1.
Sportverletz Sportschaden ; 38(2): 89-99, 2024 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-38781978

RESUMO

Ultrasound (US) has numerous applications in sports traumatology. The technical progress of mobile US devices has led to increasing use of ultrasound as a primary diagnostic tool. New applications such as elastography and 3 D vascularization are used for special indications.The purpose of this review is to present the current status of ultrasound in the diagnosis of sports injuries and sport traumatology including established applications and new technical advances. US is presented both in its comparison to other imaging modalities and as a sole diagnostic tool.US can be used for initial diagnosis to improve the clinical examination and for intensive shortterm follow-up imaging. The main areas of application are currently the diagnosis of acute muscle and tendon injuries as well as overuse injuries. In particular, the exclusion of structural muscle injuries can be adequately ensured with US in the majority of anatomical regions. The recently published guideline on fracture ultrasound has strengthened the clinical evidence in this area, especially in comparison to conventional radiography and in the development of algorithms and standards. The increasing use of mobile ultrasound equipment with adequate image quality makes US a location-independent modality that can also be used at training sites or during road games.


Assuntos
Traumatismos em Atletas , Medicina Esportiva , Ultrassonografia , Humanos , Traumatismos em Atletas/diagnóstico por imagem , Traumatismos dos Tendões/diagnóstico por imagem , Traumatologia , Transtornos Traumáticos Cumulativos/diagnóstico por imagem
2.
Diagnostics (Basel) ; 14(2)2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38248038

RESUMO

Some authors consider the risk of bleeding an absolute contraindication to percutaneous image-guided splenic puncture. While splenic punctures are mainly performed at specialized centers, no technique for the closure of the puncture tract has been broadly established. The aim of this study was to investigate the effectiveness and safety of a percutaneous image-guided biopsy of the spleen using fibrin glue to plug the tract. A total of 27 requests for splenic image-guided interventions were identified between 2010 and 2021 and considered for inclusion in our retrospective single-center study. Seven patients needed to be excluded, which left twenty patients who underwent a percutaneous computed tomography (CT) fluoroscopy-guided biopsy of a splenic lesion during this period. In all patients, a 17G coaxial needle with an 18G core biopsy needle was used. Diagnostic adequacy and accuracy were evaluated, and complications were classified using the CIRSE classification system for adverse events. Diagnostic adequacy was 100% (20/20), and a median of four samples were collected. Diagnostic accuracy was 80% (16/20). The four off-target samples included one inconclusive finding and three samples of regular spleen tissue. The overall complication rate was 5% (1/20). No mild (grade 1-2) or moderate (grade 3-4) complications occurred. One severe (grade 5-6) complication occurred. Although controversial and potentially high-risk, diagnostic percutaneous biopsies of the spleen appear to be relatively safe with the use of fibrin glue to seal the tract.

3.
Ultraschall Med ; 45(1): 47-53, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37072033

RESUMO

BACKGROUND: To investigate the inter- and intraobserver variability in comparison to an expert gold standard of the new and modified renal cyst Bosniak classification proposed for contrast-enhanced ultrasound findings (CEUS) by the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) in 2020. MATERIALS AND METHODS: 84 CEUS examinations for the evaluation of renal cysts were evaluated retrospectively by six readers with different levels of ultrasound expertise using the modified Bosniak classification proposed for CEUS. All cases were anonymized, and each case was rated twice in randomized order. The consensus reading of two experts served as the gold standard, to which all other readers were compared. Statistical analysis was performed using Cohen's weighted kappa tests, where appropriate. RESULTS: Intraobserver variability showed substantial to almost perfect agreement (lowest kappa κ=0.74; highest kappa κ=0.94), with expert level observers achieving the best results. Comparison to the gold standard was almost perfect for experts (highest kappa κ=0.95) and lower for beginner and intermediate level readers still achieving mostly substantial agreement (lowest kappa κ=0.59). Confidence of rating was highest for Bosniak classes I and IV and lowest for classes IIF and III. CONCLUSION: Categorization of cystic renal lesions based on the Bosniak classification proposed by the EFSUMB in 2020 showed very good reproducibility. While even less experienced observers achieved mostly substantial agreement, training remains a major factor for better diagnostic performance.


Assuntos
Cistos , Doenças Renais Císticas , Neoplasias Renais , Humanos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Meios de Contraste , Doenças Renais Císticas/diagnóstico por imagem , Ultrassonografia/métodos
4.
Diagnostics (Basel) ; 13(23)2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-38066738

RESUMO

Relationship between stiffness of genioglossi (GG) and geniohyoidei (GH) muscles under electric hypoglossal nerve stimulation therapy (HNS) in relation to success of therapy was investigated with additional special focus on tongue movement. PATIENTS AND METHODS: Clinical and sleep laboratory parameters of a cohort of 18 patients with known shear wave velocity (SWV) data of the ipsilateral and contralateral musculi GG and GH (sGG, sGH and nGG, nGH) before and under HNS therapy were analyzed. The SWV was already determined using the ultrasonic shear wave elastography (US-SWE) technique. RESULTS: Median Epworth Sleepiness Scale (ESS) was 8 (IQR 12), median baseline Apnoe-Hypopnoe Index (AHI) 31.65 (IQR 25.1), median AHI under HNS therapy 16.3 (IQR 20.03). Therapy success: 9/18 patients (AHI during therapy < 15/h). There was no significant difference in SWV (sGG, sGH, nGG and nGH) between therapy responders and non-responders during therapy. Also, no difference could be seen with respect to the difference and increase in SWV values without and with stimulation. Examination of SWV values (sGG, sGH, nGG, nGH during stimulation, difference of SWV values stimulation - no stimulation, increase factor of SWV) revealed a significant negative correlation between the AHI under therapy and the measured SWV of the musculus GH of the contralateral side during stimulation (-0.622, p = 0.006). Patients with bilateral protrusion of the tongue differed regarding to therapy success in increase in SWV in sGG (p = 0.032). Tongue protrusion to contralateral: A significant difference between patients with AHI during therapy < 15/h in SWV values at sGG without stimulation (p = 0.021) was seen, with also a correlation to the current AHI under therapy (p = 0.047) and the change factor of the AHI (p = 0.015). CONCLUSION: Stiffness of the target muscle does not appear to be an isolated measure of the success of HNS therapy. This observation may have implications for future decision-making processes in the process of titrating electrical therapy parameters. But the technique of US-SWE may be useful for future research of the neurophysiology of the tongue and OSA phenotyping.

5.
Rofo ; 2023 Nov 09.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-37944936

RESUMO

BACKGROUND: Ultrasound (US) has numerous applications in sports traumatology. The technical progress of mobile US devices has led to increasing use of ultrasound as a primary diagnostic tool. New applications such as elastography and 3 D vascularization are used for special indications. METHOD: The purpose of this review is to present the current status of ultrasound in the diagnosis of sports injuries and sport traumatology including established applications and new technical advances. US is presented both in its comparison to other imaging modalities and as a sole diagnostic tool. RESULTS AND CONCLUSION: US can be used for initial diagnosis to improve the clinical examination and for intensive short-term follow-up imaging. The main areas of application are currently the diagnosis of acute muscle and tendon injuries as well as overuse injuries. In particular, the exclusion of structural muscle injuries can be adequately ensured with US in the majority of anatomical regions. The recently published guideline on fracture ultrasound has strengthened the clinical evidence in this area, especially in comparison to conventional radiography and in the development of algorithms and standards. The increasing use of mobile ultrasound equipment with adequate image quality makes US a location-independent modality that can also be used at training sites or during road games. KEY POINTS: · Typically used for quick, focused initial diagnostic assessment and short-term follow-up after injury. · Mobile US devices allow increased use in training centers and training camps. · New US applications (SWE, 3 D) increase standardization in follow-up of tendon injuries. · Targeted use of US for musculoskeletal diagnostic assessment saves money and frees up capacity. CITATION FORMAT: · Lerchbaumer MH, Perschk M, Gwinner C. Ultrasound in sports traumatology. Fortschr Röntgenstr 2023; DOI: 10.1055/a-2185-8264.

6.
Cancers (Basel) ; 15(20)2023 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-37894402

RESUMO

BACKGROUND: Enlarged cervical lymph nodes (CLNs) can result from infection or malignancies, and a definitive diagnosis requires histological examination. Ultrasound (US) remains the first-line imaging modality for detection, and new US techniques may improve characterization. The aim of our study was to investigate whether the qualitative assessment of multiparametric US (mpUS) can improve diagnostic performance in the differentiation of benign and malignant CLNs. METHODS: 107 CLNs in 105 patients were examined by preoperative mpUS consisting of B-mode US, color-coded duplex sonography (CCDS), shear wave elastography (SWE) and contrast-enhanced US (CEUS). US images were evaluated in consensus by two experienced US operators. Histopathological examination was used as reference standard. RESULTS: SWE and CEUS combined showed the highest overall diagnostic performance (91% sensitivity, 77% specificity, 87% positive predictive value (PPV), 83% negative predictive value (NPV), 90% accuracy, χ2 (1) = 51.485, p < 0.001) compared to B-mode US and CCDS (87% sensitivity, 44% specificity, 73% PPV, 65% NPV, 73% accuracy χ2 (1) = 12.415, p < 0.001). In terms of individual techniques, SWE had higher specificity than B-mode and CCDS (71% sensitivity, 90% specificity, 92% PPV, 64% NPV, 78% accuracy, χ2 (1) = 36.115, p < 0.001), while qualitative CEUS showed the best diagnostic performance of all investigated US techniques (93% sensitivity, 85% specificity, 91% PPV, 87% NPV, 90% accuracy, χ2 (1) = 13.219, p < 0.001). Perfusion patterns, homogeneity, presence of necrosis, and malignancy differed significantly between malignant and benign CLNs (p < 0.001). CONCLUSIONS: SWE and CEUS can facilitate the differentiation of inconclusive CLNs when performed to supplement B-mode US and CCDS. MpUS may thus aid the decision between surgery and a watch-and-scan strategy in enlarged CLNs.

7.
Diagnostics (Basel) ; 13(18)2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37761324

RESUMO

Shear Wave Elastography (SWE) is currently used to detect tissue pathologies, i.e., tendinopathy. For preventive medicine, it is important to examine the sensitivity of SWE and to investigate how stiffness measures are affected by methodological variables. The aim of this study is to examine shear wave elastography (SWE) measures in order to compare the pre- and post-running values and to determine the correlation between the shear wave speed values (m/s). SWE examinations of the Achilles tendon (AT), soleus muscle (MS) and gastrocnemius muscle (MG)) were performed in 24 healthy professional female athletes. Measurements of the shear wave speed (m/s) were taken before and after incremental treadmill running until exhaustion. Correlations were investigated using the Pearson correlation coefficient and were examined for significance using the Student's t-test. The pre- and post-exercise shear wave speed did not differ. The pre-exercise and post-exercise stiffness for MS (r = 0.613), MG (r = 0.609) and AT (r = 0.583) correlated strongly. The pre-exercise values and changes in stiffness showed a significant correlation (p < 0.001). In professional athletes, acute exercise induces different tissue stiffness changes in AT, MS and MG for each individual. Thus, exercise activity immediately prior to the SWE measurement needs to be factored in when evaluating tissue stiffness.

8.
Diagnostics (Basel) ; 13(15)2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37568903

RESUMO

BACKGROUND: Injuries of the patellar tendon commonly occur as a result of mechanical loading of the tendon during physical activity. Shear wave elastography (SWE) is an established technique for assessing tendon stiffness, and has good interindividual reliability. The aim of this study was to investigate the impacts of physical parameters and different sports on patellar tendon stiffness in professional athletes using SWE. METHODS: Standardized patellar tendon SWE was performed in a relaxed supine position with a small roll under the knee (20° flexion) in 60 healthy professional athletes (30 female, 30 male). Multiple linear regression was performed for patellar tendon stiffness including gender, age, body mass index (BMI), and type of sport. RESULTS: Patellar tendon stiffness showed no significant difference between female (3.320 m/s) and male (3.416 m/s) professional athletes. Mean age (female: 20.53 years; male: 19.80 years) and BMI (female: 23.24 kg/m2; male: 23.52 kg/m2) were comparable. Female professional athletes with oral contraceptive (OC) intake showed higher patellar tendon stiffness than athletes without OC intake (3.723 versus 3.017; p = 0.053), but not significantly. CONCLUSION: In professional athletes, there are no significant differences in patellar tendon stiffness according to gender, age, BMI and type of sport (handball, volleyball, soccer, sprint, hammer throw). Oral contraceptives may not have an impact on patellar tendon stiffness in female athletes. Further studies are necessary.

9.
J Clin Med ; 12(8)2023 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-37109299

RESUMO

BACKGROUND: Shear wave elastography (SWE) is currently used to detect tissue pathologies and, in the setting of preventive medicine, may have the potential to reveal structural changes before they lead to functional impairment. Hence, it would be desirable to determine the sensitivity of SWE and to investigate how Achilles tendon stiffness is affected by anthropometric variables and sport-specific locomotion. METHODS: To investigate the influence of anthropometric parameters on Achilles tendon stiffness using SWE and examine different types of sports to develop approaches in preventive medicine for professional athletes, standardized SWE of Achilles tendon stiffness was performed in 65 healthy professional athletes (33 female, 32 male) in the longitudinal plane and relaxed tendon position. Descriptive analysis and linear regression were performed. Furthermore, subgroup analysis was performed for different sports (soccer, handball, sprint, volleyball, hammer throw). RESULTS: In the total study population (n = 65), Achilles tendon stiffness was significantly higher in male professional athletes (p < 0.001) than in female professional athletes (10.98 m/s (10.15-11.65) vs. 12.19 m/s (11.25-14.74)). Multiple linear regression for AT stiffness did not reveal a significant impact of age or body mass index (BMI) (p > 0.05). Subgroup analysis for type of sport showed the highest AT stiffness values in sprinters (14.02 m/s (13.50-14.63)). CONCLUSION: There are significant gender differences in AT stiffness across different types of professional athletes. The highest AT stiffness values were found in sprinters, which needs to be considered when diagnosing tendon pathologies. Future studies are needed to investigate the benefit of pre- and post-season musculoskeletal SWE examinations of professional athletes and a possible benefit of rehabilitation or preventive medicine.

10.
Radiol Case Rep ; 18(5): 1968-1972, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36970239

RESUMO

Peliosis hepatis remains a rare focal liver lesion with inconclusive imaging features. The unknown pathogenesis represents a wide possible range of etiologies including the breakdown of the sinusoidal borders, a potential hepatic outflow obstruction or dilatation of the central vein of a hepatic lobule. In histopathology, a blood-filled cystlike appearance with sinusoidal dilatation was reported. On ultrasound, B-mode features are not specific demonstrating a irregular, moreover hypoechogenic focal liver lesions. Postcontrast imaging features on Contrast-Enhanced-Ultrasound may mimic a malignant lesion with irregular contrast inflow and washout during late phase. Our case demonstrates a peliosis hepatis with malignant image features on contrast-enhanced ultrasound, ruled out by PET-CT and core needle biopsy with corresponding histopathological workup.

11.
Diagnostics (Basel) ; 12(10)2022 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-36292143

RESUMO

BACKGROUND: While adolescents have specific risk factors for acute and chronic injury, there is a lack of preventive medicine algorithms for this vulnerable group. Shear wave elastography (SWE) is currently mainly used for assessing muscle and tendon stiffness in adult athletes and can diagnose tissue pathologies such as tendinopathy. The aim was to investigate differences in quadriceps tendon and muscle stiffness between adolescent and adult professional soccer players using SWE and identify lateral imbalances in order to improve the knowledge of preventive medicine algorithms for professional adolescent athletes. METHODS: Standardized SWE examinations of both lower limb tendons and muscles (the quadriceps tendon (QT) and the vastus medialis (VM) muscle) in the longitudinal plane and relaxed tendon position were performed in 13 healthy adolescent soccer athletes (13-17 years), and a control group of 19 healthy adult professional soccer athletes (18-29 years). RESULTS: Adolescent soccer players had lower stiffness values for both the quadriceps tendon (3.11 m/s vs. 3.25 m/s) and the vastus medialis muscle (1.67 m/s vs. 1.71 m/s) than adult athletes. Moreover, QT stiffness in adolescent soccer players was significantly lower on the right side (QT: adult 3.50 m/s (2.73-4.56) vs. adolescent 2.90 m/s (2.61-3.12); p = 0.031). Analysis of the lateral differences revealed softer QT and VM tissue on the right side in over two-thirds of adolescent soccer athletes. Over two-thirds of adults had stiffer QT and VM tissue on the right side. CONCLUSION: In adolescent soccer players, the stiffness of the QT and VM muscle measured by SWE is lower in the right leg. SWE of the musculoskeletal system may thus become a relevant diagnostic tool to detect early lateral imbalances as a main risk factor for injury and may thus contribute to the prevention of acute and chronic injury prevention in adolescent athletes.

12.
J Clin Med ; 11(15)2022 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-35955971

RESUMO

Calcineurin inhibitors (CNIs) have improved short-term kidney allograft survival but are nephrotoxic and vasoconstrictive. Vasoconstriction is potentially reversible after switching from CNIs to belatacept. The kidney allograft shows optimal requirements for dynamic perfusion imaging using contrast-enhanced ultrasound (CEUS). We performed standardized CEUS in patients after switching from CNIs to belatacept for clinical indication to study the suitability of CEUS, in order to assess the effects of CNI cessation on kidney allograft perfusion. Eleven kidney transplant patients were enrolled from February 2020 until November 2020. Demographic, clinical, and laboratory parameters, as well as perfusion imaging, were assessed at baseline and 6 months after switching immunosuppression. Quantification of perfusion imaging on CEUS was performed using a post-processing software tool on uncompressed DICOM cine loops. After CNI cessation, estimated glomerular filtration rate increased by 4.8 mL/min/1.73 m2 (16%). Despite good quality of fit and comparable regions of interest in baseline and follow-up CEUS examinations, quantification of perfusion imaging showed a slightly improved cortical perfusion without reaching statistical significance after CNI cessation. This is the first study that systematically investigates the suitability of CEUS to detect changes of microvascular perfusion in kidney transplant recipients in vivo. No significant differences could be detected in perfusion measurements before and after CNI cessation.

13.
Rofo ; 194(12): 1322-1332, 2022 12.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-35850139

RESUMO

BACKGROUND: Ultrasound (US) is widely used as a fast and cost-efficient first-choice imaging technique without relevant side effects for a variety of diagnostic tasks. Due to technical advances, more complex and sophisticated methods such as color-coded duplex ultrasound, image fusion, contrast-enhanced ultrasound (CEUS), and ultrasound-guided interventions have become increasingly important in diagnostic algorithms. METHOD: This study presents an overview of all aspects regarding the establishing of an interdisciplinary US center based on five representative examples in Germany. These aspects include topics of ultrasound education, research, economics, and administration. RESULTS: The goal of an interdisciplinary US center is to bundle the use of equipment, staff, rooms, and infrastructure resources (optimization of equipment availability and use of new techniques) to expand the range of examinations, to promote resident training, and to boost continuing medical education of residents. This should result in better patient care and has additionally improved patient care while considering the added value for the participating institutions involved. Interdisciplinary US centers allow a reduction of the number of US devices needed in a hospital and more efficient use of available equipment through bedside time optimization by central organization within interdisciplinary management. The focused application of special US techniques such as CEUS or image fusion for complex, difficult interventions as well as the training and education of younger colleagues in using these techniques is centrally organized by experts and can be improved through the multidisciplinary experience available. CONCLUSION: Organizational structures, sharing of materials, and standardization of diagnostic reports facilitate and accelerate cooperation with the referring specialty. KEY POINTS: · Interdisciplinary US centers foster clinical collaboration, research, and jointly organized, standardized training.. · Economic aspects include optimization of available equipment, use of the latest US techniques, and centralization of organizational structures.. · Common terminology and standardized reporting increase the satisfaction of referring doctors. CITATION FORMAT: · Clevert DA, Jung EM, Weber M et al. Concepts in the Establishment of Interdisciplinary Ultrasound Centers: The Role of Radiology. Fortschr Röntgenstr 2022; 194: 1322 - 1332.


Assuntos
Radiologia , Humanos , Radiologia/educação , Ultrassonografia , Radiografia , Alemanha , Relatório de Pesquisa
14.
Clin Hemorheol Microcirc ; 82(1): 75-83, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35662110

RESUMO

BACKGROUND: B-Mode and Doppler ultrasound are standard diagnostic techniques for early postoperative monitoring and long-term follow-up of kidney transplants. In certain cases, contrast-enhanced ultrasound (CEUS) is used to clarify unclear Doppler findings. OBJECTIVE: To investigate the diagnostic performance of CEUS in the workup of renal allograft pathologies. METHODS: A systematic search for CEUS examinations of renal transplants conducted in our department between 2008 and 2020 was performed using the following inclusion criteria: i) patient age ≥18 years and ii) confirmation of diagnosis by biopsy and histopathology, imaging follow-up by CEUS, contrast-enhanced computed tomography (ceCT), contrast-enhanced magnetic resonance imaging (ceMRI), or angiography, or intraoperative findings. Exclusion criteria were: i) CEUS performed in the setting of a study and ii) CEUS for other indications than dedicated renal transplant examination. Statistical analysis was performed separately for subgroups with different indications (focal vs non-focal). RESULTS: Overall, 78 patients were included in the statistical analysis, which revealed high sensitivity (92.2%, 95% -confidence interval [CI] 81.5-96.9%) and high specificity (88.9%, 95% -CI 71.9-96.1%) of CEUS. CONCLUSIONS: The high diagnostic performance demonstrated here and the superficial location of kidney allografts advocate the additional use of CEUS in the follow-up of renal transplant recipients.


