Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97
Filtrar
1.
Eur Heart J Case Rep ; 6(11): ytac435, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36451807

RESUMO

Background: Due to the increasing prevalence of Kawasaki Disease (KD) in adulthood, the number of women considering pregnancy is growing. There are limited data on the course of pregnancy in KD with coronary artery involvement. Case summary: We report on the pregnancy outcome of a 30-year-old woman with KD who was successfully resuscitated for ventricular tachycardia 3 years before. At that time, bypass surgery and later implantable cardioverter-defibrillator implantation were performed because of thrombotically occluded calcified giant coronary aneurysms. The pregnancy course was initially uncomplicated, however, at 31 weeks of gestation, left-sided breast cancer was diagnosed. Weighing maximum therapeutic efficacy against acceptable foetal and maternal cardiotoxic risk, our multidisciplinary team decided on neoadjuvant chemotherapy. The mother and foetus tolerated the therapy well. However, at 36 weeks of gestation, due to HELLP (haemolysis, elevated liver, low platelets) syndrome, a caesarean section had to be performed. The newborn was healthy with good APGAR (appearance, pulse, grimace, activity, respiration) scores. Three weeks after delivery, chemotherapy was restarted and at Week 4 after the caesarean section, the tumour was no more detectable. Discussion: We discuss data on pregnancy and KD and outline that pregnancy can be considered if the clinical condition is good and left ventricular function is preserved. We also address possible therapeutic approaches and care for breast cancer in pregnancy and coexisting cardiovascular disease. The extraordinary importance of interdisciplinary cooperation between different disciplines in such complex clinical disease conditions is emphasized.

2.
Front Cardiovasc Med ; 9: 928740, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35935663

RESUMO

Background: In most cases of transcatheter valve embolization and migration (TVEM), the embolized valve remains in the aorta after implantation of a second valve into the aortic root. There is little data on potential late complications such as valve thrombosis or aortic wall alterations by embolized valves. Aims: The aim of this study was to analyze the incidence of TVEM in a large cohort of patients undergoing transcatheter aortic valve implantation (TAVI) and to examine embolized valves by computed tomography (CT) late after TAVI. Methods: The patient database of our center was screened for cases of TVEM between July 2009 and July 2021. To identify risk factors, TVEM cases were compared to a cohort of 200 consecutive TAVI cases. Out of 35 surviving TVEM patients, ten patients underwent follow-up by echocardiography and CT. Results: 54 TVEM occurred in 3757 TAVI procedures, 46 cases were managed percutaneously. Horizontal aorta (odds ratio [OR] 7.51, 95% confidence interval [CI] 3.4-16.6, p < 0.001), implantation of a self-expanding valve (OR 4.63, 95% CI 2.2-9.7, p < 0.01) and a left ventricular ejection fraction < 40% (OR 2.94, 95% CI 1.1-7.3, p = 0.016) were identified as risk factors for TVEM. CT scans were performed on average 26.3 months after TAVI (range 2-84 months) and detected hypoattenuated leaflet thickening (HALT) in two patients as well as parts of the stent frame protruding into the aortic wall in three patients. Conclusion: TVEM represents a rare complication of TAVI. Follow up-CT detected no pathological findings requiring intervention.

3.
J Reg Sci ; 62(3): 889-908, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35599965

RESUMO

The health impact of the COVID-19 pandemic across OECD (Organisation for Economic Co-operation and Development) and European regions has been strikingly uneven. In 2020, excess mortality rates in the hardest-hit regions were, on average, 17 percentage points higher than those in the least affected regions of the same country. This paper shows that low health system capacity, followed by population density, air pollution, the share of elderly people, and low institutional quality were associated with higher excess mortality during the first year of the pandemic. Finally, reduced home-to-work mobility, following governments' COVID-19 responses, was associated with lower excess mortality 2 months after implementation of the measures.

