Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 14(11)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38893703

RESUMO

INTRODUCTION: The scapholunate interosseous ligament is pivotal for wrist stability, and its impairment can result in instability and joint degeneration. This study explores the application of real-time MRI for dynamic assessment of the scapholunate joint during wrist motion with the objective of determining its diagnostic value in efficacy in contrast to static imaging modalities. MATERIALS AND METHODS: Ten healthy participants underwent real-time MRI scans during wrist ab/adduction and fist-clenching maneuvers. Measurements were obtained at proximal, medial, and distal landmarks on both dynamic and static images with statistical analyses conducted to evaluate the reliability of measurements at each landmark and the concordance between dynamic measurements and established static images. Additionally, inter- and intraobserver variabilities were evaluated. RESULTS: Measurements of the medial landmarks demonstrated the closest agreement with static images and exhibited the least scatter. Distal landmark measurements showed a similar level of agreement but with increased scatter. Proximal landmark measurements displayed substantial deviation, which was accompanied by an even greater degree of scatter. Although no significant differences were observed between the ab/adduction and fist-clenching maneuvers, both inter- and intraobserver variabilities were significant across all measurements. CONCLUSIONS: This study highlights the potential of real-time MRI in the dynamic assessment of the scapholunate joint particularly at the medial landmark. Despite promising results, challenges such as measurement variability need to be addressed. Standardization and integration with advanced image processing methods could significantly enhance the accuracy and reliability of real-time MRI, paving the way for its clinical implementation in dynamic wrist imaging studies.

2.
Case Rep Nephrol Dial ; 12(3): 145-149, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36518357

RESUMO

In parallel with the decline of renal excretory function, drug dosing of many drugs becomes more challenging. Finding the right dose is even more difficult if kidney replacement therapy is instituted. This is further aggravated by the fact that even for substances with a narrow therapeutic range, drug monitoring is only rarely offered, let alone advocated. This holds also true for gabapentin, an anticonvulsant drug that is increasingly prescribed for indications such as cancer-related pain, restless legs syndrome, migraine, or uremic pruritus. The drug is excreted unchanged in urine, so plasma clearance of gabapentin is directly proportional to creatinine clearance. Hence, renal impairment reduces gabapentin excretion and increases plasma gabapentin concentrations in a linear fashion. Therefore, the elimination half-life of gabapentin is between 5 and 9 h, in patients with normal renal function but increases to 132 h in patients on dialysis. Epidemiological data from the USRDS underline this problem. About 19% of the 140,899 adult USA patients enrolled in Medicare coverage received gabapentin in 2011. Its use was associated with an increased risk of altered mental status, fall, and fracture. We report 2 patients in which overdose of gabapentin occurred. In 1 patient, severe neurological symptoms prompted an extensive diagnostic work up, while the underlying cause of the clinical presentation was a supra-therapeutic drug level of gabapentin. Consequently, symptoms subsided with the discontinuation of the drug. Indication and drug dose of gabapentin in dialysis patients should be tightly controlled, and drug monitoring used to avoid unintended overdose.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...