Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Vascular ; 25(2): 115-122, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27381926

RESUMO

Introduction The office-based endovascular facility has increased in number recently due in part to expedient patient experience. This study analyzed treatment outcomes of procedures performed in our office-based endovascular suite. Methods Treatment outcomes of 5134 consecutive procedures performed in our office-based endovascular suites from 2006 to 2013 were analyzed. Five sequential groups (group I-V) of 1000 consecutive interventions were compared with regard to technical success and treatment outcomes. Results Our patients included 2856 (56%) females and 2267 (44%) males. Procedures performed included diagnostic arteriogram, arterial interventions, venous interventions, dialysis access interventions, and venous catheter management, which were 1024 (19.9%), 1568 (30.6%), and 3073 (60.0%), 621(12.1%), and 354 (6.9%), respectively. The complication rates for group I, II, III, IV, and V were 3%, 1.5%, 1%, 1.1%, and 0.7%, respectively. The complication rate was higher in group I when compared to each of the remaining four groups ( p < 0.05). Nine patients (0.18%) died within the 30-day period following their procedures, and none were procedure related. Conclusions Endovascular procedure can be performed safely in an office-based facility with excellent outcomes. Lessons learned in establishing office-based endovascular suites with efforts to reduce procedural complications and optimize quality patient care are discussed.


Assuntos
Procedimentos Cirúrgicos Ambulatórios , Angiografia , Procedimentos Endovasculares , Visita a Consultório Médico , Avaliação de Processos em Cuidados de Saúde , Radiografia Intervencionista , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Ambulatórios/efeitos adversos , Angiografia/efeitos adversos , Cateterismo Venoso Central , Diálise , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Complicações Pós-Operatórias/etiologia , Valor Preditivo dos Testes , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Stents , Texas , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
2.
J Vasc Surg ; 40(1): 146-53, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15218475

RESUMO

PURPOSE: Current strategies to create small-diameter vascular grafts involve seeding biocompatible, compliant scaffolds with autologous vascular cells. Our purpose was to study the composition and strength of decellularized vein to determine its potential as a vascular tissue-engineering scaffold. METHODS: Intact human greater saphenous vein specimens were decellularized by using sodium dodecyl sulfate (SDS). Residual cellular and extracellular matrix composition was studied with light and electron microscopy as well as immunohistochemistry. Burst and suture-holding strength was measured in vitro by insufflation and pull-through techniques. To assess initial handling and durability of decellularized vein in vivo, a canine model was developed wherein decellularized canine jugular veins were implanted as carotid interposition grafts in recipient animals. After two weeks of arterial perfusion, these grafts were studied with duplex imaging and histologic methods. RESULTS: Human saphenous vein decellularized by using SDS was devoid of endothelial cells and >94% of the cells resident within the vein wall. Collagen morphology appeared unchanged, and elastin staining decreased only slightly. Basement membrane collagen type IV remained intact. Compared with fresh vein, decellularized vein had similar in vitro burst (2480 +/- 460 mm Hg vs 2380 +/- 620 mm Hg; P >.05) and suture-holding (185 +/- 30 gm vs 178 +/- 66 gm; P >.05) strength. Decellularized canine vein functioned well in vivo without dilation, anastomotic complication, or rupture over 2 weeks of arterial perfusion. CONCLUSIONS: Vein rendered acellular with SDS has well-preserved extracellular matrix, basement membrane structure, and strength sufficient for vascular grafting. These properties suggest proof of concept for its use as a scaffold for further vascular tissue engineering. CLINICAL RELEVANCE: The following research examines the creation of a new small-diameter bypass graft. It is clinically relevant to patients who need distal arterial bypass, coronary artery bypass, or hemodialysis access, but who do not have adequate autologous vein for their surgeries. Future investigations will involve further tissue engineering of this vascular scaffold (eg, autologous endothelial seeding of its lumen) and testing the clinical usefulness of the completed graft.


Assuntos
Prótese Vascular , Veia Safena/efeitos dos fármacos , Engenharia Tecidual/métodos , Antígenos de Superfície/farmacologia , Matriz Extracelular/efeitos dos fármacos , Humanos , Veia Safena/fisiopatologia , Dodecilsulfato de Sódio/farmacologia
3.
J Vasc Surg ; 35(4): 805-7, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11932684

RESUMO

A postoperative superior mesenteric artery pseudoaneurysm that communicates with a pancreatic pseudocyst after aortic surgery is a difficult management problem. Untreated, this condition can lead to exsanguination. Traditional surgical treatment has many potential complications. Endovascular repair has the potential for avoidance of surgical complications. We present the first superior mesenteric artery pseudoaneurysm successfully treated with A polytetrafluorethylene covered stent.


Assuntos
Falso Aneurisma/terapia , Oclusão Vascular Mesentérica/terapia , Politetrafluoretileno , Stents , Falso Aneurisma/complicações , Falso Aneurisma/diagnóstico por imagem , Humanos , Masculino , Artéria Mesentérica Superior , Oclusão Vascular Mesentérica/complicações , Oclusão Vascular Mesentérica/diagnóstico por imagem , Pessoa de Meia-Idade , Pseudocisto Pancreático/complicações , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA