Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Vnitr Lek ; 68(E-5): 20-26, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36283813

RESUMO

INTRODUCTION: Single stage thoracoscopic radiofrequency ablation (RFA) is a treatment method for persistent and long-term persistent atrial fibrillation (AF) offering the possibility for patients otherwise inconsolable by conventional catheter RFA. We present a pilot group of patients after the introduction of the new method at our clinical center. Patients group: A total of 52 patients aged 61.82 ± 9.7 years underwent single stage hybrid ablation (thoracoscopic isolation of pulmonary veins and box lesion followed by catheter verification of the surgical procedure effectivness) for symptomatic persistent and long-term persistent AF with significantly dilated left atrium 57.9 ± 11.0mm in the period September 2016-March 2019. RESULTS: The median duration of the procedure was 232 minutes and the median duration of hospitalization was 10 days. At discharge, 52 patients (100%) had sinus rhythm. 48 of 52 patients (92.3%) had a 6-month follow-up. 41 of 48 (85.4%) and 38 of 44 (86.4%) of patients were AF free at 3-month and 6-month follow-up, respectively. Acute complications were: one left atrial perforation resolved successfully by suture and one transient ischaemic attack without permanent sequelae. Late complications involved one massive pulmonary embolization and an atrioesophageal fistula. There was no periprocedural myocardial infarction or stroke with permanent sequelae. CONCLUSION: Hybrid thoracoscopic-catheter ablation performed during one procedure is an effective and relatively safe mini-invasive method of treatment for long-term persistent atrial fibrillation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Fatores de Tempo , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
2.
Europace ; 24(10): 1636-1644, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35979596

RESUMO

AIMS: Interventional cardiology procedures may expose patients and staff to considerable radiation doses. We aimed to assess whether exposure to ionizing radiation during catheter ablation of supraventricular tachycardia (SVT) can be completely avoided. METHODS AND RESULTS: In this prospective randomized study, patients with SVT (atrioventricular re-entrant tachycardia n = 94, typical atrial flutter n = 29) were randomly assigned in a 1:1 ratio to catheter ablation with conventional fluoroscopic guidance (CF group) or with the EnSite Precision mapping system [zerofluoro (ZF) group]. Acute procedural parameters, increased stochastic risk of cancer incidence and 6-month follow-up data were assessed. Between May 2019 and August 2020, 123 patients were enrolled. Clinical parameters were comparable. Median procedural time was 60.0 and 58.0 min, median fluoroscopy time and estimated median effective dose were 240 s vs. 0 and 0.38 mSv vs. 0 and arrhythmia recurrence was 5% and 7.9% in the CF and ZF groups, respectively. The acute success rate was 98.4% in both groups. No procedure-related complications were reported. At an average age of 55.5 years and median radiation exposure of 0.38 mSv, the estimate of increased incidence was approximately 1 in 14 084. The estimated mortality rate was 1 per 17 857 exposed persons. CONCLUSIONS: The procedural safety and efficacy of the zero-fluoroscopic approach are similar to those of conventional fluoroscopy-based ablation for atrioventricular nodal re-entrant tachycardia and atrial flutter. Under the assumption of low radiation dose, the excessive lifetime risk of malignancy in the CF group due to electrophysiology procedure is reasonably small, whilst totally reduced in zero fluoroscopy procedures.


Assuntos
Flutter Atrial , Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Supraventricular , Arritmias Cardíacas/cirurgia , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Nó Atrioventricular , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fluoroscopia/métodos , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico por imagem , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
3.
Diagnostics (Basel) ; 12(3)2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35328165

RESUMO

(1) Background: Computer tomography (CT) is an imaging modality used in the pre-planning of radiofrequency catheter ablation (RFA) procedure in patients with cardiac arrhythmias. However, it is associated with a considerable ionizing radiation dose for patients. This study aims to develop and validate low-dose CT scanning protocols of the left atrium (LA) for RFA guidance. (2) Methods: 68 patients scheduled for RFA of atrial fibrillation were sequentially assigned to four groups of ECG-gated scanning protocols, based on the set tube current (TC): Group A (n = 20, TC = 33 mAs), Group B (n = 18, TC = 67 mAs), Group C (n = 10, TC = 135 mAs), and control Group D (n = 20, TC = 600 mAs). We used a 256-row multidetector CT with body weight-dependent tube voltage of 80 kVp (<70 kg), 100 kVp (70−90 kg), and 120 kVp (>90 kg). We evaluated scanning parameters including radiation dose, total scanning procedure time and signal-to-noise ratio (SNR). (3) Results: The average effective radiation dose (ED) was lower in Group A in comparison to Group B, C and D (0.83 (0.76−1.10), 1.55 (1.36−1.67), 2.91 (2.32−2.96) and 9.35 (8.00−10.04) mSv, p < 0.05). The total amount of contrast media was not significantly different between groups. The mean SNR was 6.5 (5.8−7.3), 7.1 (5.7−8.2), 10.8 (10.1−11.3), and 12.2 (9.9−15.7) for Group A, B, C and D, respectively. The comparisons of SNR in group A vs. B and C vs. D were without significant differences. (4) Conclusions: Optimized pre-ablation CT scanning protocols of the LA can reduce an average ED by 88.7%. Three dimensional (3D) models created with the lowest radiation protocol are useful for the integration of electro-anatomic-guided RFA procedures.

4.
J Interv Card Electrophysiol ; 64(2): 375-381, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34089431

RESUMO

BACKGROUND AND PURPOSE: Saline-irrigated radiofrequency ablation (RFA) for atrial fibrillation (AF) is limited by the absence of reliable thermal feedback limiting the utility of temperature monitoring for power titration. The DiamondTemp (DT) ablation catheter was designed to allow efficient temperature-controlled irrigated ablation. We sought to assess the 1-year clinical safety and efficacy of the DT catheter in treating drug-refractory paroxysmal AF. METHODS: The TRAC-AF trial (NCT02821351) is a prospective, multi-center (n = 4), single-arm study which enrolled patients with symptomatic, drug-refractory, paroxysmal AF. Using the DT catheter, point-by-point ablation was performed around all pulmonary veins (PVs) to achieve PV isolation (PVI). Ablation was performed in a temperature-controlled mode (60 °C, max 50 W). Acute and chronic efficacy and safety was evaluated. RESULTS: Seventy-one patients (age 69.9 ± 11.0 years; 60.6% male) were ablated using the DT catheter. The mean fluoroscopy and RF ablation times were 9.3 ± 6.1 min and 20.6 ± 8.9 min, respectively. Acute isolation of all PVs was achieved in 100% of patients, and freedom from AF after 1 year was 70.6%. There were no steam pops, char, or coagulum on the catheter tip after ablation. There were few serious procedure/device-related adverse events including a single case of cardiac tamponade (1.4%) and transient ischemic attack (1.4). CONCLUSION: This first in man series demonstrates that temperature-controlled irrigated RFA with the DT catheter is efficient, safe, and effective in the treatment of paroxysmal AF. Randomized controlled trials are ongoing and will evaluate better the role of this catheter in relation to standard RFA. TRIAL REGISTRATION: Registered on the site ClinicalTrials.gov January 2016 with identifier: NCT02821351.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/cirurgia , Temperatura , Resultado do Tratamento
5.
Card Electrophysiol Clin ; 13(2): 399-408, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33990278

RESUMO

Intracardiac echocardiography (ICE) is the most practical method for online imaging during electrophysiological procedures. It allows guiding of complex catheter ablation procedures together with electroanatomical mapping systems, either with minimal or with zero fluoroscopy exposure. Besides safe and reproducible transseptal puncture, ICE helps to assess location and contact of the tip of the ablation catheter relative to specific anatomical structures. Another option is visualization of the arrhythmogenic substrate in patients with ventricular arrhythmias. This article describes the clinical utility of ICE in non-fluoroscopic electrophysiology procedures more in detail.