4.
Front Cardiovasc Med ; 8: 706628, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34568450

RESUMO

Background: In patients with aortic stenosis, computed tomography (CT) provides important information about cardiovascular anatomy for treatment planning but is limited in determining relevant hemodynamic parameters such as the transvalvular pressure gradient (TPG). Purpose: In the present study, we aimed to validate a reduced-order model method for assessing TPG in aortic stenosis using CT data. Methods: TPGCT was calculated using a reduced-order model requiring the patient-specific peak-systolic aortic flow rate (Q) and the aortic valve area (AVA). AVA was determined by segmentation of the aortic valve leaflets, whereas Q was quantified based on volumetric assessment of the left ventricle. For validation, invasively measured TPGcatheter was calculated from pressure measurements in the left ventricle and the ascending aorta. Altogether, 84 data sets of patients with aortic stenosis were used to compare TPGCT against TPGcatheter. Results: TPGcatheter and TPGCT were 50.6 ± 28.0 and 48.0 ± 26 mmHg, respectively (p = 0.56). A Bland-Altman analysis revealed good agreement between both methods with a mean difference in TPG of 2.6 mmHg and a standard deviation of 19.3 mmHg. Both methods showed good correlation with r = 0.72 (p < 0.001). Conclusions: The presented CT-based method allows assessment of TPG in patients with aortic stenosis, extending the current capabilities of cardiac CT for diagnosis and treatment planning.

5.
Radiol Case Rep ; 16(8): 2112-2118, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34158905

RESUMO

This case report presents the diagnostic workup of liver malignancy incidentally detected in a 72-year-old male patient on routine body computed tomography angiography (CTA) performed for planning transcatheter aortic valve implantation (TAVI). The patient initially presented to an outside hospital with chest discomfort, where routine diagnostic procedures in the emergency room revealed grade III aortic valve stenosis. Routine CTA for TAVI planning in our department then revealed tumor thrombosis of the portal vein suspicious for hepatic malignancy. In contrast-enhanced ultrasound (CEUS) only the left hepatic lobe was inhomogeneously transformed with early arterial contrast enhancement. Magnetic resonance imaging (MRI) confirmed a primary hepatic malignancy involving the left liver. Transcutaneous biopsy with ultrasound guidance established the diagnosis of hepatocellular carcinoma (HCC). Incidental findings may be of prognostic relevance for the patient and in a number of cases, TAVI can be a prerequisite for the appropriate therapy.

6.
Eur Radiol ; 31(3): 1471-1481, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32902743

RESUMO

OBJECTIVES: To test the accuracy of clinical pre-test probability (PTP) for prediction of obstructive coronary artery disease (CAD) in a pan-European setting. METHODS: Patients with suspected CAD and stable chest pain who were clinically referred for invasive coronary angiography (ICA) or computed tomography (CT) were included by clinical sites participating in the pilot study of the European multi-centre DISCHARGE trial. PTP of CAD was determined using the Diamond-Forrester (D+F) prediction model initially introduced in 1979 and the updated D+F model from 2011. Obstructive coronary artery disease (CAD) was defined by one at least 50% diameter coronary stenosis by both CT and ICA. RESULTS: In total, 1440 patients (654 female, 786 male) were included at 25 clinical sites from May 2014 until July 2017. Of these patients, 725 underwent CT, while 715 underwent ICA. Both prediction models overestimated the prevalence of obstructive CAD (31.7%, 456 of 1440 patients, PTP: initial D+F 58.9% (28.1-90.6%), updated D+F 47.3% (34.2-59.9%), both p < 0.001), but overestimation of disease prevalence was higher for the initial D+F (p < 0.001). The discriminative ability was higher for the updated D+F 2011 (AUC of 0.73 95% confidence interval [CI] 0.70-0.76 versus AUC of 0.70 CI 0.67-0.73 for the initial D+F; p < 0.001; odds ratio (or) 1.55 CI 1.29-1.86, net reclassification index 0.11 CI 0.05-0.16, p < 0.001). CONCLUSIONS: Clinical PTP calculation using the initial and updated D+F prediction models relevantly overestimates the actual prevalence of obstructive CAD in patients with stable chest pain clinically referred for ICA and CT suggesting that further refinements to improve clinical decision-making are needed. TRIAL REGISTRATION: https://www.clinicaltrials.gov/ct2/show/NCT02400229 KEY POINTS: • Clinical pre-test probability calculation using the initial and updated D+F model overestimates the prevalence of obstructive CAD identified by ICA and CT. • Overestimation of disease prevalence is higher for the initial D+F compared with the updated D+F. • Diagnostic accuracy of PTP assessment varies strongly between different clinical sites throughout Europe.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/epidemiologia , Europa (Continente) , Feminino , Humanos , Masculino , Alta do Paciente , Projetos Piloto , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco
7.
Rheumatol Int ; 40(6): 893-899, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32240350

RESUMO

OBJECTIVES: X-ray is the fundamental imaging technique in both diagnosis and follow-up of rheumatic diseases. As patients often require sequential X-rays over many years, dose reduction is of great importance. New advanced noise reduction algorithms allow for a dose reduction of up to 50%. The aim of this study was to evaluate whether quality of low-dose images is non-inferior to standard-dose images and, therefore, application of this technique is possible in the context of imaging of rheumatic diseases. METHODS: A total of 298 patients with known or suspected rheumatic disease were enrolled prospectively into this study, separated into three consecutive groups: 80%, 64% and 50% tube charge reduction. All patients received imaging of one hand (laterality randomly assigned) with low-dose technique and imaging of the contralateral hand with standard-dose protocol. Images were evaluated by two independent readers who scored (on a scale of 1-5) the visualization of bony cortex, trabeculae and joint spaces of fingers and wrist separately. Additionally, soft tissue and overall contrast were evaluated on the same scale. RESULTS: Overall image quality (expressed by mean sum score out of 40) of the 50% low-dose images was 31.52 (SD 1.94) vs. 31.66 (SD 1.82) for standard images (p = 0.068). Bony contours as well as trabeculae were equally well visualized in both image sets. Median scores for soft tissue visualization was slightly lower for low dose compared to standard images [4 (IQR 3.5-4) vs. 4 (IQR 3.88-4); p = 0.001]. CONCLUSIONS: Overall image quality of low-dose images was not inferior to standard-dose images. Therefore, the application of low-dose technology based on advanced noise estimation algorithms in the context of imaging of rheumatic diseases is possible.


Assuntos
Doenças Reumáticas , Tomografia Computadorizada por Raios X , Humanos , Algoritmos , Dedos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doenças Reumáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
8.
EuroIntervention ; 15(17): 1506-1513, 2020 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-31929100

RESUMO

AIMS: The aim of our study was to compare the impact of implantation of a balloon-expandable transcatheter valve into the inferior vena cava (CAVI) on exercise capacity with optimal medical therapy (OMT) in patients with severe tricuspid regurgitation (TR) and high surgical risk. METHODS AND RESULTS: Twenty-eight patients were randomised to OMT (n=14) or CAVI (n=14). The primary endpoint was maximal oxygen uptake at the three-month follow-up. Secondary endpoints included six-minute walk test, NYHA class, NT-proBNP levels, right heart function, unscheduled heart failure hospitalisation, and quality of life as assessed by the Minnesota Living with Heart Failure Questionnaire (MLHFQ). Patients underwent follow-up examinations one, three, six, and twelve months after randomisation. Maximal oxygen uptake did not change significantly in either group after three months and there was no difference between the OMT and CAVI groups (-0.1±1.8 ml∙kg-1∙min-1 vs -1.0±1.6 ml∙kg-1∙min-1, p=0.4995). Compared to baseline, CAVI improved NYHA class, dyspnoea, and quality of life after three months. However, there were no statistically significant differences in the secondary endpoints between the groups. Four periprocedural complications occurred after CAVI, resulting in open heart surgery. Four patients in the OMT group and eight patients (including four after conversion to surgery) in the CAVI group died from right heart failure, sepsis or haemorrhage. CONCLUSIONS: CAVI did not result in a superior functional outcome compared to OMT. Due to an unexpectedly high rate of valve dislocations, the study was stopped for safety reasons.


