. BACKGROUND: PF-AES possess multiple properties improving targeted drug elution without the presence of polymers. Evaluation of long-term clinical performance of PF-AES versus latest generation permanent-polymer DES has not yet been performed in a large randomized trial introducing shortened dual-antiplatelet therapy. METHODS: In this physician-initiated, multicenter, randomized, all-comers trial, patients undergoing percutaneous coronary intervention with implantation of DES were enrolled. Patients were stratified for diabetes and troponin status and randomized to implantation of a permanent-polymer zotarolimus-eluting stent (PP-ZES) or a PF-AES. Dual-antiplatelet therapy duration was 12 months in troponin-positive patients and 1 month in troponin-negative patients. A noninferiority analysis was conducted to compare the 2 arms regarding target lesion failure (TLF) between 1 and 3 years. RESULTS: A total of 1,491 patients were randomized and treated. In this landmark analysis, between 1- and 3-year follow-up, TLF occurred in 35 patients (4.9%) in the PP-ZES arm and 37 PF-AES patients (5.1%). Clinical noninferiority of the PF-AES was confirmed, with a risk difference of 0.2% (upper limit 1-sided 95% CI: 2.2%; Pnoninferiority = 0.0031). CONCLUSIONS: ReCre8 (Randomized "All-Comer" Evaluation of a Permanent Polymer Resolute Integrity Stent Versus a Polymer Free Cre8 Stent) is the first randomized, multicenter trial with a head-to-head comparison of PP-ZES compared with PF-AES to investigate clinical outcomes of these new-generation DES in an all-comers population with long-term follow-up. On the basis of the present results, PF-AES are clinically noninferior to PP-ZES regarding TLF between 1 and 3 years. (Randomized "All-Comer" Evaluation of a Permanent Polymer Resolute Integrity Stent Versus a Polymer Free Cre8 Stent; NCT02328898).


Assuntos
Fármacos Cardiovasculares , Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
BMJ Open ; 9(3): e025793, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30826767

RESUMO

INTRODUCTION: Anatomic stenosis evaluation on coronary CT angiography (CCTA) lacks specificity in indicating the functional significance of a stenosis. Recent developments in CT techniques (including dual-layer spectral detector CT [SDCT] and static stress CT perfusion [CTP]) and image analyses (including fractional flow reserve [FFR] derived from CCTA images [FFRCT] and deep learning analysis [DL]) are potential strategies to increase the specificity of CCTA by combining both anatomical and functional information in one investigation. The aim of the current study is to assess the diagnostic performance of (combinations of) SDCT, CTP, FFRCT and DL for the identification of functionally significant coronary artery stenosis. METHODS AND ANALYSIS: Seventy-five patients aged 18 years and older with stable angina and known coronary artery disease and scheduled to undergo clinically indicated invasive FFR will be enrolled. All subjects will undergo the following SDCT scans: coronary calcium scoring, static stress CTP, rest CCTA and if indicated (history of myocardial infarction) a delayed enhancement acquisition. Invasive FFR of ≤0.80, measured within 30 days after the SDCT scans, will be used as reference to indicate a functionally significant stenosis. The primary study endpoint is the diagnostic performance of SDCT (including CTP) for the identification of functionally significant coronary artery stenosis. Secondary study endpoint is the diagnostic performance of SDCT, CTP, FFRCT and DL separately and combined for the identification of functionally significant coronary artery stenosis. ETHICS AND DISSEMINATION: Ethical approval was obtained. All subjects will provide written informed consent. Study findings will be disseminated through peer-reviewed conference presentations and journal publications. TRIAL REGISTRATION NUMBER: NCT03139006; Pre-results.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Ensaios Clínicos Controlados como Assunto/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Adolescente , Adulto , Idoso , Técnicas de Imagem Cardíaca/métodos , Reserva Fracionada de Fluxo Miocárdico , Humanos , Aprendizado de Máquina , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Estudos Prospectivos , Tamanho da Amostra , Adulto Jovem
7.
Eur J Heart Fail ; 13(2): 186-94, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21106543

RESUMO

AIMS: The aim of this study was to investigate (i) the baseline patterns of segmental peak myocardial strain (PMS) in heart failure (HF) patients with ventricular conduction delay, (ii) changes in patterns of segmental PMS induced by cardiac resynchronization therapy (CRT), and (iii) whether they differ between CRT responders and non-responders. METHODS AND RESULTS: Segmental and global longitudinal (L-) and radial (R-) PMS measurements derived from speckle tracking were prospectively obtained in 85 HF patients with intraventricular conduction delay before and 6 months after CRT device implantation and in 30 healthy subjects. Segmental strain analysis in HF patients showed pronounced heterogeneity both in longitudinal and in radial directions with the lowest amplitudes in the septum and the highest amplitudes in the lateral and posterior walls. After CRT, 60% of the patients were responders (≥ 15% reduction in end-systolic volume). Before CRT, responders showed higher global R-PMS than non-responders (19.5 ± 13.4 vs.13.1 ± 4.8%, respectively; P = 0.04) despite similar global L-PMS. After CRT, responders showed an increase in L-PMS in most segments and a homogeneous increase in R-PMS, leading to a more uniform pattern of strain and an improved global L-PMS and R-PMS. In contrast, in non-responders, the gain in L-PMS and R-PMS in septal segments was completely offset by a decrease in posterolateral segments, failing to decrease segmental heterogeneity and to increase global L-PMS and R-PMS. CONCLUSION: Heart failure patients with ventricular conduction delay show pronounced heterogeneous patterns of segmental PMS, which can be reversed by CRT.


Assuntos
Estimulação Cardíaca Artificial/métodos , Ecocardiografia Doppler/métodos , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/terapia , Estresse Fisiológico/fisiologia , Disfunção Ventricular Esquerda/terapia , Idoso , Terapia de Ressincronização Cardíaca/métodos , Estudos de Casos e Controles , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Contração Miocárdica/fisiologia , Prognóstico , Medição de Risco , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Análise de Sobrevida , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia , Remodelação Ventricular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...