Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.080
Filtrar
1.
J Am Coll Cardiol ; 84(3): 276-294, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-38986670

RESUMO

BACKGROUND: Complete revascularization with percutaneous coronary intervention improves outcomes compared with culprit revascularization following myocardial infarction (MI) with multivessel coronary artery disease. An all-cause mortality reduction has never been demonstrated. Debate also remains regarding the optimal timing of complete revascularization (immediate or staged), and method of evaluation of nonculprit lesions (physiology or angiography). OBJECTIVES: This study aims to perform an updated systematic review with frequentist and Bayesian network meta-analyses including the totality of randomized data investigating revascularization strategies in patients presenting with MI and multivessel coronary artery disease. METHODS: The primary comparison tested complete vs culprit revascularization. Timing and methods of achieving complete revascularization were assessed. The prespecified primary outcome was all-cause mortality. Outcomes were expressed as relative risk (RR) (95% CI). RESULTS: Twenty-four eligible trials randomized 16,371 patients (weighted mean follow-up: 26.4 months). Compared with culprit revascularization, complete revascularization reduced all-cause mortality in patients with any MI (RR: 0.85; 95% CI: 0.74-0.99; P = 0.04). Cardiovascular mortality, MI, major adverse cardiac events and repeat revascularization were also significantly reduced. In patients presenting with ST-segment elevation myocardial infarction, the point estimate for all-cause mortality with complete revascularization was RR: 0.91 (95% CI: 0.78-1.05; P = 0.18). Rates of stent thrombosis, major bleeding, and acute kidney injury were similar. Immediate complete revascularization ranked higher than staged complete revascularization for all endpoints. CONCLUSIONS: Complete revascularization following MI reduces all-cause mortality, cardiovascular mortality, MI, major adverse cardiac events, and repeat revascularization. There may be benefits to immediate complete revascularization, but additional head-to-head trials are needed.


Assuntos
Infarto do Miocárdio , Metanálise em Rede , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/métodos , Infarto do Miocárdio/cirurgia , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/terapia
2.
Am J Cardiol ; 225: 171-177, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38897265

RESUMO

Severe tricuspid regurgitation remains largely undertreated given limited treatment options. Transcatheter tricuspid valve interventions have emerged as a promising therapy for these patients, and the TRISCEND II pivotal trial is the first randomized controlled trial to evaluate transcatheter tricuspid valve replacement (TTVR). The TRISCEND II pivotal trial studies the transcatheter EVOQUE (Edwards Lifesciences, Irvine, California) tricuspid valve replacement system using a United States Food and Drug Administration Breakthrough Device Designation-a program intended to provide timely access to medical devices by speeding up development, assessment, and review. The TRISCEND II trial is a prospective, multicenter trial that randomizes patients with symptomatic severe tricuspid regurgitation to treatment with either TTVR in conjunction with optimal medical therapy or optimal medical therapy alone. The trial's novel 2-phase design evaluates 30-day safety and 6-month effectiveness end points for the first 150 patients in the initial phase and a 1-year safety and effectiveness end point for the full cohort of 400 patients in the second phase. The TRISCEND II trial's 2-phase trial design provided an opportunity for early review and led to the first commercial approval of a TTVR system. In conclusion, the design of the TRISCEND II trial will likely inform future transcatheter tricuspid device trials.

3.
JACC Adv ; 3(3): 100839, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38938839

RESUMO

Background: Augmented reality (AR) guidance holds potential to improve transcatheter interventions by enabling visualization of and interaction with patient-specific 3-dimensional virtual content. Positioning of cerebral embolic protection devices (CEP) during transcatheter aortic valve replacement (TAVR) increases patient exposure to radiation and iodinated contrast, and increases procedure time. AR may enhance procedural guidance and facilitate a safer intervention. Objectives: The purpose of this study was to develop and test a novel AR guidance system with a custom user interface that displays virtual, patient-specific 3-dimensional anatomic models, and assess its intraprocedural impact during CEP placement in TAVR. Methods: Patients undergoing CEP during TAVR were prospectively enrolled and assigned to either AR guidance or control groups. Primary endpoints were contrast volume used prior to filter placement, times to filter placement, and fluoroscopy time. Postprocedure questionnaires were administered to assess intraprocedural physician experience with AR guidance. Results: A total of 24 patients presenting for TAVR were enrolled in the study (12 with AR guidance and 12 controls). AR guidance eliminated the need for aortic arch angiograms prior to device placement thus reducing contrast volume (0 mL vs 15 mL, P < 0.0001). There was no significant difference in the time required for filter placement or fluoroscopy time. Postprocedure questionnaires indicated that AR guidance increased confidence in wiring of the aortic arch and facilitated easier device placement. Conclusions: We developed a novel AR guidance system that eliminated the need for additional intraprocedural angiograms prior to device placement without any significant difference in time to intervention and offered a subjective improvement in performance of the intervention.

4.
JACC Adv ; 3(3): 100853, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38938841

RESUMO

Background: Low stroke volume index <35 ml/m2 despite preserved ejection fraction (paradoxical low flow [PLF]) is associated with adverse outcomes in patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). However, whether the risk associated with PLF is similar in both sexes is unknown. Objectives: The purpose of this study was to analyze the risk associated with PLF in severe aortic stenosis for men and women randomized to TAVR or SAVR. Methods: Patients with ejection fraction ≥50% from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were stratified by sex and treatment arm. The impact of PLF on the 2-year occurrence of the composite of death or heart failure hospitalization (primary endpoint) and of all-cause mortality alone (secondary endpoint) was analyzed. Analysis of variance was used to assess baseline differences between groups. Multivariate Cox regression analysis was used to identify predictors of the endpoint. Results: Out of 2,242 patients, PLF was present in 390 men and 239 women (30% vs 26%, P = 0.06). PLF was associated with a higher rate of NYHA functional class III to IV dyspnea (60% vs 54%, P < 0.001) and a higher prevalence of atrial fibrillation (39% vs 24%, P < 0.001). PLF was a significant predictor of the primary endpoint among women undergoing SAVR in multivariate analysis (adjusted HR: 2.25 [95% CI: 1.14-4.43], P = 0.02) but was not associated with a worse outcome in any of the other groups (all P > 0.05). Conclusions: In women with PLF, TAVR may improve outcomes compared to SAVR. PLF appears to have less impact on outcomes in men.

5.
JACC Adv ; 3(5): 100959, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38939639

RESUMO

Background: The prognostic value of cardiac damage staging classification based on the extent of extravalvular damage has been proposed in moderate/severe aortic stenosis (AS). Objectives: The purpose of this study was to assess the association of cardiac damage staging with mortality across the spectrum of patients with AS following aortic surgical or transcatheter aortic valve replacement (AVR). Methods: We conducted a pooled meta-analysis of Kaplan-Meier-derived reconstructed time-to-event data from studies published through February 2023. Results: In total, 16 studies (n = 14,499) met our eligibility criteria and included 12,282 patients with symptomatic severe AS and 2,217 patients with asymptomatic severe/moderate AS. For patients with symptomatic severe AS, all-cause mortality was 24.0%, 27.7%, 38.0%, 56.3%, and 57.3% at 5 years in patients with cardiac damage stage 0, 1, 2, 3, and 4, respectively (stage 0 as reference; HR in stage 1: 1.30 [95% CI: 1.03-1.64]; P = 0.029; stage 2: 1.74 [95% CI: 1.41-2.16]; P < 0.001; stage 3: 2.92 [95% CI: 2.35-3.64]; P < 0.001, and stage 4: 3.51 [95% CI: 2.79-4.41]; P < 0.001). For patients with asymptomatic moderate/severe AS, all-cause mortality was 19.3%, 36.9%, 51.7%, and 67.8% at 8 years in patients with cardiac damage stage 0, 1, 2, and 3 to 4, respectively (HR in stage 1: 1.70 [95% CI: 1.21-2.38]; P = 0.002; stage 2: 2.20 [95% CI: 1.60-3.02]; P < 0.001; and stage 3 to 4: 3.90 [95% CI: 2.79-5.47]; P < 0.001). Conclusions: In patients undergoing AVR across the symptomatic and severity spectrum of AS, cardiac damage staging at baseline has important prognostic implications. This pooled meta-analysis in patients undergoing AVR suggests that staging of baseline cardiac damage could be considered for timing and selection of therapy in patients with moderate or severe AS to determine the need for earlier AVR or adjunctive pharmacotherapy to prevent irreversible cardiac damage and improve the long-term prognosis.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38932577

RESUMO

BACKGROUND: Coronary angiography and percutaneous coronary intervention (PCI) in patients with chronic kidney disease (CKD) is associated with increased risk of contrast induced nephropathy (CIN) and requirement for renal replacement therapy (RRT). OBJECTIVES: We aimed to evaluate our single center experience of ultra-low contrast PCI in patients with CKD and to characterize 1 year outcomes. METHODS: We performed a retrospective analysis of ultra-low contrast PCI at our institution between 2016 and 2022. Patients with CKD3b-5 (eGFR <45 mL/min/1.73m2), not on RRT who underwent ultra-low contrast PCI ( < 30 mL of contrast during PCI) were included. Primary outcomes included change in eGFR post-procedurally, and death, RRT requirement, and major adverse cardiac events (MACE) at 1 year follow-up. RESULTS: One hundred patients were included in the study. The median age was 67 years old and 28% were female. The median baseline eGFR was 21.5 mL/min/1.73m2 (IQR 14.08-32.0 mL/min/1.73m2). A median of 8.0 mL (IQR 0-15 mL) of contrast was used during PCI. Median contrast use to eGFR ratio was 0.37 (IQR 0-0.59). There was no significant difference between pre-and postprocedure eGFR (p = 0.84). At 1 year, 8% of patients died, 11% required RRT and 33% experienced MACE. The average time of RRT initiation was 7 months post-PCI. Forty-four patients were undergoing renal transplant evaluation, of which 17 (39%) received a transplant. CONCLUSIONS: In patients with advanced CKD, ultra-low contrast PCI is feasible and safe with minimal need for peri-procedural RRT. Moreover, ultra-low contrast PCI may allow for preservation of renal function in anticipation of renal transplantation.

7.
JACC Heart Fail ; 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38934964

RESUMO

BACKGROUND: The REDUCE LAP-HF II (Reduce Elevated Left Atrial Pressure in Patients With Heart Failure II) trial found that, compared with a sham procedure, the Corvia Atrial Shunt did not improve outcomes in heart failure with preserved or mildly reduced ejection fraction. However, after 12-month follow-up, "responders" (peak-exercise pulmonary vascular resistance <1.74 WU and absence of a cardiac rhythm management device) were identified. OBJECTIVES: This study sought to determine: 1) the overall efficacy and safety of the atrial shunt vs sham control after 2 years of follow-up; and 2) whether the benefits of atrial shunting are sustained in responders during longer-term follow-up or are offset by adverse effects of the shunt. METHODS: The study analyzed 2-year outcomes in the overall REDUCE LAP-HF II trial, as well as in responder and nonresponder subgroups. The primary endpoint was a hierarchical composite of cardiovascular death or nonfatal ischemic/embolic stroke, total heart failure events, and change in health status. RESULTS: In 621 randomized patients, there was no difference between the shunt (n = 309) and sham (n = 312) groups in the primary endpoint (win ratio: 1.01 [95% CI: 0.82-1.24]) or its individual components at 2 years. Shunt patency at 24 months was 98% in shunt-treated patients. Cardiovascular mortality and nonfatal ischemic stroke were not different between the groups; however, major adverse cardiac events were more common in those patients assigned to the shunt compared with sham (6.9% vs 2.7%; P = 0.018). More patients randomized to the shunt had an increase in right ventricular volume of ≥30% compared with the sham control (39% vs 28%, respectively; P < 0.001), but right ventricular dysfunction was uncommon and not different between the treatment groups. In responders (n = 313), the shunt was superior to sham (win ratio: 1.36 [95% CI: 1.02-1.83]; P = 0.037, with 51% fewer HF events [incidence rate ratio: 0.49 [95% CI: 0.25-0.95]; P = 0.034]). In nonresponders (n = 265), atrial shunting was inferior to sham (win ratio: 0.73 [95% CI: 0.54-0.98]). CONCLUSIONS: At 2 years of follow-up in REDUCE LAP-HF II, there was no difference in efficacy between the atrial shunt and sham groups in the overall trial group. The potential clinical benefit identified in the responder group after 1 and 2 years of follow-up is currently being evaluated in the RESPONDER-HF (Re-Evaluation of the Corvia Atrial Shunt Device in a Precision Medicine Trial to Determine Efficacy in Mildly Reduced or Preserved Ejection Fraction Heart Failure) trial. (Reduce Elevated Left Atrial Pressure in Patients With Heart Failure II [REDUCE LAP-HF II]; NCT03088033).

8.
Front Immunol ; 15: 1258369, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38933266

RESUMO

Autoantigen-specific immunotherapy using peptides offers a more targeted approach to treat autoimmune diseases, but clinical implementation has been challenging. We previously showed that multivalent delivery of peptides as soluble antigen arrays (SAgAs) efficiently protects against spontaneous autoimmune diabetes in the non-obese diabetic (NOD) mouse model. Here, we compared the efficacy, safety, and mechanisms of action of SAgAs versus free peptides. SAgAs, but not their corresponding free peptides at equivalent doses, efficiently prevented the development of diabetes. SAgAs increased the frequency of regulatory T cells among peptide-specific T cells or induce their anergy/exhaustion or deletion, depending on the type of SAgA used (hydrolysable (hSAgA) and non-hydrolysable 'click' SAgA (cSAgA)) and duration of treatment, whereas their corresponding free peptides induced a more effector phenotype following delayed clonal expansion. Over time, the peptides induced an IgE-independent anaphylactic reaction, the incidence of which was significantly delayed when peptides were in SAgA form rather than in free form. Moreover, the N-terminal modification of peptides with aminooxy or alkyne linkers, which was needed for grafting onto hyaluronic acid to make hSAgA or cSAgA variants, respectively, influenced their stimulatory potency and safety, with alkyne-functionalized peptides being more potent and less anaphylactogenic than aminooxy-functionalized peptides. Immunologic anaphylaxis occurred in NOD mice in a dose-dependent manner but not in C57BL/6 or BALB/c mice; however, its incidence did not correlate with the level of anti-peptide antibodies. We provide evidence that SAgAs significantly improve the efficacy of peptides to induce tolerance and prevent autoimmune diabetes while at the same time reducing their anaphylactogenic potential.


Assuntos
Diabetes Mellitus Tipo 1 , Tolerância Imunológica , Camundongos Endogâmicos NOD , Peptídeos , Animais , Camundongos , Diabetes Mellitus Tipo 1/imunologia , Peptídeos/imunologia , Peptídeos/administração & dosagem , Feminino , Autoantígenos/imunologia , Linfócitos T Reguladores/imunologia , Imunoterapia/métodos , Anafilaxia/prevenção & controle , Anafilaxia/imunologia , Dessensibilização Imunológica/métodos , Dessensibilização Imunológica/efeitos adversos
9.
Open Heart ; 11(1)2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38890129

RESUMO

BACKGROUND: For high bleeding-risk patients (HBR) undergoing percutaneous coronary intervention (PCI), the LEADERS FREE (LF) and LEADERS FREE II (LF II) trials established the safety and efficacy of a stainless steel polymer-free biolimus-coated stent (SS-BCS) with 30 days of dual antiplatelet treatment (DAPT). The LEADERS FREE III (LF III) trial investigated clinical outcomes after PCI with the next-generation cobalt-chromium thin-strut polymer-free biolimus-coated stent (CoCr-BCS) in HBR patients. AIMS: To report the final 3-year results of the LF III trial and compare them to LF II. METHODS: LF III was a prospective, multicentre, open-label single-arm study to evaluate the safety and efficacy of the CoCr-BCS stent. The primary safety endpoint was the composite of cardiac death (CD), myocardial infarction(MI) or definite/probable stent thrombosis (ST). The primary efficacy endpoint was clinically driven target lesion revascularisation (cd-TLR). We performed a propensity-matched comparison to the 3-year outcomes of LF II. RESULTS: After 3 years, CD/MI/ST had occurred in 57 patients (15%, 95% CI 11.8% to 19%) and cd-TLR in 23 (6.2%, 95% CI 4.1% to 9.2%) patients. In a propensity-matched comparison of patients treated with the CoCr-BCS versus the SS-BCS, there were similar rates of CD (6.6% vs 7.8%, p=0.50), MI (7.1% vs 8.3%, p=0.47) and definite/probable ST (1.1% vs 2%, HR 0.56, 95% CI 0.16 to 1.93, p=0.35). The rates of cd-TLR were 5.3% with CoCr-BCS versus 9.8% with SS-BCS (HR 0.54, 95% CI 0.31 to 0.96, p=0.03). CONCLUSION: LF III confirms the long-term safety and efficacy of the CoCr-BCS in HBR patients treated with 1 month of DAPT. TRIAL REGISTRATION NUMBER: NCT02843633, NCT03118895.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Desenho de Prótese , Sirolimo , Humanos , Masculino , Estudos Prospectivos , Feminino , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/efeitos adversos , Sirolimo/análogos & derivados , Sirolimo/farmacologia , Sirolimo/administração & dosagem , Resultado do Tratamento , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico , Idoso , Fatores de Tempo , Pessoa de Meia-Idade , Seguimentos , Inibidores da Agregação Plaquetária/uso terapêutico , Fatores de Risco
10.
Circulation ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38881496

RESUMO

BACKGROUND: Artificial intelligence, particularly deep learning (DL), has immense potential to improve the interpretation of transthoracic echocardiography (TTE). Mitral regurgitation (MR) is the most common valvular heart disease and presents unique challenges for DL, including the integration of multiple video-level assessments into a final study-level classification. METHODS: A novel DL system was developed to intake complete TTEs, identify color MR Doppler videos, and determine MR severity on a 4-step ordinal scale (none/trace, mild, moderate, and severe) using the reading cardiologist as a reference standard. This DL system was tested in internal and external test sets with performance assessed by agreement with the reading cardiologist, weighted κ, and area under the receiver-operating characteristic curve for binary classification of both moderate or greater and severe MR. In addition to the primary 4-step model, a 6-step MR assessment model was studied with the addition of the intermediate MR classes of mild-moderate and moderate-severe with performance assessed by both exact agreement and ±1 step agreement with the clinical MR interpretation. RESULTS: A total of 61 689 TTEs were split into train (n=43 811), validation (n=8891), and internal test (n=8987) sets with an additional external test set of 8208 TTEs. The model had high performance in MR classification in internal (exact accuracy, 82%; κ=0.84; area under the receiver-operating characteristic curve, 0.98 for moderate/severe MR) and external test sets (exact accuracy, 79%; κ=0.80; area under the receiver-operating characteristic curve, 0.98 for moderate or greater MR). Most (63% internal and 66% external) misclassification disagreements were between none/trace and mild MR. MR classification accuracy was slightly higher using multiple TTE views (accuracy, 82%) than with only apical 4-chamber views (accuracy, 80%). In subset analyses, the model was accurate in the classification of both primary and secondary MR with slightly lower performance in cases of eccentric MR. In the analysis of the 6-step classification system, the exact accuracy was 80% and 76% with a ±1 step agreement of 99% and 98% in the internal and external test set, respectively. CONCLUSIONS: This end-to-end DL system can intake entire echocardiogram studies to accurately classify MR severity and may be useful in helping clinicians refine MR assessments.

11.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38866455

RESUMO

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Estimulação Cardíaca Artificial , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Fatores de Risco , Idoso , Fatores de Tempo , Idoso de 80 Anos ou mais , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Medição de Risco , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Estados Unidos/epidemiologia
12.
Arch. cardiol. Méx ; 94(2): 219-239, Apr.-Jun. 2024. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1556919

RESUMO

resumen está disponible en el texto completo


Abstract This consensus of nomenclature and classification for congenital bicuspid aortic valve and its aortopathy is evidence-based and intended for universal use by physicians (both pediatricians and adults), echocardiographers, advanced cardiovascular imaging specialists, interventional cardiologists, cardiovascular surgeons, pathologists, geneticists, and researchers spanning these areas of clinical and basic research. In addition, as long as new key and reference research is available, this international consensus may be subject to change based on evidence-based data1.

13.
JAMA Cardiol ; 9(7): 631-639, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38776106

RESUMO

Importance: The use of valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) has been rapidly expanding as an alternative treatment to redo surgical aortic valve replacement (SAVR) for failed bioprosthetic valves despite limited long-term data. Objective: To assess mortality and morbidity in patients undergoing intervention for failed bioprosthetic SAVR. Design, Setting, and Participants: This was a retrospective population-based cohort analysis conducted between January 1, 2015, and December 31, 2020, with a median (IQR) follow-up time of 2.3 (1.1-4.0) years. A total of 1771 patients with a history of bioprosthetic SAVR who underwent ViV-TAVR or redo SAVR in California, New York, and New Jersey were included. Data were obtained from the California Department of Health Care Access and Information, the New York Statewide Planning and Research Cooperative System, and the New Jersey Discharge Data Collection System. Exclusion criteria included undergoing TAVR or redo SAVR within 5 years from initial SAVR, as well as infective endocarditis, concomitant surgical procedures, and out-of-state residency. Propensity matching yielded 375 patient pairs. Data were analyzed from January to December 2023. Interventions: ViV-TAVR vs redo SAVR. Main Outcomes and Measurements: The primary outcome was all-cause mortality. Secondary outcomes were stroke, heart failure hospitalization, reoperation, major bleeding, acute kidney failure, new pacemaker insertion, and infective endocarditis. Results: From 2015 through 2020, the proportion of patients undergoing ViV-TAVR vs redo SAVR increased from 159 of 451 (35.3%) to 498 or 797 (62.5%). Of 1771 participants, 653 (36.9%) were female, and the mean (SD) age was 74.4 (11.3) years. Periprocedural mortality and stroke rates were similar between propensity-matched groups. The ViV-TAVR group had lower periprocedural rates of major bleeding (2.4% vs 5.1%; P = .05), acute kidney failure (1.3% vs 7.2%; P < .001), and new pacemaker implantations (3.5% vs 10.9%; P < .001). The 5-year all-cause mortality rate was 23.4% (95% CI, 15.7-34.1) in the ViV-TAVR group and 13.3% (95% CI, 9.2-18.9) in the redo SAVR group. In a landmark analysis, no difference in mortality was observed up to 2 years (hazard ratio, 1.03; 95% CI, 0.59-1.78), but after 2 years, ViV-TAVR was associated with higher mortality (hazard ratio, 2.97; 95% CI, 1.18-7.47) as well as with a higher incidence of heart failure hospitalization (hazard ratio, 3.81; 95% CI, 1.57-9.22). There were no differences in 5-year incidence of stroke, reoperation, major bleeding, or infective endocarditis. Conclusions and Relevance: Compared with redo SAVR, ViV-TAVR was associated with a lower incidence of periprocedural complications and a similar incidence of all-cause mortality through 2 years' follow-up. However, ViV-TAVR was associated with higher rates of late mortality and heart failure hospitalization. These findings may be influenced by residual confounding and require adjudication in a randomized clinical trial.


Assuntos
Bioprótese , Reoperação , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Idoso , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Reoperação/estatística & dados numéricos , Idoso de 80 Anos ou mais , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Falha de Prótese , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos
14.
J Am Coll Cardiol ; 83(20): 2002-2014, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38749619

RESUMO

Orthotopic transcatheter tricuspid valve replacement (TTVR) devices have been shown to be highly effective in reducing tricuspid regurgitation (TR), and interest in this therapy is growing with the recent commercial approval of the first orthotopic TTVR. Recent TTVR studies report preexisting cardiac implantable electronic device (CIED) transvalvular leads in ∼35% of patients, with entrapment during valve implantation. Concerns have been raised regarding the safety of entrapping leads and counterbalanced against the risks of transvenous lead extraction (TLE) when indicated. This Heart Valve Collaboratory consensus document attempts to define the patient population with CIED lead-associated or lead-induced TR, describe the risks of lead entrapment during TTVR, delineate the risks and benefits of TLE in this setting, and develop a management algorithm for patients considered for TTVR. An electrophysiologist experienced in CIED management should be part of the multidisciplinary heart team and involved in shared decision making.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Índice de Gravidade de Doença
15.
Artigo em Inglês | MEDLINE | ID: mdl-38693866

RESUMO

AIMS: Evaluation of left and right ventricular longitudinal systolic function may enhance risk stratification following aortic valve replacement (AVR). The study objective was to evaluate the changes in left and right ventricular longitudinal systolic function and RV-pulmonary artery (RV-PA) coupling from baseline to 30-days and 1-year after aortic valve replacement (AVR). METHODS AND RESULTS: LV longitudinal strain (LS), tricuspid annulus plane systolic excursion (TAPSE), and RV-PA coupling were evaluated in patients from the PARTNER-2A surgical AVR (SAVR) arm (n=985) and from the PARTNER-2 SAPIEN-3 registry (n=719). TAPSE and RV-PA coupling decreased significantly following SAVR, but remained stable following TAVR. Lower LV LS, TAPSE, or RV-PA coupling at baseline were associated with increased risk of the composite of death, hospitalization, and stroke at 5-years (Adjusted-HRs for LV LS<15%: 1.24 95%CI 1.05-1.45, p=0.001; TAPSE<14mm: 1.44 95%CI 1.21-1.73, p<0.001; RV/PA coupling<0.55mm/mmHg: 1.32 95% CI 1.07-1.63, p=0.011). Reduced TAPSE at baseline was the most powerful predictor of the composite endpoint at 5-years. Patients with LV ejection fraction <50% at baseline had increased risk of the primary endpoint with SAVR (HR: 1.34, 95%CI 1.08-1.68, p=0.009) but not with TAVR (HR: 1.12, 95%CI 0.88-1.42). Lower RV-PA coupling at 30-days showed the strongest association with cardiac mortality. CONCLUSION: SAVR but not TAVR was associated with a marked deterioration in RV longitudinal systolic function and RV-PA coupling. Lower TAPSE and RV-PA coupling at 30-days were associated with inferior clinical outcomes at 5-years. In patients with LVEF<50%, TAVR was associated with superior 5-year outcomes.

16.
Eur Heart J ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747561

RESUMO

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

17.
EuroIntervention ; 20(9): 536-550, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726720

RESUMO

The identification and management of patients at high bleeding risk (HBR) undergoing transcatheter aortic valve implantation (TAVI) are of major importance, but the lack of standardised definitions is challenging for trial design, data interpretation, and clinical decision-making. The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) is a collaboration among leading research organisations, regulatory authorities, and physician-scientists from Europe, the USA, and Asia, with a major focus on TAVI-related bleeding. VARC-HBR is an initiative of the CERC (Cardiovascular European Research Center), aiming to develop a consensus definition of TAVI patients at HBR, based on a systematic review of the available evidence, to provide consistency for future clinical trials, clinical decision-making, and regulatory review. This document represents the first pragmatic approach to a consistent definition of HBR evaluating the safety and effectiveness of procedures, devices and drug regimens for patients undergoing TAVI..


Assuntos
Consenso , Hemorragia , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Hemorragia/etiologia , Medição de Risco , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia
18.
JACC Cardiovasc Interv ; 17(12): 1440-1451, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38639690

RESUMO

BACKGROUND: Thirty-day outcomes with the investigational Intrepid transapical (TA) transcatheter mitral valve replacement (TMVR) system have previously demonstrated good technical success, but longer-term outcomes in larger cohorts need to be evaluated. OBJECTIVES: The authors sought to evaluate the 2-year safety and performance of the Intrepid TA-TMVR system in patients with symptomatic, ≥moderate-severe mitral regurgitation (MR) and high surgical risk. METHODS: Patient eligibility was determined by local heart teams and approved by a central screening committee. Clinical events were adjudicated by an independent clinical events committee. Echocardiography was evaluated by an independent core laboratory. RESULTS: The cohort included 252 patients that were enrolled at 58 international sites before February 2021 as part of the global Pilot Study (n = 95) or APOLLO trial (primary cohort noneligible + TA roll-ins, n = 157). Mean age was 74.2 years, mean STS-PROM was 6.3%, 60.3% were male, and 80.6% were in NYHA functional class III/IV. Most presented with secondary MR (70.1%), and nearly all had ≥moderate-severe MR (98.4%). All-cause mortality was 13.1% (30-day), 27.3% (1-year), and 36.2% (2-year). The 30-day ≥major bleeding event rate was 22.3%. Heart failure rehospitalization was 9.6% (30-day) and 36.2% (2-year). At 2 years, >50% of patients were alive with improvement in NYHA functional class (82.1%, class I/II), and all patients with available echocardiograms had ≤mild MR. CONCLUSIONS: This analysis represents the largest reported TA-TMVR experience with the longest follow-up in high-risk ≥moderate-severe MR patients. Early mortality and heart failure rehospitalizations were significant, exacerbated by early TA-related bleeding events; however, meaningful improvements in clinical outcomes and marked reductions in MR severity were observed through 2 years.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Valva Mitral , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/mortalidade , Feminino , Masculino , Idoso , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Fatores de Tempo , Idoso de 80 Anos ou mais , Fatores de Risco , Desenho de Prótese , Valor Preditivo dos Testes , Complicações Pós-Operatórias/etiologia , Pessoa de Meia-Idade , Hemodinâmica , Readmissão do Paciente , Ecocardiografia
19.
JAMA Cardiol ; 9(6): 507-522, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38630494

RESUMO

Importance: Although the results of A Study to Evaluate the Corvia Medical Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure (REDUCE LAP-HF II) trial were neutral overall, atrial shunt therapy demonstrated potential efficacy in responders (no latent pulmonary vascular disease and no cardiac rhythm management device). Post hoc analyses were conducted to evaluate the effect of shunt vs sham stratified by responder status. Objective: To evaluate the effect of atrial shunt vs sham control on cardiac structure/function in the overall study and stratified by responder status. Design, Setting, and Participants: This was a sham-controlled randomized clinical trial of an atrial shunt device in heart failure with preserved ejection fraction (HFpEF)/HF with mildly reduced EF (HFmrEF). Trial participants with evaluable echocardiography scans were recruited from 89 international medical centers. Data were analyzed from April 2023 to January 2024. Interventions: Atrial shunt device or sham control. Main Outcome Measures: Changes in echocardiographic measures from baseline to 1, 6, 12, and 24 months after index procedure. Results: The modified intention-to-treat analysis of the REDUCE LAP-HF II trial included 621 randomized patients (median [IQR] age, 72.0 [66.0-77.0] years; 382 female [61.5%]; shunt arm, 309 [49.8%]; sham control arm, 312 [50.2%]). Through 24 months, 212 of 217 patients (98%) in the shunt arm with evaluable echocardiograms had patent shunts. In the overall trial population, the shunt reduced left ventricular (LV) end-diastolic volume (mean difference, -5.65 mL; P <.001), left atrial (LA) minimal volume (mean difference, -2.8 mL; P =.01), and improved LV systolic tissue Doppler velocity (mean difference, 0.69 cm/s; P <.001) and LA emptying fraction (mean difference, 1.88 percentage units; P =.02) compared with sham. Shunt treatment also increased right ventricular (RV; mean difference, 9.58 mL; P <.001) and right atrial (RA; mean difference, 9.71 mL; P <.001) volumes but had no effect on RV systolic function, pulmonary artery pressure, or RA pressure compared with sham. In the shunt arm, responders had smaller increases in RV end-diastolic volume (mean difference, 5.71 mL vs 15.18 mL; interaction P =.01), RV end-systolic volume (mean difference, 1.58 mL vs 7.89 mL; interaction P =.002), and RV/LV ratio (mean difference, 0.07 vs 0.20; interaction P <.001) and larger increases in transmitral A wave velocity (mean difference, 5.08 cm/s vs -1.97 cm/s; interaction P =.02) compared with nonresponders randomized to the shunt, suggesting greater ability to accommodate shunted blood through the pulmonary circulation enabling LA unloading. Conclusions and Relevance: In this post hoc analysis of the REDUCE LAP-HF II trial, over 2 years of follow-up, atrial shunting led to reverse remodeling of left-sided chambers and increases in volume of right-sided chambers consistent with the shunt flow but no change in RV systolic function compared with sham. Changes in cardiac structure/function were more favorable in responders compared with nonresponders treated with the shunt, supporting the previously identified responder group hypothesis and mechanism, although further evaluation with longer follow-up is needed. Trial Registration: ClinicalTrials.gov Identifier: NCT03088033.


Assuntos
Insuficiência Cardíaca , Volume Sistólico , Humanos , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Masculino , Volume Sistólico/fisiologia , Idoso , Pessoa de Meia-Idade , Ecocardiografia , Átrios do Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Resultado do Tratamento
20.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599688

RESUMO

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Estudos Multicêntricos como Assunto , Sistema de Registros
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...