Assuntos
Cateterismo Cardíaco/métodos , Cateterismo Venoso Central/métodos , Insuficiência Cardíaca/complicações , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Tricúspide/cirurgia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/instrumentação , Causas de Morte , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Minnesota/epidemiologia , Desenho de Prótese , Qualidade de Vida , Índice de Gravidade de Doença , Taxa de Sobrevida , Resultado do Tratamento , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/epidemiologia , Veia Cava Inferior/fisiopatologia
10.
Eur Radiol ; 29(4): 1714-1723, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30255246

RESUMO

OBJECTIVE: To analyse extracardiac findings in patients without significant coronary artery disease (CAD) in general and in symptomatic patients in particular. METHODS: We searched the Radiology Information System database for coronary computed tomography angiographies (CTA) performed from 2000-2014 and retrospectively enrolled 3,898 patients without significant CAD (coronary stenosis < 50%) in CTA. In 2,330 symptomatic patients, we analysed the spectrum of extracardiac findings and identified pathologies potentially explaining chest pain. Finally, we investigated variables affecting the number of extracardiac findings detected in CTA. RESULTS: Overall extracardiac findings were found in 1,177 patients (30.2%; 95%CI, 28.8-31.7%). 94 patients (2.4%; 95%CI, 2.0-2.9%) had extracardiac findings with a recommendation for follow-up, sixteen patients (0.4%; 95%CI, 0.3-0.7%) had incidental urgent, and another three patients (0.1%; 95%CI, 0.1-0.2%) had incidental malignant extracardiac findings. 185 of 2,330 symptomatic patients (7.9%; 95%CI, 6.9-9.1%) revealed extracardiac findings potentially explaining chest pain after exclusion of significant CAD. The number of extracardiac findings increased significantly with patient age (p < 0.001) and the cumulative experience of the CT reader (p < 0.001). CONCLUSION: 30.2% of patients undergoing CTA for exclusion of CAD had ECF, and 7.9% of symptomatic patients without significant CAD on their examination had findings that could potentially explain their symptoms. KEY POINTS: • Of patients undergoing CTA, 2.8% have relevant incidental extracardiac findings. • CTA could identify the differential diagnosis of chest pain when excluding significant CAD. • Patient age and reader's professional experience influence the number of detected ECFs.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Idoso , Dor no Peito/diagnóstico por imagem , Dor no Peito/etiologia , Diagnóstico Diferencial , Feminino , Humanos , Achados Incidentais , Masculino , Pessoa de Meia-Idade , Sistemas de Informação em Radiologia , Estudos Retrospectivos
11.
Eur Radiol ; 28(10): 4102-4110, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29713779

RESUMO

OBJECTIVES: To determine the prevalence and significance of extracardiac findings (ECF) in a large set of cardiac magnetic resonance (MR) imaging examinations. METHODS: The institutional review board (IRB) of the Charité approved this retrospective, single-centre study. A total of 4376 cardiac MR imaging reports of 3553 patients (age 37.4 ± 20 years, 60.8 % male) examined from 2000 to 2014 were included. Findings with a recommendation for follow-up were considered "major ECF". To analyse the association of indication, age and gender with ECF, Poisson regression and computed incidence rate ratios (IRR) were evaluated. RESULTS: The overall prevalence of ECF was 34% (95% confidence interval [CI] 32.5-35.6%). Major ECF were present in 3.4% (95% CI 2.9-4.1%) while findings that changed patient management were found in 0.9% (95% CI 0.7-1.3%). In the cases of congenital heart disease, ECF prevalence was higher compared to myocarditis (IRR, 6.0; 95% CI 5.1-7.1%; p < 0.001), while the prevalence of major ECF was lower (IRR, 0.2; 95% CI 0.02-0.51%; p < 0.05). Older patient age was associated with more nonvascular ECF (p < 0.001). Female patients had the same probability of having an ECF as male patients (IRR, 1.04; 95% CI 0.95-1.1%; p = 0.43). CONCLUSION: ECF in cardiac MR imaging are present in about every third patient while relevant ECF that change patient management can be found in about one out of 100 patients. Our data suggest that it is important to involve well-trained radiologists in reading cardiac MR images, which often reveal ECF if congenital heart disease is the clinical indication. KEY POINTS: • Extracardiac findings are present in about every third patient. • Relevant ECF changing patient management are found in one out of 100 findings. • Chance of ECF is high in patients with CHD and vascular indications.


Assuntos
Cardiopatias/diagnóstico por imagem , Achados Incidentais , Imageamento por Ressonância Magnética/métodos , Doenças Torácicas/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Miocardite , Prevalência , Análise de Regressão , Estudos Retrospectivos , Doenças Torácicas/diagnóstico por imagem , Adulto Jovem
12.
Br J Radiol ; 91(1084): 20170678, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29260893

RESUMO

OBJECTIVE: To assess the accuracy of an iterative reconstruction (IR) technique for coronary artery calcium scoring with reduced radiation dose. METHODS: 163 consecutive patients underwent twofold scanning by 320-row detector CT at 120 kVp. A low-dose scan at 25% tube current but with standard scan length (14 cm) was followed by a standard dose scan with routine tube current but reduced scan length (10 cm). Reduced dose images were constructed using filtered back-projection (FBP) and IR (adaptive iterative dose reduction in three dimensions). The standard dose scan reconstructed with FBP served as the gold standard for comparisons. Image noise and Agatston coronary calcium scores were determined and compared between the groups. RESULTS: Compared with FBP at standard dose, noise at reduced dose increased markedly with FBP but remained low with IR. Mean Agatston score with FBP at reduced dose showed a significant increase as compared with FBP at standard dose. No significant difference was observed when applying IR at reduced dose. At reduced dose, 38 (23.3%) patients were reassigned to a different cardiovascular risk category with FBP but only 8 (4.9%) with IR. Out of 47 patients with a zero Agatston score, 15 patients (31.9%) were false-positive with FBP at reduced dose, but no false positives were found with IR. CONCLUSION: IR allows accurate coronary artery calcium scoring with a radiation dose reduced by 75%. Advances in knowledge: The application of adaptive iterative dose reduction in three dimensions allows the maintenance of accurate Agatston scores and risk stratification at significantly reduced tube current, thus reducing the patient's exposure to ionizing radiation.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Calcificação Vascular/diagnóstico por imagem , Idoso , Algoritmos , Feminino , Humanos , Masculino , Doses de Radiação , Medição de Risco
13.
Acta Radiol ; 59(2): 161-169, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28513211

RESUMO

Background Computed tomography (CT) of the left atrium (LA) is performed prior to pulmonary vein isolation (PVI) to improve success of circumferential ablation for atrial fibrillation. The ablation procedure itself exposes patients to substantial radiation doses, therefore radiation dose reduction in pre-ablational imaging is of concern. Purpose To assess and compare diagnostic performance of low-radiation dose preprocedural CT in patients scheduled for PVI using two types of reconstruction algorithms. Material and Methods Forty-six patients (61 ± 10 years) scheduled for PVI were enrolled in this study irrespective of body-mass-index or cardiac rhythm at examination. An electrocardiographically triggered dual-source CT scan was performed. Filtered back projection (FBP) and iterative reconstruction (IR) algorithms were applied. Images were integrated into an electroanatomic mapping (EAM) system. Subjective image quality was scored independently by two readers on a five-point scale for both reconstruction algorithms (1 = excellent to 5 = non-diagnostic). Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and effective radiation dose were calculated. Results Data acquisition and EAM integration were successful in all patients. Median image quality score was 1 for both FBP (quartiles = 1, 1.62; range = 1-3) and IR (quartiles = 1, 1.5; range = 1-3). Mean SNR was 7.61 ± 2.14 for FBP and 9.02 ± 2.69 for IR. Mean CNR was 5.92 ± 1.80 for FBP and 6.95 ± 2.29 for IR. Mean effective radiation dose was 0.3 ± 0.1 mSv. Conclusion At a radiation dose of 0.3 ± 0.1 mSv, high-pitch dual-source CT yields LA images of consistently high quality using both FBP and IR. IR raises SNR and CNR without significantly improving subjective image quality.


Assuntos
Átrios do Coração , Veias Pulmonares/cirurgia , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Fibrilação Atrial/cirurgia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação
14.
Med Sci Monit Basic Res ; 22: 67-9, 2016 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-27357920

RESUMO

BACKGROUND We present the case of a 69-year-old female patient with giant aortic aneurysm who underwent previously multiple cardiac surgeries or interventions. CASE REPORT Ross procedure was performed in 2006 due to aortic valve regurgitation and aneurysm of the ascending aorta. In 2010 the patient was re-admitted for pulmonary valve insufficiency and a transcatheter pulmonary valve was implanted. Recently, the patient presented with an aortic arch aneurysm, maximum diameter 78 mm, which was treated by a hybrid approach, implanting a frozen elephant trunk and a covered stent graft. CONCLUSIONS The current case report demonstrates a suitable hybrid option for an extremely demanding procedure by multiple previous cardiac procedures.


Assuntos
Aneurisma Aórtico/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Idoso , Feminino , Humanos , Desenho de Prótese , Stents , Tomografia Computadorizada por Raios X
15.
Eur J Radiol ; 85(5): 963-71, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27130057

RESUMO

OBJECTIVES: To evaluate a software tool that claims to maintain a constant contrast-to-noise ratio (CNR) in high-pitch dual-source computed tomography coronary angiography (CTCA) by automatically selecting both X-ray tube voltage and current. METHODS: A total of 302 patients (171 males; age 61±12years; body weight 82±17kg, body mass index 27.3±4.6kg/cm(2)) underwent CTCA with a topogram-based, automatic selection of both tube voltage and current using dedicated software with quality reference values of 100kV and 250mAs/rotation (i.e., standard values for an average adult weighing 75kg) and an injected iodine load of 222mg/kg. RESULTS: The average radiation dose was estimated to be 1.02±0.64mSv. All data sets had adequate contrast enhancement. Average CNR in the aortic root, left ventricle, and left and right coronary artery was 15.7±4.5, 8.3±2.9, 16.1±4.3 and 15.3±3.9 respectively. Individual CNR values were independent of patients' body size and radiation dose. However, individual CNR values may vary considerably between subjects as reflected by interquartile ranges of 12.6-18.6, 6.2-9.9, 12.8-18.9 and 12.5-17.9 respectively. Moreover, average CNR values were significantly lower in males than females (15.1±4.1 vs. 16.6±11.7 and 7.9±2.7 vs. 8.9±3.0, 15.5±3.9 vs. 16.9±4.6 and 14.7±3.6 vs. 16.0±4.1 respectively). CONCLUSION: A topogram-based automatic selection of X-ray tube settings in CTCA provides diagnostic image quality independent of patients' body size. Nevertheless, considerable variation of individual CNR values between patients and significant differences of CNR values between males and females occur which questions the reliability of this approach.


Assuntos
Angiografia por Tomografia Computadorizada/normas , Angiografia Coronária/normas , Software/normas , Idoso , Algoritmos , Tamanho Corporal , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Valores de Referência , Reprodutibilidade dos Testes , Raios X
18.
J Comput Assist Tomogr ; 39(5): 649-56, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26125297

RESUMO

OBJECTIVE: The aim of the study was to compare radiation exposure and image quality between dedicated computed tomography (CT) protocols for preoperative total hip arthroplasty (THA) planning. METHODS: Three protocols with automated tube current modulation using 64-slice (n = 177) and 128-slice CT scanners without (n = 129) and with automated tube voltage preselection (n = 84) were compared. RESULTS: All 390 CTs were of sufficient quality for THA planning. Mean DLP was 235.0 mGy*cm (effective dose 2.8 mSv). Lowest radiation exposure (2.5 mSv) was seen with automated voltage preselection and the algorithm's selection was 100 kV (90.5% of patients) and 120 kV. Lowest image noise was seen in the highest dose group (3.1 mSv, 128-slice CT fixed tube voltage). A significant difference in cortical bone radiodensity was seen between 100 kV and 120 kV (P < 0.0001). CONCLUSIONS: Preoperative pelvic CT for THA planning is possible with very low radiation dose and reliable quality. Automated voltage preselection further decreases the effective dose by 18.2%.


