1.
PLoS One ; 15(3): e0230027, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32150598

RESUMO

BACKGROUND: We described safety and functional one-year follow-up outcomes of individuals with lower limb amputation treated with bone-anchored prostheses using titanium press-fit osseointegration implants. METHODS: All consecutive individuals treated between March 2015 and June 2018 with curved osseointegration femur implant (OFI-C) indicated for a long femoral remnant, gamma osseointegration femur implant (OFI-Y) indicated for a short femoral remnant, or osseointegration tibia implant (OTI) were eligible for this study. All adverse events were evaluated, infections were graded as follows: grade 1 and 2: low- and high-grade soft tissue infection, respectively, grade 3: deep bone infection, grade 4: septic implant failure. Functional outcome measures included prosthesis wearing time (PUS), health-related quality of life (GS), and the overall situation as an amputee (GS Q3); evaluated with the Questionnaire of persons with trans-femoral amputation (Q-TFA) before surgery and at one-year follow-up. RESULTS: Ninety of 91 individuals were included (mean age: 54±14 yrs, 26 females); treated with 53, 16 and 21 OFI-C, OFI-Y and OTI, respectively. Soft tissue infections (grade 1: 11 events, grade 2: 10 events) were treated successfully with antibiotics except in two (OFI-C and OFI-Y), who required additional surgery due to recurrent stoma irritation and peri-stoma abscess drainage. One individual with dysvascular amputation (OTI) developed septic implant loosening and occlusion of the femoral artery resulting in a transfemoral amputation. No aseptic loosening's occurred. One individual (OFI-Y) required stoma surgical refashioning due to soft tissue redundancy. At baseline mean ±SD and median (25th to 75th PCTL) Q-TFA PUS and GS were 52±39, 52(7-90) and 40±19, 42(25-50) and improved significantly to 88±18, 90 (90-100) and 71±15, 75 (67-83) at one-year follow-up. The GS Q3 improved over time. CONCLUSION: Titanium osseointegration implants can be safely used within a one-year follow-up period. The performance improved compared to the use of a socket-suspended prosthesis.


Assuntos
Prótese Ancorada no Osso/efeitos adversos , Fêmur/fisiologia , Extremidade Inferior/cirurgia , Osseointegração/efeitos dos fármacos , Qualidade de Vida , Segurança , Titânio/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fêmur/efeitos dos fármacos , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo , Adulto Jovem
2.
Unfallchirurg ; 120(4): 293-299, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28097370

RESUMO

This article reviews the development of multidisciplinary osseointegration treatment in the Netherlands since its start in 2009. People experiencing limitations due to their socket prosthesis after a leg amputation present to the Radboud University Nijmegen Medical Centre for an osseointegration implant or "bone-anchored" prosthesis. In this article we share our experience with the first 100 patients regarding referral pattern, selection criteria, available osseointegration systems, preoperative planning, surgical treatment, the rehabilitation protocol, outcome measurement, revision surgery, and future developments.


Assuntos
Cotos de Amputação , Amputação Cirúrgica/reabilitação , Membros Artificiais , Exoesqueleto Energizado , Osseointegração , Equipe de Assistência ao Paciente/organização & administração , Implantação de Prótese/métodos , Medicina Baseada em Evidências , Humanos , Perna (Membro)/cirurgia , Países Baixos , Cuidados Pré-Operatórios/métodos , Desenho de Prótese , Resultado do Tratamento