Assuntos
Ecocardiografia/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/cirurgia , Ablação por Cateter/métodos , Fluoroscopia , Coração/diagnóstico por imagem , Humanos , Cirurgia Assistida por Computador/métodos
6.
J Cardiovasc Electrophysiol ; 31(5): 1128-1136, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32083360

RESUMO

INTRODUCTION: Despite technical progress, ventricular tachycardia (VT) recurrence after unipolar ablation remains relatively high (12%-47%). Bipolar ablation has been proposed as an appealing solution that may overcome limitations associated with unipolar ablation settings. We designed an animal study to compare bipolar (BPA) vs sequential unipolar ablation (UPA) using contact force-sensing technology on both ablation catheters. METHODS: Twenty large white female pigs (6-months-old, 50-60 kg) underwent multiple RF ablations (30 W, 60 seconds, 30 mL/min irrigation) on the ventricular myocardium from the epicardial and endocardial sides. The hearts were fixed and scanned with high-resolution cardiac magnetic resonance imaging. Thermal lesions were located and characterized in volume, depth, width, and transmurality. RESULTS: Lesion volume was calculated as the sum of epicardial or endocardial conjoined/isolated lesions at one location. Linear dimensions (width and depth) were measured twice for each location, on the endocardial and epicardial side. We evaluated 35 lesions across the intraventricular septum (UPA, N = 17 vs BPA, N = 18). No difference in volume, linear dimensions or impedance drop was observed in this area between UPA and BPA. However, BPA required half RF time and showed an increased transmurality trend. We then analyzed 73 lesions from the endocardial side (UPA, N = 35 vs BPA, N = 38) and 50 from the epicardial side (UPA, N = 11 vs BPA N = 39) of the ventricular free walls. Lesion transmurality was markedly improved by BPA (P = .030, odds ratio, 23.73 [4.71,31.96]). Ventricular BPA lesions were significantly deeper on the epicardial side (P < .0001) and endocardial side (P = .015). CONCLUSION: Bipolar ablation is more likely to create transmural and epicardial lesions in the ventricle wall. Half the time is needed for the creation of comparably deep and large lesions.


Assuntos
Cateteres Cardíacos , Ablação por Cateter/instrumentação , Ventrículos do Coração/cirurgia , Miocárdio/patologia , Transdutores de Pressão , Animais , Ablação por Cateter/efeitos adversos , Desenho de Equipamento , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Imageamento por Ressonância Magnética , Sus scrofa
7.
Artigo em Inglês | MEDLINE | ID: mdl-31645769

RESUMO

AIMS: This study aims to compare procedural parameters and clinical efficacy of remote magnetic navigation (RMN) vs. manual navigation (MAN) approach for radiofrequency ablation (RFA) in patients with atrial fibrillation (AF). METHODS: 146 patients with AF were enrolled in the study. In the RMN group (n=57), patients were treated with the CARTO® 3 in combination with the Niobe ES system. In the MAN group (n=89), ablation was performed with the EnSite Velocity and TactiCath™ Quartz catheter with direct contact force measurement. Procedural time, ablation time, fluoroscopy time, radiation dose and ablation counts were measured and compared between the groups. Recurrence of AF was evaluated after 6 months of follow-up. RESULTS: Mean procedure times (236.87±64.31 vs. 147.22±45.19 min, P<0.05), counts of RF applications (74.30±24.77 vs. 49.15±20.33, P<0.05) and total RFA times (4323.39±1426.69 vs. 2780.53±1157.85 s, P<0.05) were all significantly higher in the RMN than in the MAN group, respectively. In the same order, mean X-ray dose (9722.6±7507.4 vs. 8087.9±6051.5 mGy/cm2, P=0.12) and mean total X-ray exposure time (8.07±4.20 vs. 9.54±5.47 min, P=0.08) were not statistically different. At 6-month follow-up, freedom from AF was similar in RMN and MAN group for paroxysmal (60.8% and 73%, respectively, P=0.42) and persistent AF (69.6% and 75.0%, respectively, P=0.77). CONCLUSIONS: Due to the fact that mid-term clinical outcomes showed no significant differences in AF recurrences between groups and manual ablation strategy provided more favorable results regarding acute procedural parameters, we can conclude that the remote magnetic navigation is not superior to the manual approach.


