Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pediatr Res ; 86(2): 216-220, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30696987

RESUMO

BACKGROUND: This study aimed to determine the accuracy of a point-of-care Bilistick method for measuring total serum bilirubin (TSB) and its turn-around-time (TAT) against hospital laboratory methods. METHODS: This prospective study was carried out on 561 term-gestation jaundiced neonates in two Malaysian hospitals. Venous blood sample was collected from each neonate for contemporary measurement of TSB by hospital laboratories and Bilistick. TAT was the time interval between specimen collection and TSB result reported by each method. RESULTS: The mean laboratory-measured TSB was 194.85 (±2.844) µmol/L and Bilistick TSB was 169.37 (±2.706) µmol/L. Pearson's correlation coefficient was: r = 0.901 (p < 0.001). The mean difference of [laboratory TSB- Bilistick TBS] was 26.48 (±29.41) µmol/L. The Bland-Altman plots show that the 95% limits of agreement (-31.1577, 84.11772) contain 94.7% (=531/561) of the difference in TSB readings. Bilistick has a 99% accuracy and 100% sensitivity to predict laboratory TSB levels of ≥80 µmol/L and ≥360 µmol/L at lower Bilistick TSB levels of ≥55 and ≥315 µmol/L, respectively. TAT of Bilistick TSB (2.0 min) was significantly shorter than TAT (105 min) of laboratory TSB (p < 0.001). CONCLUSIONS: Bilistick has shorter TAT. The accuracy and sensitivity of Bilistick TSB for predicting laboratory TSB is high at lower cutoff levels.


Assuntos
Bilirrubina/sangue , Icterícia Neonatal/sangue , Icterícia Neonatal/diagnóstico , Triagem Neonatal/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito/normas , Feminino , Idade Gestacional , Humanos , Hiperbilirrubinemia Neonatal , Recém-Nascido , Modelos Lineares , Malásia , Masculino , Triagem Neonatal/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
2.
Singapore Med J ; 59(4): 177-182, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29748692

RESUMO

A 20-year-old National Serviceman presented with left knee pain and swelling after training for his physical fitness test. Lateral knee radiography and magnetic resonance (MR) imaging showed patellar tendon-lateral femoral condyle friction syndrome (PT-LFCFS), on a background of patella alta and patellar malalignment. The patient was treated non-operatively with a course of physiotherapy and given advice on rest and activity modification. PT-LFCFS is a less well-recognised but important cause of anterior knee pain and represents an entity in a spectrum of disorders related to patellofemoral instability. We herein discuss the MR imaging findings specific to and associated with this condition, as well as briefly describing treatment options. In addition, we showcase a range of commonly encountered abnormalities that affect the infrapatellar fat pad and briefly discuss their specific MR imaging findings.


Assuntos
Fêmur/diagnóstico por imagem , Traumatismos do Joelho/terapia , Patela/diagnóstico por imagem , Modalidades de Fisioterapia , Adulto , Artralgia/diagnóstico por imagem , Feminino , Humanos , Joelho/diagnóstico por imagem , Traumatismos do Joelho/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Dor/diagnóstico por imagem , Ligamento Patelar/diagnóstico por imagem , Radiografia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...