J Laparoendosc Adv Surg Tech A ; 12(1): 61-3, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11905864

RESUMO

BACKGROUND AND PURPOSE: The extent of lateral spread of tissue injury is important in the success of a primary anastomosis. We compared the injury produced by the Laparo-sonic Coagulation Shears and the Ligasure system. MATERIALS AND METHODS: Ureters were harvested from domestic farm pigs and ligated with the Laparo-sonic (N = 13) or Ligasure (N = 9) system. The tissues were then fixed, stained, and examined by two pathologists without knowledge of the type of treatment. RESULTS: The mean length of thermal damage from the Ligasure was 2.11 mm (range 1.0-4.0 mm) whereas it was 1.92 (range 0.5-4.25 mm) from the Laparo-sonic system. The difference is not statistically significant. CONCLUSION: Debridement of as much as 5 mm of each cut end produced by the Laparo-sonic or Ligasure system may be beneficial in reducing stricture and leak.


Assuntos
Eletrocoagulação/efeitos adversos , Eletrocoagulação/métodos , Ligadura/instrumentação , Ureter/lesões , Animais , Suínos , Ureter/cirurgia