1.
Clin Imaging ; 41: 118-124, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27840263

RESUMO

PURPOSE: The purpose was to assess image quality of portal-venous phase dual-energy computed tomography (DECT) for liver lesions. METHODS: We performed 120-kVp-equivalent linear-blended (LB) and monoenergetic reconstructions from 40 to 190 keV by standard (VMI) and advanced virtual monoenergetic (VMI+) methods. Diagnostic performance, and quantitative and qualitative image analyses were assessed and compared. RESULTS: Liver contrast to noise ratio peaked at 40 keV_VMI+, while image quality and reader preference peaked at 50 keV_VMI+. 50 keV_VMI+ scored overall higher diagnostic performance: lesion sensitivity 95.4% vs. 83.3% for both 75 keV_VMI and LB. CONCLUSIONS: DECT improves assessment of hypoenhancing liver lesions on portal venous phase. 50 keV_VMI+ demonstrated the highest image quality and diagnostic performance over VMI and LB.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Veia Porta/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS