1.
Sci Rep ; 14(1): 14933, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38942810

RESUMO

This study proposes a protection relay using a microcontroller to detect and classify faults in transmission lines based on the wavelet transform. An experimental model was constructed from an actual 115 kV transmission system prototype. The current signal was observed based on the fault type, phase, and position. Clark's transform and the discrete wavelet transform (DWT) were applied to transform signals for analysis. Moreover, the performance of fault detection based on the output signals of Clark's transform (alpha sequence, beta sequence, and zero sequence current) was compared to the performance of the alternative proposed fault detection method, which is based on the combining factor between alpha and beta sequence current. In addition, the influence of DWT level on fault analysis is also considered and is used to confirm the accuracy of fault detection. Results show that the proposed method is efficient for fault detection and classification. This finding allows the researcher to choose the appropriate analytical method. Moreover, it can also be used as the basis for overcurrent relay algorithm design in the effort to develop more advanced technologies.

2.
Heliyon ; 9(3): e14589, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36994389

RESUMO

The protection of traditional high voltage capacitor banks relies on an unbalance relay which operates when an internal fuse is blown. However, the unbalance relay cannot indicate cause or position of the fault. Thus, an operator wastes time and human resources investigating the fault issues. To address this issue, a method to locate the fault position in a capacitor bank is developed in this study. The study was simulated by using PSCAD software and modeled on the 115-kV system of the Electricity Generating Authority of Thailand (EGAT). Case studies involving faults with varied phases, side and branch connections, row connections, and inception angles were considered. Moreover, the magnitude and argument of the current phase and unbalanced current were analyzed to identify the fault location in a capacitor bank. The performance of the proposed method was verified via comparison with that of traditional methods and the results of laboratory experiments. In addition, various voltage systems were observed to verify the flexibility and accuracy of the proposed method. The results demonstrate that the proposed method was more efficient than traditional methods at locating the fault position in a capacitor bank.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...