Assuntos
Meios de Contraste , Transplante de Rim , Adolescente , Aloenxertos/diagnóstico por imagem , Humanos , Rim/diagnóstico por imagem , Rim/patologia , Transplante de Rim/métodos , Centros de Atenção Terciária , Ultrassonografia/métodos
15.
Diagnostics (Basel) ; 13(1)2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36611304

RESUMO

OBJECTIVE: The preoperative diagnostical differentiation of parotid gland tumor (PGT) is not always simple due to several different entities. B-mode-ultrasound (US) remains the imaging modality of choice, while histopathology serves as the gold standard for finalizing the diagnosis. We aimed to evaluate the use of multiparametric US (mpUS) in the assessment of PGT. METHODS: We included 97 PGTs from 96 patients. A standardized mpUS protocol using B-mode-US, shear-wave elastography (SWE), and standardized contrast-enhanced ultrasound (CEUS) was performed prior to surgical intervention. SWE was assessed by real-time measurement conducting a minimum of five measurements, while quantitative CEUS parameters were assessed with a post-processing perfusion software. RESULTS: SWE allowed differentiation between benign PGT (Warthin's Tumor (WT) paired with lymph nodes (LN) and pleomorphic adenoma (PA)), and WT and LN were softer compared to PA. WT showed lower velocities than squamous cell carcinoma (SCC): the most common malignant PGT. CEUS parameters showed significant group differences between WT and PA, WT and malignant lesions, WT and SCC, WT paired with LN versus PA, and WT paired with LN versus SCC. CONCLUSION: MpUS seems to be beneficial in the assessment of PGT characterization, with benign PGT appearing to be softer in SWE than tumors with malignant tendencies. The quantitative CEUS parameter shows higher perfusion in WT than in PA, and malignant PGTs are less vascularized than WTs.

16.
J Ultrason ; 21(86): e244-e247, 2021 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-34540280

RESUMO

The aim of this case report is to present real-time CEUS-guided biopsy for diagnosing rare benign splenic pathologies after inconclusive findings on cross-sectional imaging. We present the case of a 50-year-old male patient who received a contrast-enhanced computed tomography scan of the thorax during the evaluation for lung transplant due to lung fibrosis, with incidental finding of disseminated hypodense splenic lesions. During follow-up imaging, the patient did not tolerate a complete MRI examination, and two acquired pulse sequences did not confirm the final diagnosis. While CT-guided biopsy revealed no results, CEUS-guided target biopsy with repeated contrast injections showed a benign littoral cell angioma of the spleen. The use of real-time CEUS-guided target biopsy during lesion washout may be a useful tool to improve the accuracy of biopsy and accelerate the diagnosis in patients with parenchymal lesions after inconclusive cross-sectional imaging findings which may pose a challenge for CT-guided biopsy.

17.
Radiologe ; 61(Suppl 1): 11-18, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34327554

RESUMO

BACKGROUND: Ultrasound (US)-guided biopsy is widely used for the diagnostic confirmation of focal lesions. For sampling of prostate tissue, magnetic resonance imaging (MRI)/US fusion-guided biopsy has already been implemented in routine clinical practice and has shown a superior detection rate of significant prostate cancer in risk assessment compared with standard systematic biopsy. Newer three-dimensional software tools with volumetric mapping of the prostate and biopsy core channels provide a better overview of systematic biopsy and thus contribute to more accurate treatment planning. Automatic fusion is a time-saver and can reduce potential examiner errors through greater standardization of the fusion process itself. METHODICAL INNOVATIONS: In abdominal pathologies, US fusion biopsy can improve the rate of successful tissue sampling by using fused imaging to target lesions that are barely visible or difficult to delineate on B­mode US scans. In addition, solid portions within larger tumors with enhancement on contrast-enhanced US can be targeted selectively, thereby avoiding sampling of necrotic areas and improving the quality of tissue cores for histopathological work-up. CONCLUSION: Especially in complex situations, use of US fusion not only saves time but also improves sampling accuracy, which in turn reduces the rate of insufficient tissue specimens that necessitate repeat biopsy.


Assuntos
Biópsia , Humanos
18.
Ultrasound Med Biol ; 47(10): 2869-2879, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34303559

RESUMO

Currently, there is no established technique to directly measure extrinsic tongue muscle activation during selective hypoglossal stimulation therapy (sHNS) in patients with obstructive sleep apnea syndrome (OSAS) in a simple, non-invasive clinical setting. Ultrasound shear-wave elastography (US-SWE) enables quantitative measurement of tissue stiffness. We investigated whether US-SWE is able to detect changes in muscle stiffness of the tongue during sHNS. Patients with OSAS treated with sHNS were prospectively enrolled. A standardized US-SWE protocol was used to selectively measure tissue stiffness of the geniohyoid muscle (GH) and genioglossus (GG) muscles on the side of stimulator implantation (sGH, sGG) and on the contralateral side (nGH, nGG) without and with sHNS. Eighteen patients were included (median age = 62 years, interquartile range: 56-65, 83.3% male). Median shear-wave velocity (SWV) increased during contraction with each patient's clinically prescribed therapeutic regimen in the sGH (+19%, p = 0.020) and sGG (+81%, p < 0.001) and decreased during contraction in the nGH (-8%, p = 0.107) and nGG (-8%, p = 0.396). Differences in SWV during contraction were significant only on the side of stimulation (sGG +81%, sGH +19%). SWE measurements had excellent reliability as reflected by a Cronbach α value ≥0.9 for all target muscles pre- and post-contraction and an item-total correlation ≥0.5. US-SWE allows reliable measurement of SWV as an indicator of muscle stiffness of extrinsic tongue muscles. This non-invasive method provides new possibilities to distinguish and characterize responders from non-responders in hypoglossal stimulation therapy. Compared with the regular visual assessment of tongue movement, US-SWE of individual muscle groups provides a new non-invasive imaging tool in patients with OSAS.


Assuntos
Técnicas de Imagem por Elasticidade , Apneia Obstrutiva do Sono , Feminino , Humanos , Nervo Hipoglosso/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Apneia Obstrutiva do Sono/diagnóstico por imagem , Apneia Obstrutiva do Sono/terapia , Língua/diagnóstico por imagem
20.
Clin Hemorheol Microcirc ; 78(3): 259-269, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33646144

RESUMO

BACKGROUND: Tissue Doppler imaging (TDI) uses the Doppler principle to quantify the movement of biological tissues. OBJECTIVE: To investigate the contribution of TDI parameters derived during magnetic resonance imaging and ultrasound (MRI/US) fusion-guided biopsy for prostate cancer (PCa) discrimination. METHODS: From March 2016 to Dec. 2018, 75 men with suspected PCa prospectively underwent fusion-guided prostate biopsy. TDI overlaid on predefined target lesion were compared to the confirmed contralateral tumor-free area of the prostate gland (using Image J). Diagnostic value of TDI parameters was assessed using histopathology as standard of reference. RESULTS: Thirty-seven patients were diagnosed with PCa (49.3%), among them 27 with clinically significant PCa (Gleason score >  3 + 3 = 6 (ISUP 1). The LES/REF ratio was lower in confirmed PCa patients compared to patients without PCa (0.42, IQR, 0.22-0.59 vs. 0.52, IQR, 0.40-0.72, p = 0.017). TDI parameters allowed differentiation of low-risk from high-to-intermediate-risk PCa (ISUP 2 versus ISUP 3) based on lower pixel counts within the target ROI (1340, IQR 596-2430 vs. 2687, IQR 2453-3216, p = 0.004), lower pixel percentage (16.4 IQR 11.4-29.5 vs. 27.3, IQR 22.1-39.5; p = 0.005), and lower LES/REF ratios (0.29, IQR 0.19-0.51 vs. 0.52, IQR 0.47-0.74, p = 0.001). CONCLUSION: TDI of prostate lesions prelocated by MRI discriminates between cancerous and noncancerous lesions and further seems to enable characterization of PCa aggressiveness. This widely available US technique may improve confidence in target lesion localization for tissue sampling.


Assuntos
Biópsia Guiada por Imagem , Neoplasias da Próstata , Humanos , Imageamento por Ressonância Magnética , Masculino , Gradação de Tumores , Neoplasias da Próstata/diagnóstico por imagem , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...