Assuntos
Artroplastia de Quadril , Doses de Radiação , Exposição à Radiação/estatística & dados numéricos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade
19.
Pacing Clin Electrophysiol ; 37(10): 1291-6, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24888641

RESUMO

BACKGROUND: Postoperative lead perforation is a life-threatening complication of cardiac pacing. Identification of precipitating factors for this serious complication may help to anticipate a specific risk profile and to minimize the incidence. METHODS: We conducted a retrospective tertiary referral center analysis to clarify clinical, anatomical, and technical characteristics related to pacemaker (PM) and cardioverter/defibrillator lead perforation. We examined the baseline characteristics and the symptoms. In a subgroup, we investigated the myocardial thickness on contrast-enhanced cardiac computed tomography. RESULTS: We enrolled 26 patients. Female gender appears to put patients at slightly increased risk for lead perforation. In a majority active fixation leads were used. Symptoms occurred in 72%. Pericardial effusion and tamponade were present in 38% and 19%, respectively. Sensing was compromised in 65%. A high pacing threshold or exit block occurred in 92%. Myocardial thickness did not differ between patients with or without perforation. In 96%, the perforation was treated by transvenous withdrawal. CONCLUSION: Chest pain, phrenic stimulation, bad sensing, or exit block early after PM implantation must prompt radiological and echocardiographic evaluation. A missing pericardial effusion particularly late after implantation does not rule out a perforation. Especially active fixating leads have a higher risk of perforation. With cardiac surgery in standby transvenous withdrawal is a safe way to treat lead perforation.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Traumatismos Cardíacos/etiologia , Coração/anatomia & histologia , Marca-Passo Artificial/efeitos adversos , Complicações Pós-Operatórias/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Derrame Pericárdico , Estudos Retrospectivos , Fatores de Risco
20.
Eur Radiol ; 24(1): 120-7, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23949727

RESUMO

OBJECTIVES: To assess the effect of lower volumes of contrast medium (CM) on image quality in high-pitch dual-source computed tomography coronary angiography (CTCA). METHODS: One-hundred consecutive patients (body weight 65-85 kg, stable heart rate ≤65 bpm, cardiac index ≥2.5 L/min/m(2)) referred for CTCA were prospectively enrolled. Patients were randomly assigned to one of five groups of different CM volumes (G30, 30 mL; G40, 40 mL; G50, 50 mL; G60, 60 mL; G70, 70 mL; flow rate 5 mL/s each, iodine content 370 mg/mL). Attenuation within the proximal and distal coronary artery segments was analysed. RESULTS: Mean attenuation for men and women ranged from 345.0 and 399.1 HU in G30 to 478.2 and 571.8 HU in G70. Mean attenuation values were higher in groups with higher CM volumes (P < 0.0001) and higher in women than in men (P < 0.0001). The proportions of segments with attenuation of at least 300 HU in G30, G40, G50, G60 and G70 were 89 %, 95 %, 98 %, 98 % and 99 %. CM volume of 30 mL in women and 40 mL in men proved to be sufficient to guarantee attenuation of at least 300 HU. CONCLUSIONS: In selected patients high-pitch dual-source CTCA can be performed with CM volumes of 40 mL in men or 30 mL in women. KEY POINTS: • High-pitch dual-source coronary angiography is feasible with low contrast media volumes. • Traditional injection rules still apply: higher volumes result in higher enhancement. • The patient's gender is a co-factor determining the level of contrast enhancement. • Volumes can be reduced down to 30-40 mL in selected patients.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Tomografia Computadorizada Multidetectores/métodos , Relação Dose-Resposta a Droga , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...