Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Agric Food Chem ; 71(37): 13899-13905, 2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37677086

RESUMO

Detecting bovine tuberculosis (bTB) primarily relies on the tuberculin skin test, requiring two separate animal handling events with a period of incubation time (normally 3 days) between them. Here, we present the use of liquid atmospheric pressure (LAP)-MALDI for the identification of bTB infection, employing a three-class prediction model that was obtained by supervised linear discriminant analysis (LDA) and tested with bovine mastitis samples as disease-positive controls. Noninvasive collection of nasal swabs was used to collect samples, which were subsequently subjected to a short (<4 h) sample preparation method. Cross-validation of the three-class LDA model from the processed nasal swabs provided a sensitivity of 75.0% and specificity of 90.1%, with an overall classification accuracy of 85.7%. These values are comparable to those for the skin test, showing that LAP-MALDI MS has the potential to provide an alternative single-visit diagnostic platform that can detect bTB within the same day of sampling.


Assuntos
Tuberculose Bovina , Animais , Feminino , Bovinos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Tuberculose Bovina/diagnóstico , Pressão Atmosférica , Biomarcadores , Análise Discriminante
2.
Clin Chem Lab Med ; 58(6): 930-938, 2020 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-31851611

RESUMO

Background In recent years, mass spectrometry (MS) has been applied to clinical microbial biotyping, exploiting the speed of matrix-assisted laser desorption/ionization (MALDI) in recording microbe-specific MS profiles. More recently, liquid atmospheric pressure (AP) MALDI has been shown to produce extremely stable ion flux from homogenous samples and 'electrospray ionization (ESI)-like' multiply charged ions for larger biomolecules, whilst maintaining the benefits of traditional MALDI including high tolerance to contaminants, low analyte consumption and rapid analysis. These and other advantages of liquid AP-MALDI MS have been explored in this study to investigate its potential in microbial biotyping. Methods Genetically diverse bacterial strains were analyzed using liquid AP-MALDI MS, including clinically relevant species such as Escherichia coli, Staphylococcus aureus and Klebsiella pneumoniae. Bacterial cultures were subjected to a simple and fast extraction protocol using ethanol and formic acid. Extracts were spotted with a liquid support matrix (LSM) and analyzed using a Synapt G2-Si mass spectrometer with an in-house built AP-MALDI source. Results Each species produces a unique lipid profile in the m/z range of 400-1100, allowing species discrimination. Traditional (solid) MALDI MS produced spectra containing a high abundance of matrix-related clusters and an absence of lipid peaks. The MS profiles of the bacterial species tested form distinct clusters using principle component analysis (PCA) with a classification accuracy of 98.63% using a PCA-based prediction model. Conclusions Liquid AP-MALDI MS profiles can be sufficient to distinguish clinically relevant bacterial pathogens and other bacteria, based on their unique lipid profiles. The analysis of the lipid MS profiles is typically excluded from commercial instruments approved for clinical diagnostics.


Assuntos
Pressão Atmosférica , Bactérias/isolamento & purificação , Bactérias/metabolismo , Lipidômica/métodos , Humanos , Limite de Detecção , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...