Assuntos
Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas/métodos , Técnicas Eletrofisiológicas Cardíacas/estatística & dados numéricos , Ablação por Radiofrequência/métodos , Ablação por Radiofrequência/estatística & dados numéricos , Sistemas de Navegação Cirúrgica/estatística & dados numéricos , Resultado do Tratamento , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
Indian Heart J ; 70(1): 37-44, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29455785

RESUMO

AIMS: Three-dimensional rotational angiography (3DRA) of the left atrium (LA) and the esophagus is a simple and safe method for analyzing the relationship between the esophagus and the LA during catheter ablation of atrial fibrillation. The purpose of this study is to describe the location of the esophagus relative to the LA and mobility of the esophagus during ablation procedure. METHODS: From 3/2011 to 9/2015, 3DRA of the LA and esophagus was performed in 326 patients before catheter ablation of atrial fibrillation. 3DRAwas performed with visualization of the esophagus via peroral administration of a contrast agent. The positions of the esophagus were determined at the beginning of the procedure, for part of patients also at the end of procedure with contrast esophagography. RESULTS: The most frequent position is behind the center of the LA (91 pts., 31.9%) The least frequent position is behind the right pulmonary veins (27 pts., 9.4%). The average shift of the esophagus position was 3.36±2.15mm, 3.59±2.37mm and 3.67±3.23mm for superior, middle and inferior segment resp. CONCLUSIONS: The position of the esophagus to the LA is highly variable. The most common position of the esophagus relative to the LA is behind the middle and left part of the posterior wall of the LA. The least frequently observed position is behind the right pulmonary veins. No significant position change of esophagus motion from before to after the ablation procedure in the majority (≥95%) of the patients was observed.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Angiografia por Tomografia Computadorizada/métodos , Esôfago/diagnóstico por imagem , Fluoroscopia/métodos , Imageamento Tridimensional/métodos , Cirurgia Assistida por Computador/métodos , Fibrilação Atrial/diagnóstico , Feminino , Átrios do Coração/diagnóstico por imagem , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
10.
JACC Clin Electrophysiol ; 3(7): 747-755, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28736750

RESUMO

INTRODUCTION: Epicardial defibrillation systems currently require surgical access. We aimed to develop a percutaneous defibrillation system with partially-insulated epicardial coils to focus electrical energy on the myocardium and prevent or minimize extra-cardiac stimulation. METHODS: We tested 2 prototypes created for percutaneous introduction into the pericardial space via a steerable sheath. This included a partially-insulated defibrillation coil and a defibrillation mesh with a urethane balloon acting as an insulator to the face of the mesh not in contact with the epicardium. The average energy associated with a chance of successful defibrillation 75% of the time (ED75) was calculated for each experiment. RESULTS: Of 16 animal experiments, 3 pig experiments had malfunctioning mesh prototypes such that results were unreliable; these were excluded. Therefore, 13 animal experiments were analyzed - 6 canines (29.8±4.0kg); 7 pigs (41.1±4.4kg). The overall ED75 was 12.8±6.7J (10.9±9.1J for canines; 14.4±3.9J in pigs [P=0.37]). The lowest ED75 obtained in canines was 2.5J while in pigs it was 9.5J. The lowest energy resulting in successful defibrillation was 2J in canines and 5J in pigs. There was no evidence of coronary vessel injury or trauma to extra-pericardial structures. CONCLUSION: Percutaneous, epicardial defibrillation using a partially insulated coil is feasible and appears to be associated with low defibrillation thresholds. Focusing insulation may limit extra-cardiac stimulation and potentially lower energy requirements for efficient defibrillation.


Assuntos
Desfibriladores , Animais , Cães , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/métodos , Feminino , Masculino , Pericárdio , Suínos
11.
J Card Fail ; 23(7): 558-562, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28408305

RESUMO

BACKGROUND: Patients with atrial fibrillation (AF) have an increased risk of diastolic dysfunction and heart failure. The purpose of this study was to identify independent predictors of early (ie, only exercise-induced) heart failure with preserved ejection fraction (HFpEF) and to describe the prevalence of early HFpEF among patients with paroxysmal AF. METHODS AND RESULTS: One hundred patients with paroxysmal AF and preserved left ventricular ejection fraction (LVEF) underwent catheterization for left atrial pressure (LAP) measurements at rest and at the peak of arm exercise (LAP-exe). Based on resting and exercise LAP values, the patients were divided into 3 groups. Sixty-one patients had no evidence of HFpEF (LAP at rest ≤15 mm Hg, LAP-exe <25 mm Hg). Twenty-five subjects had early HFpEF (LAP at rest ≤15 mm Hg, LAP-exe ≥25 mm Hg, prevalence 25%). Fourteen patients already had HFpEF at rest (LAP at rest >15 mm Hg). Multivariate exact logistic regression analysis identified age ≥58 years, LAP at rest ≥11 mm Hg, and peak systolic mitral annular velocity ≤9.3 cm/s to be independent predictors of early HFpEF. CONCLUSIONS: In patients with paroxysmal AF and preserved LVEF, there appears to be a clinically significant prevalence of early HFpEF.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/epidemiologia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/epidemiologia , Volume Sistólico/fisiologia , Idoso , Fibrilação Atrial/fisiopatologia , Estudos de Coortes , Diagnóstico Precoce , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Estudos Prospectivos
12.
Echocardiography ; 34(1): 78-86, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27779336

RESUMO

BACKGROUND: Noninvasive diagnosis of exercise-induced elevation of left ventricular filling pressure is difficult and remains unsatisfactory. The aim of this study was to assess the accuracy of the ratio of early diastolic transmitral (E) to mitral annular (e') velocity and to determine new parameters or parameter combinations with the ability to predict exercise-induced left atrial pressure (LAP) elevation. METHODS AND RESULTS: Eighty patients with paroxysmal atrial fibrillation (AF) referred for catheter AF ablation underwent simultaneous exercise echocardiography and direct invasive LAP measurements, as well as a resting and postexercise biomarker analysis. Exercise E/e' ≥8.85 predicted exercise LAP ≥20 mm Hg with 61.5% sensitivity and 88.9% specificity (area under the curve [AUC], 0.76). Of all of the individual parameters tested, the best prediction was achieved with exercise E/s' (s'=peak systolic mitral annular velocity) ≥8.75 (sensitivity, 88.5%; specificity, 64.8%; positive predictive value, 54.8%; negative predictive value, 92.1%; AUC, 0.84). However, the combination of exercise E/A (A = late diastolic transmitral flow velocity) ≥1.22 + exercise E/e' ≥8.85 + exercise s'≤11.05 cm/s provided the most precise prediction of exercise LAP elevation (sensitivity, 84.6%; specificity, 79.6%; positive predictive value, 66.7%; negative predictive value, 91.5%; AUC, 0.90). CONCLUSIONS: Exercise E/e', when used as a sole parameter, was not sufficiently reliable to predict exercise-induced elevation of LAP. The application of a multivariate-adjusted combination of parameters appeared to be the preferable approach for the noninvasive prediction of exercise LAP elevation.


Assuntos
Ecocardiografia/métodos , Exercício Físico/fisiologia , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Pressão Ventricular/fisiologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Velocidade do Fluxo Sanguíneo , Diástole , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sístole
13.
Europace ; 19(8): 1310-1316, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27915264

RESUMO

AIMS: The objective of this study was to evaluate the mobility of the oesophagus and the stability of the three-dimensional (3D) model of the oesophagus using 3D rotational angiography (3DRA) of the left atrium (LA) and the oesophagus, fused with live fluoroscopy during catheter ablation for atrial fibrillation. METHODS AND RESULTS: From March 2015 to September 2015, 3DRA of the LA and the oesophagus was performed in 33 patients before catheter ablation for atrial fibrillation. Control contrast oesophagography was performed every 30 min. The positions of the oesophagograms and the 3D model of the LA and the oesophagus were repeatedly measured and compared with the spine. The average shift of the oesophagus ranged from 2.7 ± 2.2 to 5.0 ± 3.5 mm. The average real-time oesophageal shift ranged from 2.7 ± 2.2 to 3.8 ± 3.4 mm. No significant shift was detected until the 90th minute of the procedure. The average shift of the 3D model of the LA and the oesophagus ranged from 1.4 ± 1.8 to 3.3 ± 3.0 mm (right-left direction) and from 0.9 ± 1.2 to 2.2 ± 1.3 mm (craniocaudal direction). During the 2 h procedure, there were no significant shifts of the model. CONCLUSION: During catheter ablation for atrial fibrillation, there is no significant change in the position of the oesophagus until the 90th minute of the procedure and no significant shift in the 3D model of the LA and the oesophagus. The 3D model of the oesophagus reliably depicts the position of the oesophagus during the entire procedure.


Assuntos
Angiografia/métodos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Esôfago/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Imageamento Tridimensional , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Intervencionista/métodos , Cirurgia Assistida por Computador/métodos , Idoso , Pontos de Referência Anatômicos , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Fluoroscopia , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Duração da Cirurgia , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Cirurgia Assistida por Computador/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
14.
Int J Cardiovasc Imaging ; 32(7): 1011-9, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27116237

RESUMO

A new method in creating 3D models of the left atrium (LA) and esophagus before catheter ablation of atrial arrhythmias is 3D rotational angiography (3DRA) of the LA. The purpose of this retrospective study was to test various acquisition protocols of the 3DRA and attempt to define the parameters influencing the success of the protocols. From August 2010 to November 2014, 3DRA of the LA using the Philips Allura FD 10 X-ray system was performed in 547 consecutive patients using right atrial and left atrial protocols. Visualization of the esophagus was performed after oral administration of a contrast agent. Patients were monitored for success (creation of a useful 3D models) and evaluated for a number of parameters affecting the success of 3DRA. The success of the RA protocol was 88.89 % with and 91.91 % without esophagus imaging. The success of the LA protocol was 97.42 % with and 94.54 % without esophagus imaging. The only factor reducing the success of the RA protocol was BMI; the LA protocol was not influenced by any factor. Ventricular fibrillation induced in two patients was successfully treated with defibrillation. 3DRA of the LA is a reliable method that supports catheter ablation of complex atrial arrhythmias. The LA protocol with esophagus imaging was significantly more reliable than the RA protocol; the other protocols were comparable. The RA protocol may be negatively affected by high BMI. Simultaneous imaging of the esophagus is safe and feasible, and the LA protocol can be recommended.


Assuntos
Angiografia/métodos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter , Esôfago/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Imageamento Tridimensional , Interpretação de Imagem Radiográfica Assistida por Computador , Idoso , Fibrilação Atrial/fisiopatologia , Índice de Massa Corporal , Simulação por Computador , Meios de Contraste/administração & dosagem , Feminino , Átrios do Coração/fisiopatologia , Humanos , Iohexol/administração & dosagem , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos
15.
J Interv Card Electrophysiol ; 46(2): 81-7, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26971333

RESUMO

PURPOSE: Computed tomography (CT) and 3D rotational angiography (3DRA) of the left atrium (LA) are used to evaluate the esophagus prior to radiofrequency ablation for atrial fibrillation. The aim of this study was to compare preprocedural and periprocedural views of the esophagus and the left atrium. METHODS: From September 2011 to August 2012, 3DRA and CT of the LA were performed on 56 patients before they underwent catheter ablation of atrial fibrillation. The 3DRA was performed periprocedurally, and the CT was performed an average of 20 days prior to the procedure. 3D models of the LA and the esophagus were then segmented on the EP Navigator V 3.1 workstation. Five positions of the esophagus, A-E, in order from left to right, were evaluated. RESULTS: The most common position of the esophagus was behind the left part of the LA (CT, position B (n = 26)) and behind the central part of the LA (3DRA, position C (n = 21)). The maximum shift of the esophagus was three positions, and the average shift was 0.857 ± 0.766 of a position. There was a shift of one position in 44.6 % of the patients, two positions in 17.9 %, and three positions in 1.8 %. A statistically significant difference was found between the positions of the esophagus when the 3DRA and CT evaluations were compared. CONCLUSIONS: The most common position of the esophagus was behind the middle and left part of the LA. The outpatient views of the esophagus obtained before ablation did not reflect the position of the esophagus at the beginning of the procedure.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter , Esôfago/diagnóstico por imagem , Imageamento Tridimensional , Cirurgia Assistida por Computador , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Esôfago/cirurgia , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Cuidados Pós-Operatórios , Cuidados Pré-Operatórios , Reprodutibilidade dos Testes , Estudos Retrospectivos , Rotação , Sensibilidade e Especificidade , Resultado do Tratamento
16.
Int J Cardiovasc Imaging ; 31(5): 899-904, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25761532

RESUMO

Three-dimensional rotational angiography (3 DRA) is a novel imaging method introduced to guide complex catheter ablations of the left atrium. Our aim was to investigate the feasibility of the method in visualization of left ventricular anatomy and to develop a corresponding protocol for guidance of ventricular tachycardia ablation. We performed 3D rotational angiography in 13 patients using a direct left atrial protocol for data acquisition and the 3D reconstruction of the left ventricle was achieved in all patients. Clinical data comparison has proved lower use of radiation and contrast medium during 3 DRA-guided ablations as compared to CT-guided procedures.


Assuntos
Ablação por Cateter , Angiografia Coronária/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Radiografia Intervencionista/métodos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Idoso , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Resultado do Tratamento
17.
Curr Cardiol Rev ; 11(2): 167-79, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25028165

RESUMO

Atrial fibrillation is the most common sustained arrhythmia. Because of the sub-optimal outcomes and associated risks of medical therapy as well as the recent advances in non-pharmacologic strategies, a multitude of combined (hybrid) algorithms have been introduced that improve efficacy of standalone therapies while maintaining a high safety profile. Antiarrhythmic administration enhances success rate of electrical cardioversion. Catheter ablation of antiarrhythmic drug-induced typical atrial flutter may prevent recurrent atrial fibrillation. Through simple ablation in the right atrium, suppression of atrial fibrillation may be achieved in patients with previously ineffective antiarrhythmic therapy. Efficacy of complex catheter ablation in the left atrium is improved with antiarrhythmic drugs. Catheter ablation followed by permanent pacemaker implantation is an effective and safe treatment option for selected patients. Additional strategies include pacing therapies such as atrial pacing with permanent pacemakers, preventive pacing algorithms, and/or implantable dual-chamber defibrillators are available. Modern hybrid strategies combining both epicardial and endocardial approaches in order to create a complex set of radiofrequency lesions in the left atrium have demonstrated a high rate of success and warrant further research. Hybrid therapy for atrial fibrillation reviews history of development of non-pharmacological treatment strategies and outlines avenues of ongoing research in this field.


Assuntos
Fibrilação Atrial/terapia , Animais , Antiarrítmicos/uso terapêutico , Flutter Atrial/tratamento farmacológico , Estimulação Cardíaca Artificial , Ablação por Cateter , Terapia Combinada , Humanos
18.
Artigo em Inglês | MEDLINE | ID: mdl-25030605

RESUMO

BACKGROUND: Catheter ablation in the left atrium has become a common therapeutic strategy in the management of atrial fibrillation (AF). The high degree of success and safety profile of this procedure is dependent on precise knowledge of the true anatomy in the chamber. This information is imported mostly from cardiac computed tomography. A novel method for imaging the left atrial anatomy is three-dimensional rotational angiography (3DRA). METHODS: The aim of our study was to the compare clinical outcome and safety of catheter ablation for atrial fibrillation guided by 3DRA vs. conventional CT scan. One hundred and twenty-five patients referred for AF catheter ablation at St. Anne's University Hospital Brno were included in the retrospective analysis of clinical outcome within the first year after the procedure. RESULTS: There was a close correlation in overall procedural parameters between the groups. The frequency of recurrent episodes of AF (24% in CT-guided group vs. 27% in 3DRA-guided group, P=0.721) as well as the onset of atypical atrial flutter after the procedure (10% vs. 8%, respectively, P=0.731) were similar in both groups. No difference in the number of patients necessitating repeat ablation (5% vs. 5%, P=0.984) was found. Procedural complications of ablations guided by 3DRA were comparable with those guided by CT (2% vs. 3%, respectively, P=0.568). CONCLUSION: 3DRA has proven to be a safe and simple method for imaging the left atrium and guiding catheter ablation for AF. This approach is anticipated to become a new standard in 3D reconstruction of the left atrium.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Angiografia/métodos , Fibrilação Atrial/diagnóstico por imagem , Ablação por Cateter/efeitos adversos , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Veias Pulmonares/diagnóstico por imagem , Radiografia Intervencionista/métodos , Recidiva , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
19.
Int J Cardiovasc Imaging ; 30(7): 1207-23, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24964905

RESUMO

Cardiac arrhythmias are a very frequent illness. Pharmacotherapy is not very effective in persistent arrhythmias and brings along a number of risks. Catheter ablation has became an effective and curative treatment method over the past 20 years. To support complex arrhythmia ablations, the 3D X-ray cardiac cavities imaging is used, most frequently the 3D reconstruction of CT images. The 3D cardiac rotational angiography (3DRA) represents a modern method enabling to create CT like 3D images on a standard X-ray machine equipped with special software. Its advantage lies in the possibility to obtain images during the procedure, decreased radiation dose and reduction of amount of the contrast agent. The left atrium model is the one most frequently used for complex atrial arrhythmia ablations, particularly for atrial fibrillation. CT data allow for creation and segmentation of 3D models of all cardiac cavities. Recently, a research has been made proving the use of 3DRA to create 3D models of other cardiac (right ventricle, left ventricle, aorta) and non-cardiac structures (oesophagus). They can be used during catheter ablation of complex arrhythmias to improve orientation during the construction of 3D electroanatomic maps, directly fused with 3D electroanatomic systems and/or fused with fluoroscopy. An intensive development in the 3D model creation and use has taken place over the past years and they became routinely used during catheter ablations of arrhythmias, mainly atrial fibrillation ablation procedures. Further development may be anticipated in the future in both the creation and use of these models.


Assuntos
Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/cirurgia , Ablação por Cateter/métodos , Angiografia Coronária/métodos , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/cirurgia , Imageamento Tridimensional , Tomografia Computadorizada Multidetectores/métodos , Interpretação de Imagem Radiográfica Assistida por Computador , Potenciais de Ação , Animais , Arritmias Cardíacas/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Valor Preditivo dos Testes , Radiografia Intervencionista , Software , Cirurgia Assistida por Computador
20.
Am J Cardiol ; 105(11): 1597-602, 2010 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-20494669

RESUMO

The aim of this study was to investigate whether patients with hypertrophic cardiomyopathy (HC) and sleep disordered breathing (SDB) have a higher prevalence of atrial fibrillation (AF) compared to patients with HC without SDB. HC is associated with a high prevalence of AF that contributes to increased morbidity and mortality. SDB is strongly associated with a higher incidence, prevalence, and recurrence of AF in patients without HC. Whether this association also applies to patients with HC is not known. Overnight oximetry was prospectively performed on 91 consecutive patients with echocardiographically confirmed HC. The presence or absence of AF in this population was correlated with the oximetric findings. SDB was associated with a higher prevalence of AF (40% vs 11%, p = 0.005). In addition, SDB was accompanied by significantly increased left atrial volume index (58 +/- 19 vs 42 +/- 13 ml/m(2), p = 0.0002). Increasing severity of SDB was correlated with higher AF prevalence and with increase in left atrial volume index. These associations remained significant even after accounting for potential confounders in a multivariate analysis. In conclusion, these findings suggest that the presence and severity of SDB may influence left atrial volume index and the prevalence of AF in patients with HC. SDB may therefore be an important and potentially modifiable cause of morbidity and mortality in this population.


Assuntos
Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/fisiopatologia , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/fisiopatologia , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/epidemiologia , Eletrocardiografia , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Minnesota/epidemiologia , Oximetria/métodos , Prevalência , Estudos Prospectivos , Recidiva , Índice de Gravidade de Doença , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...