Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Orthop Relat Res ; 473(3): 928-35, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24832828

RESUMO

BACKGROUND: Biofilm-related periprosthetic infections are catastrophic to patients and clinicians. Data suggest the addition of vitamin E to UHMWPE may have the ability to reduce biofilm formation on the surface of UHMWPE; however, previous studies were performed using stagnant broth solutions that may not have simulated a physiologic environment. In addition, the observed differences in levels of bacterial attachment, though statistically significant, may not be clinically significant. QUESTIONS/PURPOSES: We blended vitamin E with UHMWPE material and tested it for the ability to resist biofilm formation using a clinical isolate of methicillin-resistant Staphylococcus aureus (MRSA). Three additional materials were tested for comparison: highly crosslinked UHMWPE, compression-molded UHMWPE, and polyetheretherketone. We also determined whether the surface roughness of these materials facilitated biofilm formation. METHODS: Using a flow cell system, samples of each material type were placed into separate chambers. A 10% solution of brain-heart infusion broth containing 10(5) colony-forming units (CFUs)/mL was flowed through the flow cell over 48 hours. The number of bacteria that adhered to the surface was quantified and biofilm formation was observed qualitatively using scanning electron microscopy. Optical profilometry was used to determine the surface roughness of each material type. RESULTS: Vitamin E-blended UHMWPE did not reduce biofilm formation of a clinically relevant strain of MRSA compared to materials that did not have vitamin E. More specifically, vitamin E-blended materials had similar amounts of biofilm formation (~ 8 log10 CFUs/cm(2)) compared to materials not containing vitamin E (~ 8.1 log10 CFUs/cm(2)) (p > 0.4). The roughness of vitamin E-blended material surfaces (mean ± SD: 1.85 ± 0.46 µm) compared to that of materials without vitamin E (2.06 ± 1.24 µm) did not appear to influence biofilm formation. CONCLUSIONS: Under physiologically relevant conditions, vitamin E-blended UHMWPE did not have the ability to reduce the formation of biofilms by MRSA. CLINICAL RELEVANCE: These data indicate that the addition of vitamin E to UHMWPE may not reduce clinically relevant rates of biofilm-related periprosthetic infections of total joint arthroplasty devices.


Assuntos
Biofilmes/efeitos dos fármacos , Teste de Materiais , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Polietilenos/química , Infecções Relacionadas à Prótese/prevenção & controle , Vitamina E/química , Materiais Biocompatíveis , Biofilmes/crescimento & desenvolvimento , Humanos , Staphylococcus aureus Resistente à Meticilina/crescimento & desenvolvimento , Infecções Relacionadas à Prótese/tratamento farmacológico , Vitamina E/farmacologia , Vitamina E/uso terapêutico
2.
Antimicrob Agents Chemother ; 58(4): 2400-4, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24395238

RESUMO

Implant-related infections are becoming increasingly difficult to treat due to the formation of biofilms on implant surfaces. This study analyzed the in vitro efficacy of a novel antimicrobial coating against biofilms of Pseudomonas aeruginosa, using a flow cell system. Results indicated that P. aeruginosa biofilms were reduced by greater than 8 log10 units in less than 24 h. Data indicated that this active-release coating may be promising for preventing biofilm implant-related infections.


Assuntos
Anti-Infecciosos/farmacologia , Biofilmes/efeitos dos fármacos , Pseudomonas aeruginosa/efeitos dos fármacos , Próteses e Implantes/microbiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...